Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF FEBRUARY 9,1999 PSA#2279

Directorate Of Contracting/Oo-Alc Pko, 6038 Aspen Avenue Bldg 1289 Ne, Hill air Force Base, Ut 84056-5000

66 -- BEAM CENTERLINE SOL F42650-99-R-A073 DUE 032999 POC For copy, PKOA/Evelyn Stoltz/(FAX)801-777-6528, For additional information contact Nadine Birt/Pkosc/[801]775-2377 WEB: Click here to obtain/view solicitation., http://contracting.hill.af.mil/html/5099ra073/comm5099ra073.htm. E-MAIL: Click Here to E-mail Buyer*****, birtn@wpos.hill.af.mil. Total length of the line shall not exceed 6 meters and shall include the following components: A. Prebuncher (1) operating frequency 1282.8 Mhz (2) operating temperature 40 degrees celsius (30 to include RF coupler to extract RF power fro Klystron #1, and phase adjuster. B. Injection focusing magnets C. Accelerator sections (2 ea) 1. operating frequency 1282.8 Mhz 2. operating temperature 40 degrees celsius 3. RF input power 30 Mw (each section) 4. Maximum beam energy 30 MeV (with 2 sections) 5. Peak beam current in transient mode (10 to 50 nanoseconds) 20A and 6. Beam current in steady state mode (t0 100 microseconds) 1A at 15 MeV (with 2 sections) D. RF windows (4 ea) E. Helmholtz focusing coils (as required) F. Eam energy analyzer and bending magnet (1) capable of 5 MeV to 30 MeV beam energy range G. Beam exit port windows H. Beam current monitors (2 ea) The following items will be furnished by OO-ALC 1. WR-650 wave guide components 2. RF loads 3. Directional couplers for power and VSWR monitoring 4. Arc monitors at accelerator wave guide windows 5. High vacuum system (a) Ion pumps (b) Roughing pump (c) Manifolds and valves 6. Cooling Water System (a) circulating pump (b) temperature control system (c) manifolds and valves 7. Power supplies for helmholtz coils, steering magnets, and focusing magnets. 8. Support structure Delivery: 180 days after receipt of order The approximate issue/response date will be 25 FEB 1999. No telephone requests. Only written or faxed requests received directly from the requestor are acceptable. All responsible sources solicited may submit a bid, proposal, or quotation which shall be considered. An Ombudsman has been appointed to hear concerns from offerors or potential offerors during the proposal development phase of this acquisition. The purpose of the Ombudsman is not to diminish the authority of the program director or contracting officer, but to communicate contractor, concerns, issues, disagreements, and recommendations to the appropriate government personnel. When requested, the Ombudsman will maintain strict confidentiality as to the source of the concern. The Ombudsman does not participate in the evaluation of proposals or in the source selection process. Interested parties are invited to call Lt Col Allen H. Brody if your concerns are not satisfied by the contracting officer (801)777-6991. ATTENTION: Contractor must be registered with Central Contractor Registration to be eligible for contact award or payment from any DOD activity. Information on registration and annual confirmation requirements may be obtained by calling 1-888-227-2423, or via the Internet at http://ccr.edi.disa.mil Posted 02/05/99 (I-SN295729). (0036)

Loren Data Corp. http://www.ld.com (SYN# 0325 19990209\66-0009.SOL)


66 - Instruments and Laboratory Equipment Index Page