Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF FEBRUARY 19,1999 PSA#2286

Naval Research Laboratory, Code 3220, 4555 Overlook Ave. S.W., Washington, D.C. 20375-5326

66 -- DIGITAL FREQUENCY DISCRIMINATOR EQUIPMENT SOL N00173-99-R-CR02 DUE 031299 POC Alan W. Crupi, Contract Specialist, Code 3220.CR, (202) 767-3595; F. Janilea Bays, Contracting Officer, Code 3220.JB (202) 767-3595 E-MAIL: Click here to forward a request via e-mail, Synopsis@contracts.nrl.navy.mil. This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. This solicitation number, N00173-99-R-CR02, is issued as a request for proposal (RFP). The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 97-10 and for Defense Federal Acquisition Regulation Supplement (DFARS) through Defense Acquisition Circular 91-13. The FAR and DFAR provisions and clauses cited herein are incorporated by reference into this solicitation. This acquisition is unrestricted. The small business size standard for this acquisition is 100 employees and the standard industry code (SIC) is 5049. Contract Line Item Number (CLIN) 0001: Digital Radio Frequency Memory consisting of baseband, fast local oscillator and 500 MHz instantaneous bandwidth, one (1) each. The new equipment must meet or exceed the following specifications: RF input frequency band must be between 2.4 to 5.4 GHz, Instantaneous Bandwidth: 500 MHz, Input Band Select Method: Auto Internal Select/External, Sub-band set-on time: 20 nsec maximum, RF input signal range: -35 to +15 dBm, RF input VSWR: 2.0:1 or better, Phase sampling: 3 bits minimum, Phase correction: 45 degrees minimum, Recirculation PW: 3.2 msec maximum, RF memory length: 204 usec minimum, Delay resolution: 50 nsec minimum, Number of memory files: at least 4 (each with independent delay timing), File output conflict resolution: File 1 must have priority over Files 2,3,4 -- File 2 must have priority over Files 3,4 -- File 3 must have priority over File 4, Spurious/Harmonics output levels: -10 dBc 100% of band, RF output frequency band: must be between 2.4 to 5.4 GHz, RF output power level: -4.5 to -1.0 dBm, Output switch isolation: 50 dB minimum, Output switch speed: 15 nsec maximum, Minimum I/O interface requirements for computer and number of data lines/type: Reset: 1 input, Bypass: 1 input, Write enable: 1 input, Write to file: 2 input, Output blanking: 1 input, Write busy: 4 output, Recall busy: 4 output, RF output active: 1 output, Signal present: 1 output, 10 MHz clock P1 (derived from memory word clock): 1 output, 10 MHz clock P2 (45 degree phase difference from P1 clock): 1 output, the mount platform must be VME, Digital power connectors (3 each): DIN 41612 type C, 96 contacts or commercial compatible, RF connectors (2 each): SMA (sub miniature type A), Operating temperature: -20 to +65 degrees C, Set-up interface: IP-Bus/Parallel, DC Power requirements: (+5V/5.0 Amps maximum, -5V/13.0 Amps maximum, +12V/2.0 Amps maximum, -12V/1.0 Amps maximum, -2V/2.0 Amps maximum), Physical dimensions not to exceed: 9.0 x 6.7 x 3.7 inches, Interface PWB features: (Parameter (I/O interface to computer) and number of data lines/type): Data: 16 bi-directional, Address: 7 inputs, Strobe: 1 input,Read/Write: 1 input, Recall Enable: 1 input, Recall file: 2 inputs, Number of false targets per file: eight (8), Maximum delay per target: 3.0 msec, Delay resolution for false targets: 50 nsec. Contract Line Item Number (CLIN) 0002: Digital Frequency Discriminator one (1) each must meet or exceed the following specifications: Operating frequency: 6.0 Ghz to 18.0 Ghz, Unambiguous bandwidth: minimum of 12288 Mhz, Mean frequency resolution: minimum of 1.5 Mhz, Binary zero frequency: must have 5866.5 Mhz, (@ Cell Center), Read modes: Internal/External, RF throughput time between RF leading edge and data ready (internal): maximum of 250 nsec, RF pulse width: (full performance) minimum of 100 ns to CW, (limited performance) minimum of 50 ns, Input dynamic range: -55 dbm to +10 dbm, RMS accuracy: maximum of 2.5 Mhz, Peak frequency accuracy: maximum of 8.25 Mhz, Signal to noise ratio: 2.0 db (max), Input VSWR: 2.00:1 max, Operating temperature (baseplate): -20 C to +65 C, Logic requirements: (Input) Read Select, External Read, FM Enable, Data Acknowledge, (Output) Signal Present, Data Ready, 13 Bit Frequency Word, CW Alarm, POCW Alarm and Frequency Valid. Maximum Power: Voltage +15 VDC (+/-5%) / Drain 1.5 Amps max, Voltage -15 VDC (+/-5%) / Drain 0.5 Amps max, Voltage +5.0 VDC (+/-5%) / Drain 1.5 Amps max, Voltage -5.2 VDC (+/-5%) / Drain 1.0 Amps max. Unit Connectors: Connector Designation: J1 / Function: Data control / Type: DCMM37PL or commercial compatible, Connector Designation: J2 / Function: Power / Type: DAMM15PL or commercial compatible, Connector Designation: J3 / Function: RF Input / Type: SMA Female or commercial compatible. A standard commercial warranty must be provided. Product documentation should be provided. The required delivery schedule for CLIN 0001 is no later than nine (9) months after contract award date. The required delivery schedule for CLIN 0002 is no later than seven (7) months after contract award date. The contractor shall deliver the system FOB Destination, Naval Research Laboratory, 4555Overlook Avenue, SW, Washington, DC 20375-5326. The FAR and DFAR provisions and clauses cited herein are incorporated by reference into this solicitation. Offerors are advised to propose in accordance with the provision at FAR 52.212-1 Instructions to Offerors -- Commercial Items. There are no addenda to the provision FAR 52.212-1. Offerors will be evaluated in accordance with FAR 52.212-2 Evaluation -- Commercial Items. The specific evaluation criteria under paragraph (a) of FAR 52.212-2 are: (1) technical capability of the item offered to meet NRL's need, (2) price and (3) past performance. Technical and past performance, when combined, are of equal importance compared to price. Offerors are advised to include with their offer a completed copy of the following provisions; FAR 52.212-3, Offeror Representations and Certifications -- Commercial Items, DFARS 252.212-7000, Offeror Representations and Certifications -- Commercial Items and DFARS 252.225-7000, Buy American Act -- Balance of Payments Program Certificate. The following FAR clauses apply to this solicitation: FAR 52.212-4, Contract Terms and Conditions -- Commercial Items with no addenda and FAR 52.212-5 Contract Terms and Conditions Required to Implement Statutes or Executive Orders -- Commercial Items. The additional clauses cited under FAR 52.212-5 that are applicable to this solicitation are: FAR 52.203-6 (Alt 1), FAR 52.219-8, FAR 52.219-9, FAR 52.219-25, FAR 52.219-26, FAR 52.222-26, FAR 52.222-35, FAR 52.222-36 and FAR 52.222-37. The clause at DFARS 252.212-7001 Contract Terms and Conditions Required to Implement Statutes Applicable to Defense Acquisitions of Commercial Items applies to this acquisition. The additional clauses cited under DFARS 252.212-7001 that are applicable to this acquisition are: DFARS 252.212-7001, DFARS 252.225-7001, DFARS 252.225-7012, DFARS 252.219-7003, DFARS 252.243-7002 and DFARS 252.247-7024. Any contract awarded as a result of this solicitation will be a DO rated order certified for national use under the Defense Priorities and Allocations System (DPAS) (15 CFR 700). Offers must be delivered to: Contracting Officer, Code 3220.CR, Building 222, Room 115A, Naval Research Laboratory, 4555 Overlook Avenue, SW, Washington, Dc 20375-5326. Offers must be received no later than 4:00 P.M. E.S.T. on 12 March 1999. The package must be identified as: RFP N00173-99-R-CR02, Closing Date: 3/12/99. For information regarding this solicitation contact Alan W. Crupi, Contract Specialist, at (202) 767-3595. Posted 02/11/99 (W-SN297389). (0042)

Loren Data Corp. http://www.ld.com (SYN# 0396 19990219\66-0004.SOL)


66 - Instruments and Laboratory Equipment Index Page