COMMERCE BUSINESS DAILY ISSUE OF MARCH 2,1999 PSA#2293SA-ALC/Contracting Directorate/LDKAA; 485 Quentin Roosevelt Road Suite
12; Kelly AFB, TX 78241-6419 66 -- ELECTRICAL TEST SET (FAULT LOCATOR) SOL F41608-99-R-31534 DUE
031799 POC The Point of Contact is Ron Du Pree, LDKAA, Phone:
210-925-8461, FAX: 210-925-2098, E-MAIL:
ronald.dupree@ldgate1.kelly.af.mil E-MAIL: Send your E-Mail request to
the POC, ronald.dupree@ldgate1.kelly.af.mil. The Governments plans to
make an award to a GSA contract for the a Cable Faut locator as
follows: CLIN 0001: Electrical Test Set (Cable Fault Locator), for a
common support/use with a transmitter and receiver, with built-in ohm
meter, voltage sensing measuring capability, displays earth fault
resistance, confirms far end ground and shield, P/N 2273-U3P3.
Incremental Quantities with discount breakouts of: 1 -- 20, 21- 40, and
41 -- 60 each. The best estimated buy quantity for the entire three
year period is 60 each with initial delivery of 1 each to European APO
and 13 each to Warner Robbins AFB, GA by Nov 99. Form, Fit, and
Functions: Item has a built-in ohm meter, voltage sensing measuring
capability, displays earth fault resistance, confirms far end ground
and shield. Receiver has a digital dept readout in inches or feet and
inches or centimeters. It measures current in cable and pin points
sheath fault and cable breaks. Receiver frequencies: are 577 Hz, 8 Khz,
33 Khz, and 200 Khz. Tone mode at577 Hz and 200 Khz pulsed at 8 Hz.
Dept Range: 0 15, Power by six akaline AA cells with a life of 80 Hrs.
Transmitter Output Frequencies: 577 Hz, 8 Khz, 33 Khz, 200 Khz. Output
Voltage: 75 VRMS Max. Size/Dimensions Receiver: 25.5 H X 3.75 W X 10.75
D Size/Dimensions Transmitter: 8.75 H X 11.25 W X 7.75 D Item is
basically described by its Part Number (2273-U3P3) This is a
competitive Brand Name (3M Dynatel) commercial item solicitation
announcement of which there are two qualified sources as follows: CAGE:
75037 -- Minnesota Mining and Mfg Co, Elect Prod Div, 3M Austin Ctr,
Austin, TX 78769-2963 CAGE: 1dy18 -- Colcom Inc, 15527 Ranch Rd 620 N,
Austin, TX 78717-5206 Evaluation of offers will be based on technical
capability and price. All potential offerors should contact the
buyer/PCO identified in this notice for additional information and/or
to communicate concerns, if any, concerning this acquisition. If your
concerns are not satisfied by the contracting officer, an Ombudsman has
been appointed to hear concerns from offerors or potential offerors
during the proposal development phase of an acquisition. The Ombudsman
does not diminish the authority of the program director or Contracting
Officer, but communicates Contractor concerns, issues, disagreements,
and recommendations to the appropriate Government personnel. When
requested, the Ombudsman shall maintain strict confidentially as to the
source of the concern. The Ombudsman does not participate in the
evaluation of proposals or in the source selection process. Interested
parties are invited to call the SA-ALC Acquisition Ombudsman at AC
210-925-5133 or send E-Mail to: ombudsman@www.kelly-afb.org. See
Note(s) 1 Posted 02/26/99 (D-SN302786). (0057) Loren Data Corp. http://www.ld.com (SYN# 0250 19990302\66-0002.SOL)
66 - Instruments and Laboratory Equipment Index Page
|
|