Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF MARCH 2,1999 PSA#2293

SA-ALC/Contracting Directorate/LDKAA; 485 Quentin Roosevelt Road Suite 12; Kelly AFB, TX 78241-6419

66 -- ELECTRICAL TEST SET (FAULT LOCATOR) SOL F41608-99-R-31534 DUE 031799 POC The Point of Contact is Ron Du Pree, LDKAA, Phone: 210-925-8461, FAX: 210-925-2098, E-MAIL: ronald.dupree@ldgate1.kelly.af.mil E-MAIL: Send your E-Mail request to the POC, ronald.dupree@ldgate1.kelly.af.mil. The Governments plans to make an award to a GSA contract for the a Cable Faut locator as follows: CLIN 0001: Electrical Test Set (Cable Fault Locator), for a common support/use with a transmitter and receiver, with built-in ohm meter, voltage sensing measuring capability, displays earth fault resistance, confirms far end ground and shield, P/N 2273-U3P3. Incremental Quantities with discount breakouts of: 1 -- 20, 21- 40, and 41 -- 60 each. The best estimated buy quantity for the entire three year period is 60 each with initial delivery of 1 each to European APO and 13 each to Warner Robbins AFB, GA by Nov 99. Form, Fit, and Functions: Item has a built-in ohm meter, voltage sensing measuring capability, displays earth fault resistance, confirms far end ground and shield. Receiver has a digital dept readout in inches or feet and inches or centimeters. It measures current in cable and pin points sheath fault and cable breaks. Receiver frequencies: are 577 Hz, 8 Khz, 33 Khz, and 200 Khz. Tone mode at577 Hz and 200 Khz pulsed at 8 Hz. Dept Range: 0 15, Power by six akaline AA cells with a life of 80 Hrs. Transmitter Output Frequencies: 577 Hz, 8 Khz, 33 Khz, 200 Khz. Output Voltage: 75 VRMS Max. Size/Dimensions Receiver: 25.5 H X 3.75 W X 10.75 D Size/Dimensions Transmitter: 8.75 H X 11.25 W X 7.75 D Item is basically described by its Part Number (2273-U3P3) This is a competitive Brand Name (3M Dynatel) commercial item solicitation announcement of which there are two qualified sources as follows: CAGE: 75037 -- Minnesota Mining and Mfg Co, Elect Prod Div, 3M Austin Ctr, Austin, TX 78769-2963 CAGE: 1dy18 -- Colcom Inc, 15527 Ranch Rd 620 N, Austin, TX 78717-5206 Evaluation of offers will be based on technical capability and price. All potential offerors should contact the buyer/PCO identified in this notice for additional information and/or to communicate concerns, if any, concerning this acquisition. If your concerns are not satisfied by the contracting officer, an Ombudsman has been appointed to hear concerns from offerors or potential offerors during the proposal development phase of an acquisition. The Ombudsman does not diminish the authority of the program director or Contracting Officer, but communicates Contractor concerns, issues, disagreements, and recommendations to the appropriate Government personnel. When requested, the Ombudsman shall maintain strict confidentially as to the source of the concern. The Ombudsman does not participate in the evaluation of proposals or in the source selection process. Interested parties are invited to call the SA-ALC Acquisition Ombudsman at AC 210-925-5133 or send E-Mail to: ombudsman@www.kelly-afb.org. See Note(s) 1 Posted 02/26/99 (D-SN302786). (0057)

Loren Data Corp. http://www.ld.com (SYN# 0250 19990302\66-0002.SOL)


66 - Instruments and Laboratory Equipment Index Page