COMMERCE BUSINESS DAILY ISSUE OF MARCH 11,1999 PSA#2300Military Sealift Command, Camp Pendleton, Bldg. 238, Virginia Beach, VA
23458 D -- INTEGRATED LARGE SCREEN DISPLAY SYSTEM SOL N32205-99-R-0007 DUE
032399 POC Jitendra Sharma, Contract Specialist 757-417-4605 & Sandra
Tyree, Contracting Officer 757-417-4591 E-MAIL: Contract Specialist,
jay.sharma@smtpgw.msc.navy.mil. Military Sealift Command, Atlantic is
requesting bids for the installation of an Integrated Large Screen
Display System in the Command and Control Center (CCC) of their new
Headquarters in building Z101, Norfolk Naval Base, Norfolk, Virginia.
The Integrated Large Screen Display System will be located in the
briefing area of the Command and Control Center. An equipment room is
located at one end of the briefing area and is configured for
rear-projection. This space has adequate 110/120V power available and
is suitable for equipment installation. A non-load bearing wall across
one end of the room currently contains a rear-projection screen which
may be removed and the wall modified as necessary. The Integrated
Large Screen Display System must be able to accept simultaneous input
from multiple signal sources including Non-secure LAN MS Windows NT4.0,
secure LAN MS Windows NT4.0, Cable and/or Satellite Television, and
Video Teleconferencing. The Cable and/or Satellite Television service
is to be procured and installed as part of the contract. All necessary
Video Teleconferencing equipment is to be included as part of the
installation and configured to be compatible with an existing "Freebon,
Inc." installation installed elsewhere in the building. It must be able
to display a minimum of five (5) individual, resizeable, "real-time"
displays within a seamless Large Screen Display area which will be
provided by the above listed sources. Military Sealift Command will
provide, if current systems are compatible, all necessary PC
workstations. All other equipment and integration software will be
provided by the selected contractor. The contractor must also provide
final system checkout, operator training, and all technical and
operational documentation. A minimum one year warranty on installation,
software, and all equipment is required. A maintenance contract
covering normal maintenance and emergency repair and/or replacement of
equipment is desired. Emergency repair response time must be
guaranteed at 8 hours or less. Companies desiring to view the
installation space and discuss requirements prior to submitting bid may
make appointments with the Command and Control Center Coordinator, Mr.
Bruce Moon, phne: (757)444-2377, DSN 564-2377, E-Mail:
Bruce.Moon@smtpgw.msc.navy.mil Posted 03/09/99 (W-SN306412). (0068) Loren Data Corp. http://www.ld.com (SYN# 0011 19990311\D-0001.SOL)