COMMERCE BUSINESS DAILY ISSUE OF MARCH 19,1999 PSA#23065460 South Quebec St., Suite 100, Englewood, CO 80111-1916 M -- PRIVATIZATION UNDER 10 USC 2688, UTILITY SYSTEMS: CONVEYANCE
AUTHORITY AT MACDILL AFB, FLORIDA DUE 041999 POC Scott Beckman or Joel
Theis, 303/771-3103 E-MAIL: E-mail to POC, sbeckman@talpart.com. The
Air Force seeks to identify responsible potential sources and obtain
information in regards to privatization of utility systems in
accordance with 10 USC 2688, "Utility Systems: Conveyance Authority".
The Commander of MacDill Air Force Base (AFB) is seeking interest and
information specifically for the potential privatization of the
electrical, natural gas, potable water, and wastewater utility systems
at MacDill AFB, Florida. OBJECTIVE: Should privatization result, the
ownership of the MacDill electrical, natural gas, potable water, and
wastewater utility systems, operation and maintenance and obligation to
continue to provide utility service for an indefinite and ongoing
period will transfer to a utility service provider. All responsibility
for maintaining reliable utility service, including such items as
environmental compliance, maintenance costs, major system renovations,
construction, equipment, manpower and overhead costs will become the
utility service provider's responsibility. It is intended that the
privatization will ultimately reduce the Air Force's life-cycle costs
for operating and maintaining utility systems and services. SYSTEM
DESCRIPTIONS: The following is provided only to give an approximation
of the size, scope and general description of the electrical, natural
gas, potable water, and wastewater utility systems. Any numbers should
only be used for estimating purposes. The following system parameters
are approximations: The base size is about 5,630 acres. This includes
624 buildings, and 623 family housing units. Electrical Distribution:
13,200 volt distribution system, one substation with two transformers
of 22.0 MVA and 28 MVA capacities respectively, total system capacity
of 50.0 MVA (Transformer Capacity). Approximate annual consumption:
438,000,000 KWh. Primary overhead distribution: approximately 60 Miles.
Primary underground distribution: approximately 25 Miles. Residential
Usage: 9.5% Commercial/Industrial Usage: 90.5%. Natural Gas
Distribution: Approximately 24 miles of distribution lines ranging from
8" main to 3/4" service laterals. Water Distribution: Average daily
use: 1.30 million gallons per day (FY 98). Peak daily use: 1.97 million
gallons per day (FY 98). Two elevated water storage tanks (1 @ 250,000
gallon, 1 @ 500,000 gallon). Approximately 70 miles of water
distribution lines ranging from 20" main down to 3/4" service laterals.
Waste Water Collection: One sewage treatment plant with capacity of 2.0
Million gallons per day. 62 lift stations. Approximately 17.5 miles of
sewer main ranging from 24" down to 6". Effluent sent to golf course
for irrigation, and several spray fields for evaporation. PROCEDURES:
This request to interested parties is for gathering information and is
a required component and systematic process to evaluate the interested
parties under the Air Force's utilities privatization program. In order
to minimize costs both to potentially interested parties and the
government, this notice is being issued to determine the interest and
feasibility ofproceeding with a formal request for proposals. Should
insufficient credible interest be identified for a privatization
action, it is highly likely that no formal solicitation will be issued.
SHOULD INTEREST BE DETERMINED SUFFICIENT, A FORMAL REQUEST FOR
PROPOSALS MAY BE FORTHCOMING. Small Business interests shall note the
FAR Part 19 Standard Industrial Codes (SIC) and Size Standards for the
utility systems identified in this announcement. Some, all, or any
combination of the following may apply. SIC/SS: 4911/4Million (M)
Megawatt hours, 4922/$5M, 4923/$5M, 4924/500, 4925/$5M, 4931/$5M,
4932/$5M, 4939/$5M, 4941/$5M, 4952/$5M, 4953/$6M, 4959/$5M, 4961/$9M,
4971/$5M. REQUESTED RESPONSE: Interested parties should provide a
statement of interest on company letterhead (not to exceed 20 pages in
length). The statement should include as a minimum the following
criteria: (1) capability and experience in ownership, operation and
maintenance of similar potable water and wastewater utility systems;
(2) financial capacity to purchase, expand and operate the utility
systems; (3) statement detailing the understanding of the obligation to
serve in regards to continuous utility service; (4) statement detailing
the legal right to serve, own, operate, and maintain utility systems
within state laws and an understanding of any applicable federal,
territorial and local utility laws, regulations or franchise
requirements affecting utilities in the territory, and capability of
complying with such requirements; and (5) statement detailing the
understanding of federal, territorial, and local environmental laws and
regulations and familiarity and experience with environmental
compliance procedures and regulations for the (State) and the U. S.
Environmental Protection Agency. Elaborate proposals or pricing
information is neither required nor desired. Under no circumstances
will cost data for the existing systems be provided. Any innovative and
new conceptual ideas to achieve the stated objective are encouraged. If
a site visit and the provision of additional data are later determined
necessary, notification will be provided by way of an amendment to
this announcement. It should be noted that RFIs for different utility
systems may be issued in the same time frame. A separate response to
each RFI is required. The point of contact is Scott Beckman or Joel
Theis, 303/771-3103 Posted 03/17/99 (W-SN309784). (0076) Loren Data Corp. http://www.ld.com (SYN# 0059 19990319\M-0001.SOL)
M - Operation of Government-Owned Facilities Index Page
|
|