COMMERCE BUSINESS DAILY ISSUE OF MARCH 25,1999 PSA#2310US ARMY CORPS OF ENGINERS, SACRAMENTO, CONTRACTING DIVISION, 1325 J
STREET, SACRAMENTO CA 95814-2922 46 -- WATER, PURIFICATION AND SEWAGE TREATMENT EQUIPMENT BEALE AFB, CA
SOL DACA05-99-Q-0068 DUE 041499 POC Shauna Martinez, (916)557-5110 or
FAX (916)557-5278 (Site Code DACA05) WEB:
http://www.spk.usace.army.mil/cespk-ct,
http://www.spk.usace.army.mil/cespk-ct. E-MAIL:
smartinez.spk.usace.army.mil, smartinez.spk.usace.army.mil. Potential
Sources Sought to Provide/Install Disinfectant System for Safe
Drinking Water.The purpose of this announcement is to locate potential
sources for replacement of two one-ton gas chlorination systems with
two 140 pound-per-day, on-site sodium hypochlorite generation systems
at Beale Air Force Base, California. The contractor will be required to
furnish all labor, plant, material, and equipment necessary to perform
the work. The automated, on-site sodium hypochlorite generation
systems provided and installed must utilize salt, water, and energy as
its raw materials in order to generate 0.8% sodium hypochlorite
(8200ppm plus or minus 200ppm). The contractor must reestablish full
water supply system and waste water treatment operations within eight
hours of water system shut-down following current potable water
practices. The contractor must be able to provide a factory trained and
certified technician with 24 hours of any service request with a
minimum field service capacity as follows: telephone support, 24 hours
per day toll free message center with a response time of 60 minutes;
on-site support, 365 days per year with 24-hour notice with a response
time of 24-hours; parts support 365 day per year with a response time
of 24-hours (overnight delivery). Contractor must provide
manufacturer's specifications, manuals, and single line as-built
drawings and parts and labor warranty at the end of installation.
Interested sources must demonstrate that they have: knowledge of
automated on-site sodium hypochlorite generation systems; have
designed, manufactured and installed automated on-site systems of equal
or greater generating capacity requirement, and must have a proven
automated system which generates 0.8% sodium hypochlorite (8200pppm
plus or minus 200ppm). This notice is not a request for competitive
proposals. See Note 22. Contact Shauna Martinez, Contract Specialist,
phone (916) 557-5110, fax (916) 557-5278, or email Posted 03/23/99
(A-SN311649). (0082) Loren Data Corp. http://www.ld.com (SYN# 0275 19990325\46-0003.SOL)