Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF MARCH 29,1999 PSA#2312

FM NAVICP Philadelphia PA, 700 Robbins Avenue Philadelphia, Pa 19111-5098

58 -- INTERRAGATOR-TRANSP SOL N0038398YT081 DUE 042399 POC Point of Contact -- Contact Point, Thomas F Kendra, 0233.14, (215)697-1383, Fax, (215)697-3161, Twx, Not-avail NSN 7R-5895-01-411-9604-EE, Ref Nr 165100-0003, Qty 1 EA, Delivery FOB Origin -- The subject item requires Government source approval prior to contract award, as the item is flight critical and/or the technical data available has not been determined adequate to support acquisition via full and open competition. Only the source(s) previously approved by the government for this item have been solicited. The time required for approval of a new source is normally such that award cannot be delayed pending approval of a new source. If you are not an approved source you must submit, together with your proposal, the information detailed in the http://www.navicp.navy.mil/prodserv/source/source.htm U.S. Navy Aviation Supply Office Source Approval Information Brochure. This brochure identifies technical data required to be submitted based on your company's experience in production of the same or similiar item, or if this is an item you have never made. This brochure can be obtained by calling NAVICP-P at (215) 697- 4243. If your request for source approval is currently being evaluated at NAVICP-P, submit with your offer a copy of the cover letter which forwarded your request for source approval. Offers received which fail to provide all data required by the Source Approval Brochure or document previous submission of all data required by the Source Approval Brochure will not be considered for award under this solicitation. Please note, if evaluation of a source approval request submitted hereunder cannot be processed in time and/ or approval requirements preclude the ability to obtain subject items in time to meet government requirements, award of the subject requirement may continue based on Fleet support needs. The NAVICP Commercial Item Identification Brochure and information regarding the Submission of Market Research Data is now available at: http://www.navicp.navy.mil/07/home073.htm http://www.navicp.navy.mil/07/home073.htm Drawings are not available. This requirement is to add various items for repair supporting the E2C IFF and APM-424 systems to a current long term repair contract with Litton Guidance & Control Systems. Litton is currently the only qualified commercial repair source for these items. Any other interested sources would require technical qualification to demonstrate repair capabilities. Interested sources should contact NAVICP Source Development at 215-697-1236 regarding technical qualification for future procurements. For synopsis purposes the following NSN's and quantities represent approx 98% of the items for repair under this requirement: 014115143 3 ea., 014115147 2 ea., 014118229 2 ea., 014118244 3 ea., 014119604 1 ea., 014119605 2 ea., 012422169 169 ea., 012413776 30 ea., 014118245 3 ea., 014121843 2 ea., 014124818 2 ea., 014127636 3 ea., 014130183 1 ea. . In addition, requisitions N00383-99-Y-7038 and N00383-99-Y-7040 apply for these requirements., See Note 22 (ACAVI0325049-346) Posted 03/25/99 (I-SN312903). (0084)

Loren Data Corp. http://www.ld.com (SYN# 0256 19990329\58-0010.SOL)


58 - Communication, Detection and Coherent Radiation Equipment Index Page