COMMERCE BUSINESS DAILY ISSUE OF APRIL 2,1999 PSA#2316Directorate of Contracting, Attn: ATZL-GCC, 600 Thomas Ave., Bldg 198,
Ft. Leavenworth, KS 66027-1389 Z -- DESIGN/BUILD FOR MISCELLANEOUS FIRE ALARM SYSTEMS SOL
DABT19-99-R-0001 POC DEBORAH K. SMITH,,Contract Specialist (913)
684-1630 or ELIZABETH M. BORNMAN, Contracting Officer, (913) 684-1626
The work and services to be performed consists of all architectural,
engineering, construction and other related services necessary to
provide: Design/Build Projects: Replace Fire Alarm System, Bldg 695,
Hoge Hall; Upgrade and Repair Fire Alarm System, Bldg 475, USDB Castle;
Install Fire Alarm System, Bldg 27, Post Theater; Install Fire Alarm
System, Bldg 302 Gruber Gym. Building transmitters furnished shall be
fully compatible and interchangeable with the existing Radio Fire Alarm
Monitoring Base Station, which is a Monaco D-700E. The work includes
the following: Bldg 695 is a 289,267 SF building complex consisting of
eleven interconnecting 3-story structures. It includes living space
for 616 occupants in two-man units, laundry facilities, janitorial
facilities, a nightclub, gymnasium facilities and an office cluster for
its operation. It is built of pre-cast floor slab construction with
gypsum board over metal lath interior walls, brick veneer on the
exterior walls and wood attic and roof sheathing. An addressable fire
alarm system is required for this building. Bldg 475 is a 365,606 SF
building complex consisting of eight, six-story wings radiating out
from a center octagon hub or rotunda, which is used for control
operations. This structure is the main internment building in a
maximum-security military prison, built between 1913 and 1921 and is
part of the Fort Leavenworth landmark historic district. It includes
living space for 1300 inmates, dining, gymnasium, administrative,
library, chapel etc. It is built of reinforced concrete and brick
construction. An addressable fire alarm system with zoned alarm
features is required for this building. Building 27 is a 10,150 SF
Theater facility with a concession area and seating capacity of 878
patrons. The building was erected in 1938 and is part of the Fort
Leavenworth landmark historic district. It is of brick construction. A
hardwired fire alarm system is required for this building. Building
302 is a 42,137 SF gymnasium with basketball, handball, and racquetball
courts, equipment storage and administrative facilities. The building
was erected in 1908 and is part of the Fort Leavenworth landmark
historic district. It is built of brick and steel construction. A
hardwired fire alarm system is required for this building. The
estimated completion for the projects (including both design and build)
is (1) Bldg 695 -- 225 calendar days, (2) Bldg 475 -- 195 calendar
days, (3) Bldg 27 -- 150 calendar days, and (4) Bldg 302 -- 150
calendar days. All hardware, firmware, software and information
technology systems separately or in combination with each other or
other elements specified in the documents developed under this contract
shall be Y2K compliant in accordance with FAR 39.106. The contract type
will be Firm Fixed-Price Indefinite-Delivery Requirements. Work shall
be issued by negotiated firm fixed-price task orders as required. Only
companies capable of design/build work should respond. The
solicitation for the acquisition of these design/build projectsis
formatted as a Request for Proposals in accordance with FAR Part 15 for
negotiated procurements using Two-Phase Design/Build Selection
Procedures in accordance with FAR 36.3. This proposal is advertised as
unrestricted. If a large business is selected for award, it must
comply with FAR 52.219-9 regarding the requirement for a
sub-contracting plan on the work it intends to subcontract. The
standard industrial code is 1731. The related small business size
standard is $7,000,000.00. The magnitude of this work is between
$500,000.00 and $1,000,000.00. The Government will award a contract
resulting from this solicitation to the responsible offeror whose
proposal conforms to this solicitation that will be the "Best Value" to
the Government, price and technical factors considered. This
procurement will consist of Two-Phases. Phase One is a pre-qualifying
process to determine which offerors will proceed to Phase Two. The
highest rated offerors will be selected and requested to submit Phase
Two proposals. The maximum number shall not exceed five unless the
contracting officer determines that a greater number than five is in
the Government's interest. The Government will amend the solicitation
to request Phase Two Technical and Price proposals from only the
selected offerors. Phase One offerors will be evaluated using the
following factors: (1) Past Performance; (2) Technical and Professional
Qualifications; and (3) Management Approach. All include sub-factors of
(1) Design team and (2) Construction teams. Firms must be capable of
performing design and construction services related to the design and
construction of fire-alarm system, upgrade replacement and/or
installation of addressable, addressable with zoned alarm features or
hardwired fire alarm systems in various types of buildings. Phase Two
is to determine "Best value" to the Government. Offers will be
evaluated on the following factors: (1) Best Technical Solutions and
(2) Price Proposal. The Government reserves the right to reject any or
all offers at any timeprior to award; to negotiate with any or all
offerors; to award the contract to other that the offeror submitting
the lowest price; and to award the offeror submitting the proposal
determined by the Government to be the most advantageous to the
Government. Offerors are advised that an award might be made without
discussion or any contact concerning the proposals submitted. Offers
should be submitted in the most favorable terms. Offerors should not
assume that they would be contacted or afforded an opportunity to
qualify, discuss, and/or revise their proposals. Firms submitting price
and technical proposals will not be compensated for submitted
specification or documentation. All work must be performed by or under
the direct supervision of licensed professional Engineers or
Architects. Firms desiring consideration must be capable of producing
all design drawings on Auto-Cad version 12.0 or higher, or a compatible
software system. Disclosure of sources selected to proceed to Phase Two
is prohibited in accordance with FAR 3.104. The receipt date for Phase
Two proposals will be established by amendment. Firms must show
adequate team capacity to design/build all four projects concurrently
meeting all schedules. All requests for the solicitation and any
inquiries must be submitted in writing. This is not a request for
proposals. Interested offerors may request and obtain the Phase One
solicitation of the two-phase process. The Phase One proposal due date
will be identified in the Phase One solicitation. The Phase One
solicitation will provide the scope of work, evaluation factors, and
submission information for interested offerors to prepare their Phase
One qualification proposals. No facsimile or telephone requests will be
accepted. Requests for the solicitation shall include the following
information: Name, Address, Telephone number, FAX number, Cage Code,
CCR and TaxPayer Identification Numbers and business size. Requests for
the solicitation shall be addressed to the following. Attention Deborah
K. Smith, Directorate of Contracting, 600 Thomas Unit 3, Fort
Leavenworth, Kansas 66027-1399. Telephone (913) 684-1630. Posted
03/31/99 (W-SN315056). (0090) Loren Data Corp. http://www.ld.com (SYN# 0255 19990402\Z-0003.SOL)
Z - Maintenance, Repair or Alteration of Real Property Index Page
|
|