COMMERCE BUSINESS DAILY ISSUE OF APRIL 8,1999 PSA#2320Department of the Army, Baltimore District, Corps of Engineer, 10 South
Howard Street, Room 7000, Baltimore, MD 21201-1715 C -- TWO INDEFINITE DELIVERY-TYPE (ENVIRONMENTAL LEAD) CONTRACTS, FT.
GEORGE G. MEADE, MD, BUT MAY BE USED THROUGHOUT THE BALTIMORE DISTRICT
SOL DACA31-99-R-0046 DUE 050899 POC Mary A. Riche (410) 962-4880,
William C. Ryals, Contracting Officer, (410) 962-3495 1. CONTRACT
INFORMATION: A-E services are required at Ft. George G. Meade, MD but
may be used throughout the Baltimore District. Contracts will be for a
base period not to exceed one year and two option periods. The amount
of work in each contract period will not exceed $1,000,000.00. An
option period may be exercised when the contract amounts for the base
period or preceding option period has been exhausted or nearly
exhausted. Contracts will be firm fixed price. The announcement is open
to all businesses regardless of size. The anticipated award is May
1999. SUBCONTRACTING PLAN REQUIREMENTS: If the selected firm is a large
business concern, a subcontracting plan with the final fee proposal
will be required, consistent with Section 806(b) of PL 100-180, PL
95-507, and PL 99-661. A minimum of 60% of the total planned
subcontracting dollars shall be placed with small business concerns. At
least 15% of the total planned subcontracting dollars shall be placed
with small disadvantaged businesses (SDB), including Historically Black
Colleges and Universities or Minority Institutions, and 8% with Women
Owned Small Businesses (WOSB). The plan is not required with this
submittal. 2. PROJECT INFORMATION: Work may consist of reports,
studies, testing, sample analysis, design criteria, management plans
for lead and asbestos contaminated materials, design and other general
multidiscipline architect engineering services for environmental
alterations, renovation, maintenance and repair, and minor construction
projects. 3. SELECTION CRITERIA: See Note 24 for general A-E selection
process. Firms shall have the capability to provide environmental,
certified industrial hygienist, civil, structural, mechanical and
electrical engineering; HVAC, plumbing, fire protection, geotechnical
and sanitary engineering; topographic surveying and cost estimates.
Concentration of work shall be in environmental engineering; sampling
testing, industrial hygienist services and preparation of management
plans for various facilities at Ft. Meade and response to regulatory
program requirements under CAA, CWA, CERCLA/SARA, RCRA/HSWA, NEPA, OSHA
and similar State statutes. Sampling and analysis, preparation of
written documentation permit support closures, etc. Work may also
include preparing studies and design for storm water management,
wetlands hydrology, sediment and erosion control, and National
Pollutant Discharge Elimination System (NPDES) permitting (including
obtaining all necessary state permits, etc.). Firms must demonstrate
the capability to conduct appropriate characterization, assessment and
remedial planning and design to identify and formulate corrective
measures for environmental projects. Firm must demonstrate the
capability to respond to multiple task orders concurrently. The
products (deliverables) are required to be performed using CADD
automation programs. The A-E shall be required to provide any
digitizing and/or translation services necessary to deliver the final
design product(s) in AutoCAD Rel. 14 on 3 inch HD diskettes formatted
for 1.44 MB. Specifications will be prepared using SPECINTACT. Cost
estimates will be prepared using the Microcomputer Aided Cost
Estimating System (MCACES). 4. SUBMISSION REQUIREMENTS: See Note 24 for
general submission requirements. Interested firms having the
capabilities to perform this work must submit one copy of SF 255. A SF
255 must be submitted for prime and joint ventures and a SF 254 must
be submitted for prime, joint ventures, and consultants, to the above
address, not later than the close of business on the 30th day after the
date of this announcement, If the 30th day is a Saturday, Sunday, or
Federal holiday, the deadline is the close of business the next
business day. Include the firm's ACASS number on the SF 255, Block 3b.
For ACASS information, call (503) 808-4591. The SF 255 and SF 254
shall clearly indicate the staffing of the office indicated to do the
work. Street address: City Crescent Building, ATTN: Mary A. Riche, Rm
7000, 10 South Howard Street, Baltimore, MD 21201. Contracting
questions can be directed to mary.a.riche@nab02.usace.army.mil.
Technical questions should be directed to Ms. Faith McNamee, (301)
677-9354. "In order to comply with the Debt Collection Improvement Act
of 1996, all contractors must be registered in the Central Contractor
Registration (CCR) to be considered for an award of a Federal
contract. For information regarding registration, contact: (1) CCR Web
site at http://www.acq.osd.mil/ec.; (2) Dial up modem at (614)
692-6788 (User ID: ccrpub; Password: pub2ccri); (3) through any DoD
Certified Value Added Network. To review the database the web site is
http://www.fedecnavigator.disa.mil. Additionally, a paper form for
registration may be obtained from the DoD Electronic Commerce
Information Center at 1-800-334-3414." Solicitation packages are not
provided for this project. This is not a request for proposal.*****
Posted 04/06/99 (W-SN316668). (0096) Loren Data Corp. http://www.ld.com (SYN# 0040 19990408\C-0004.SOL)
C - Architect and Engineering Services - Construction Index Page
|
|