COMMERCE BUSINESS DAILY ISSUE OF APRIL 16,1999 PSA#2326Bureau of Reclamation, Snake River Area Office, 214 Broadway Avenue,
Boise, ID 83702 38 -- PETROLEUM DISTRIBUTION EQUIPMENT SOL 1425-99-SQ-11-00030 DUE
042999 POC Karl Ames -- Civil Engineer 208-334-1870/Marie Day -- Purch.
Agent -- 208-334-1744 WEB: MDAY@PN.USBR.GOV, MDAY@PN.USBR.GOV. E-MAIL:
MDAY@PN.USBR.GOV, MDAY@PN.USBR.GOV. This is a combined
synopsis/solicitation for commercial items prepared in accordance with
the format FAR Subpart 12.6 as supplemented with additional
information included in this notice. This announcement constitutes the
only solicitation;proposals are being requested and a written
solicitation will not be issued. Solicitation 1425-99-SQ-11-00030 is
issued as a Request for Quotations (RFQ) and incorporates provisions
and clauses in effect through Federal Acquisition Circular 97-08. This
acquisition is a total small business set-aside. The size standard is
100 employees, the standard industrial classification code is 3586,
and the NAICS code is 333913. MARINE SERVICE STATION OWYHEE RESORT
SPECIFICATIONS 1. GENERAL -- The Bureau of Reclamation, Snake River
Area Office has a requirement for a marine service station at Owyhee
Resort at Owyhee Reservoir, Oregon, including the following items: A.
Furnish and install an above ground vaulted fuel storage tank -- 2000
gallon capacity, with the accessories as follows: a. Vent pipe and cap,
steel pipe, 2-inch diameter by 8-feet long, b. Emergency vent,
c.Overfill prevention valve, d. Tank gauge, e. Calibrated gauge stick
to determine tank volume, f.Tank labeling B. Furnish and install a fuel
dispensing system, including: a. Submersible turbine pump, 1/3HP, 115
volts AC, 60 HZ, single phase, b. Dispenser unit, c. Nozzles (2) --
fully automatic shutoff, d. Hose end swivels (2) -- -inch e. Breakaway
connector valves (2) -- -inch, with 9" whip hose, f. Pump hose --
-inch x 12-feet, g. Pump hose -- -inch x 50-feet, h. Hose reel, with
rewind motor, i. Pump fuel identification decals, etc., j. Equipment
platform, with spill containment C. Furnish and install electrical
service, including: a. Service panel,100 amps, b. Buried conduit,
approximately 300 feet, c. Emergency-stop switch D. Delivery and
off-loading of the storage tank, dispensing system, and accessories to
the Owyhee Resort, Oregon 2. ABOVE GROUND FUEL STORAGE TANK -- The
tank shall havean Underwriter Laboratories UL-142 and UL-2085 listing
for protected secondary containment for above ground tanks containing
flammable or combustible liquids. The tanks shall be constructed of an
inner, -inch thick minimum, steel tank and enclosed within a 6-inch
minimum thickness reinforced concrete outer vault; or enclosed within
an -inch thick minimum outer steel tank, with 6-inches of insulating
concrete surrounding the inner tank. The tank shall have at least a
2-hour fire protection rating. The tank exterior shall have a
protective epoxy coating. The tank shall meet the minimum requirements
set forth in the NFPA 30, Flammable and Combustible Liquids Code.
Tanks shall be marked with "FLAMMABLE", "NO SMOKING", product
identification, and other signs as required by state and local codes.
The tank shall be provided with the required venting and product
dispensing and filling ports. A port shall be provided to allow the
physical monitoring of the annular space between the inner steel tank
and the secondary containment. The tank shall be covered under a
20-year minimum limited warranty. Venting meeting the applicable codes
shall be provided and installed, including a 2-inch diameter by 8-feet
long vent steel pipe and cap and an emergency vent meeting the
requirements of the applicable codes. Overfill prevention shall be
provided and installed, including a valve located within the fill pipe
to close automatically at a specified level. The overfill prevention
valve, with a cylindrical float, shall be an OPW Model 61 fSTOP-1000,
or equivalent. A direct reading level gauge at the tank visible from
the fill location shall also be provided and installed. The tank gauge
shall be a clock gauge style. A calibrated gauge stick shall be
provided as a back up method to determine tank volume. The tank shall
be provided with 4-inch full length skids. As an alternative to a skid
mounted tank, a precast reinforced concrete slab can be provided and
installed. The precast reinforced concrete slab shall be of a size and
thickness to fully support the filled weight of the tank. The concrete
slab shall be at least 6-inches longer and wider than the tank
dimensions. Provide a minimum six-inch thick granular subgrade,
compacted, and graded to a level uniform subsurface prior to the cast
slab placement. 3. FUEL DISPENSING SYSTEM -- A fuel dispensing system
shall be provided and installed. The system shall include a dispenser,
similar to a Bennett Fleetmaster Model 4012, or equivalent. The
dispenser shall have a four-digit register display (999.9 gallons), a
seven-digit register totalizer (999,999.9 gallons), and a five-digit
register display ($999.99 maximum), with an automatic register reset.
The dispenser shall have prepay capability and provided with a pulser
kit 100:1. An UL-Listed submersible turbine pump, HP, 115 volts AC, 60
HZ, single phase shall be provided and installed. The pump shall be a
FE Petro Model No. SPT 33, or equivalent, with a control box. Two
UL-Listed nozzles, with fully automatic shutoff and hold open rack and
trigger shall be provided and installed. The nozzles shall be OPW
Model 11AP-0400, or equivalent. The nozzles shall be provided with
-inch hose end swivels, OPW Product No. 241TPS-0241, or equivalent.
UL-Listed fuel dispensing hoses, one -inch x 12-feet and another -inch
x 50-feet shall be provided and installed. Breakaway connector valves
-inch, with 9" whip hose shall be provided and installed. The
breakaway connectors shall be OPW Product No. 66-0075, or equivalent.
The dispenser shall be provided with all pump fuel identification
decals, etc. as required by applicable codes. A hose reel, with an
explosion proof rewind motor, shall be provided and installed, with the
necessary plumbing from the dispenser. The hose reel shall be a Duro
Reel Model No. 3205, with an explosion proof 115 V, HP motor, or
equivalent. The dispenser shall be installed on a 6-foot by 6-foot
equipment platform, with spill containment capability. An enclosure,
with a lockable roll-up door for security, shall be provided and
installed to enclose the dispenser and hose reel. Collision protection
shall be provided, as necessary to comply with applicable codes. Pipe
bollards or precast concrete barriers may be used to provide collision
protection. 4. ELECTRICAL -- Electrical equipment shall be provided and
installed as necessary to service the marine service station. The
electrical service shall be installed in accordance with the
requirements of the National Electrical Code (NEC), NFPA, and local
code requirements. Provide and install a 100-amp service panel on an
existing pole. Provide and install up to 300 feet of buried electrical
conduit. Depending on the site selected for the marine service
station, the buried conduit may cross a paved access road. The asphalt
repair, if required, will be done by others. All electrical devices
used with or located within 20 feet of the marine service station
should conform to NFPA 70, Hazardous Locations. All electrical conduits
and wiring at the marine service station shall be explosion proof and
instrict accordance with NEC Class-1, Division 1 or other local
standards, whichever is more strict. An emergency shut-off switch is
required to be mounted in a location visible from the dispenser. The
switch shall be located on a post and at a distance which meets the
applicable code requirements. A sign or label shall be provided and
installed identifying the switch as an emergency shut-off switch.
Provide and install the necessary electrical grounding required for the
tank and dispensing system. 5. DELIVERY AND INSTALLATION -- The tank,
fuel dispensing system, and all other equipment required for the marine
service station shall be delivered and off loaded to the Owyhee Resort
is located at Owyhee Reservoir, approximately 35 miles southwest of
Nyssa, Oregon and about three miles south of Owyhee Dam. The tank, fuel
dispensing system, and all other equipment shall be installed at the
site designated by an authorized representative of the bor in
accordance with these specifications and any applicable codes.The
completed fully functional marine service station will be inspected and
tested by a representative of the Bureau of Reclamation for acceptance.
Required delivery date will be on or before 5/21/99. The following FAR
provisions and clauses apply to this acquisition: 52.212-1
Instructions to Offerors -- Commercial Items (OCT 95), 52.212-2
Evaluation -- Commercial Items (OCT95), 52.212-3 Offeror
Representations and Certifications -- Commercial Items (JAN97),
52.212-4 Contract Terms and Conditions -- Commercial Items (MAY 97),
52.212-5 Contract Terms and Conditions Required to Implement Statutes
or Executive Orders -- Commercial Items (AUG 96). Clause 52.212-5,
paragraph (b) is tailored to incorporate the following clauses by
reference: 52.219-8, 52.219-14, 52.222-26, 52.222-35, 52.222-36,
52.222-37, 52.225-3, 52.225-18, and 52.225-21 with Alternate 1.
Offerors are to include a completed copy of the provision at 52.212-3,
Offer Representations and Certifications -- Commercial Items (JAN
97)with the RFQ. Offerors may request a copy of this clause be faxed to
them. The closing time and date for receipt of proposals is Close of
Business April 29, 1999. All sources responding to this
synopsis/solicitation shall do so in writing. All sources shall submit
information relating to business status, including identification as
to whether small, large, minority owned, and/or woman owned. All
responsible sources may submit an offer, which will be considered by
this agency. Fax requests will be accepted at the following number
Attn: Marie Day: 208-334-9562, and e-mail requests through the
following address: mday@pn.usbr.gov. See Note 1. Posted 04/14/99
(W-SN320282). (0104) Loren Data Corp. http://www.ld.com (SYN# 0234 19990416\38-0003.SOL)