COMMERCE BUSINESS DAILY ISSUE OF APRIL 19,1999 PSA#2327Bechtel National, Inc., P.O. Box 193965 -- 45/08/C33, San Francisco, CA
94119-3695 39 -- AGITATOR & STATIC MIXER FABRICATION/TESTING SOL 24115 DUE 042999
POC Valerie Williams (713) 561-8486 E-MAIL: click here to contact via
e-mail now, vlwillia@bechtel.com. This is a Solicitation for Sources
capable of design, fabrication and testing of Titanium agitators for
installation & use at the Aberdeen Chemical Agent Disposal Facility in
Edgewood, MD. DESIGN AND FABRICATION REQUIREMENTS: Ability to design
and fabricate Titanium agitators for 8' high by 6'6" diameter reactor
vessels and Titanium static mixers that create an average 100 micron
droplet size in a 150 GPM recirculation loop for the reactor vessel.
The manufacturer will be provided with relevant physical and chemical
properties of the materials to be mixed and the proposed mixing
conditions. The designer should be able to demonstrate the ability to
create the required 100 micron (or smaller) droplet size at full scale,
prior to fabrication of the Titanium units. TESTING: Ability to test a
full-scale reactor (8 ft. high by 6'6" diameter)/agitator combination
with a recirculation loop (150 Gallons per Minute) that contains a
static mixer. The tester should have the ability to determine the
average droplet sizes within the reactor, and at the inlet and outlet
of the static mixer. The test will employ a simulant to the chemicals
identified in the Design and Fabrication requirements, and will be used
to verify the theoretical agitator and static mixer designs prior to
fabrication. SCOPE OF SUPPLY: Full scale, or near full scale, system
testing. Six (6) Titanium static mixers -- designed for a flowrate of
150 GPM. Six (6) Titanium agitators -- designed for 8' x 6'6" diameter
reactor vessel. If you have proven capability to provide these
products and services, submit details of your qualifications to Valerie
Williams, Bechtel National, Inc., via FACSIMILE (713) 572-3119, E-MAIL,
vlwillia@bechtel.com, or MAILING ADDRESS, 3050 Post Oak Blvd. Suite
1500, Houston, TX 77056. Indicate if your firm qualifies as small,
small-disadvantaged or woman-owned as detailed in FAR 52.219-1 through
52.219-3. Posted 04/15/99 (W-SN320570). (0105) Loren Data Corp. http://www.ld.com (SYN# 0223 19990419\39-0001.SOL)
39 - Materials Handling Equipment Index Page
|
|