COMMERCE BUSINESS DAILY ISSUE OF APRIL 19,1999 PSA#2327Bechtel National, Inc., P.O. Box 193965 -- 45/08/C33, San Francisco, CA
94119-3695 44 -- AAGITATOR & STATIC MIXER FABRICATION/TESTING SOL 24115 DUE
042999 POC Valerie Williams (713) 561-8486 E-MAIL: click here to
contact via e-mail now., vlwillia@bechtel.com. This is a Solicitation
for Sources capable of design, fabrication and testing of Titanium
agitators for installation & use at the Aberdeen Chemical Agent
Disposal Facility in Edgewood MD. DESIGN AND FABRICATION REQUIREMENTS:
Ability to design and fabricate Titanium agitators for 8' high by 6'6"
diameter reactor vessels and Titanium static mixers that create an
average 100 micron droplet size in a 150 gmp recirculation loop for the
reactor vessel. The manufacturer will be provided with relevant
physical and chemical properties of the materials to be mixed and the
proposed mixing conditions. The designer should be able to demonstrate
the ability to create the required 100 micron (or smaller) droplet
size at full scale, prior to fabrication of the Titanium units.
TESTING: Ability to test a full-scale reactor (8 ft. high x 6' -- 6"
diameter)/agitator combination with a recirculation loop (150 gallons
per minute) that contains a static mixer. The tester should have the
ability to determine the average droplet sizes within the reactor, and
at the inlet and outlet of the static mixer. The test will employ a
simulant to the chemicals identified in the Design and Fabrication
requirements, and will be used to verify the theoretical agitator and
static mixer designs prior to fabrication. SCOPE OF SUPPLY: Full scale,
or near full scale, system testing. Six (6) Titanium static mixers --
designed for a flowrate of 150 gpm. Six (6) Titanium agitators --
designed for 8' x 6' -- 6" diameter reactor vessel. If you have proven
capability to provide these products and services, submit details of
your qualifications to Valerie Williams, Bechtel National, Inc. via
FACSIMILE (713) 572-3119 or E-MAIL, vlwillia@bechtel.com, or MAILING
ADDRESS, 3050 Post Oak Blvd. Suite 1500, Houston, TX 77056. WRITTEN
REPLIES ONLY PLEASE. Indicate if your firm qualifies as small,
small-disadvantaged, or woman-owned as detailed in FAR 52.219-1 through
52.219-3. Posted 04/15/99 (W-SN320538). (0105) Loren Data Corp. http://www.ld.com (SYN# 0238 19990419\44-0002.SOL)
44 - Furnace, Steam Plant, Drying Equipment and Nuclear Reactors Index Page
|
|