COMMERCE BUSINESS DAILY ISSUE OF APRIL 26,1999 PSA#2332United States Air Force, Air Force Reserve Command, 452 LSS/LGC, 820
Baucom Ave, NW, Suite 101, March ARB, CA, 92518-2260 61 -- DIESEL ENGINE DRIVEN GENERATOR SOL F0460599Q0204 DUE 052699 POC
Sissy Widman, Purchasing Agent, Phone 909-655-5386, Fax 909-655-3772,
Email Sissy.Widman@riv.afrc.af.mil -- Mary Boswell, Contracting
Officer, Phone 909-655-3116, Fax 909-655-3772, Email WEB: Visit this
URL for the latest information about this,
http://www.eps.gov/cgi-bin/WebObjects/EPS?ACode=P&ProjID=F0460599Q0204
&LocID=521. E-MAIL: Sissy Widman, Sissy.Widman@riv.afrc.af.mil. March
Air Reserve (ARB) Base requires purchase and delivery via FOB
destination to installation (government will offload) a Generac Model
#1200TA, 200 KW diesel engine driven generator, (equal or greater
value) substituting an electronic governor for the listed mechanical
governor consisting with the following type codes and accessories:
SD200-K36133D18CPYYY, 13.3L turbo charged diesel fueled engine, 200 KW
alternator, 12 lead reconnectable wired for 277/480V, three phase, 60
HZ frequency with PMG exciter, 1% voltage regulation, _C_ option
control panel with: AC meter package, phase selector switch, cyclic
cranking with crank limiter, voltage adjust rheostat, hourmeter, oil
pressure and coolant temperature gauges, DV battery charge ammeter,
panel light, lamp test/reset switch-auto/off/manual switch with red
_Not in Auto_ annunciator light, latched shutdowns, five light
annuciators for: low oil pressure, high coolant temperature, overcrank,
overspeed & RPM sensor loss, mechanical governor with a 5.0% frequency
regulation, 350 Amp main line circuit breaker, fuel shut-off solenoid
valve, fuel filter and water separator, engine coolant heater, battery
charging alternator, battery cables, solenoid activated starter motor,
air cleaner and oil filter with internal bypass, oil and antifreeze,
oil and radiator drain extensions, vibration isolators between
engine/alternator and base frame, cool flow radiator with fan guards,
outdoor weather protective enclosures, installed critical muffler,
emergency stop button, air duct adapter, 2ea -- 135AH 12vdc batteries
(Type 4D), standard flex exhaust, 2 Amp 24vdc battery charger, 3/8_
diesel flex fuel lines (2 required), 3_x 18_ vibration pads, 720 gallon
fuel tank to include stub up, double wall, UL approved, 36 inches in
height and _( 1 ) set of Owner_s manuals. One automatic transfer switch
consisting of the following typecode and accessories: GTS040N-3K2LSNA
_ 3 pole, 400 amp transfer switch rated at 600 volts, time delay
neutral with in phase monitor, safety disconnect switch, system voltage
277/480 VAC three phase,, two wire start system, adjustable logic
control, standard exerciser, NEMA 1 enclosure, utility voltages sensing
controls to include: drop-out and pick-up (70 to 95% adjustable), and
utility interrupt delay (1 to 10 seconds adjustable), Standard 12 month
warranty, UL 1008 listed, and ( 1 ) set of owner_s manual. This
announcement constitutes the only solicitation: proposals are being
requested and written solicitation will not be issued. All contractors
effective 1 June 1998, are required to be registered in the Central
Contractor Registration (CCR). Please submit your quotes in writing to
FAX number (909)655-3772. EMAILADD: Sissy.Widman@riv.afrc.af.mil
EMAILDESC: <A
HREF="mailto:Sissy.Widman@riv.afrc.af.mil">mboswell@riv.afres.af.mi
l</A> Posted 04/22/99 (D-SN323295). (0112) Loren Data Corp. http://www.ld.com (SYN# 0281 19990426\61-0004.SOL)
61 - Electric Wire and Power and Distribution Equipment Index Page
|
|