COMMERCE BUSINESS DAILY ISSUE OF MAY 4,1999 PSA#2338CH2M Hill, Inc., 613 NW Loop 410, Suite 200, San Antonio, TX 78216 M -- PRIVATIZATION OF UTILITY SYSTEMS AT W.K. KELLOGG AIRPORT, AIR
GUARD STATION, BATTLE CREEK, MICHIGAN DUE 061599 POC For the U.S. Air
Force: CH2M HILL, 613, NW Loop 410, Suite 200, San Antonio, TX 78216
POC: Laura Hein(lhein@ch2m.com), Tel (210)377-3081 E-MAIL: Laura Hein,
lhein@ch2m.com. PRIVATIZATION UNDER 10 USC 2688, UTILITY SYSTEMS:
CONVEYANCE AUTHORITY AT W.K. KELLOGG AIRPORT, AIR GUARD STATION, BATTLE
CREEK, MICHIGAN, SOL: N/A, DUE: 061599 POTENTIAL SOURCES SOUGHT
PURPOSE: The Air Force seeks to identify responsible potential sources
and obtain information in regards to privatization of utility systems
in accordance with 10 USC 2688, "Utility Systems: Conveyance
Authority". The Commander of W.K. Kellogg Airport, Air Guard Station is
seeking interest and information specifically for the potential
privatization of the potable water, wastewater, and electrical utility
systems at W.K. Kellogg Airport, Air Guard Station, Battle Creek,
Michigan. OBJECTIVE: Should privatization result, the ownership of W.K.
Kellogg Airport, Air Guard Station potable water, wastewater, and
electrical utility systems, operation and maintenance and obligation to
continue to provide utility service for an indefinite and ongoing
period will transfer to a utility service provider. All responsibility
for maintaining reliable utility service, including such items as
environmental compliance, maintenance costs, major system renovations,
construction, equipment, manpower and overhead costs will become the
utility service provider's responsibility. It is intended that the
privatization will ultimately reduce the Air Force's life-cycle costs
for operating and maintaining utility systems and services. SYSTEM
DESCRIPTIONS: The following information provided is only an estimate
and is subject to change. Water -- Potable water is supplied to the
Kellogg AGS by the City of Battle Creek, MI. Water is distributed
throughout the base in approximately 13,000 lineal feet of cast iron,
ductile iron, and PVC water mains. Sizes range up to 12-inch. The water
system includes about 35 fire hydrants. Wastewater -- Wastewater
collected on the AGS is discharged to the City of Battle Creek sewer
system for treatment at their wastewater treatment plant. The
wastewater system includes about 14,000 lineal feet of vitrified clay,
cast iron, ductile iron, and PVC piping. Sizes range from 4-inch
through 8-inch. The collection system generally flows by gravity,
although there are 3 duplex lift stations. The wastewater system also
includes six oil/water separators ranging in size from 100 to 5000
gallons. Electrical -- Power for the W.K. Kellogg Air Guard Station
(AGS) is supplied by Consumers Energy. Power is supplied to the main
switch station at 24.9 kV. Power is supplied to several buildings at
24.9 kV and a main transformer provides 8.32 kV for distribution to the
rest of the AGS. The electrical distribution system includes
approximately 3,720 lineal feet of overhead primary distribution lines
and about 7,500 lineal feet of underground primary distribution lines.
The electrical system also includes approximately 24 pole-mounted
street lights and 18 pole-mounted area/ramp lights. PROCEDURES: This
request to interested parties is for gathering information and is a
required component of a systematic process to evaluate the interested
parties under the Air Force's utilities privatization program. In order
to minimize costs both to potentially interested parties and the
government, this notice is being issued to determine the interest and
feasibility of proceeding with a formal request for proposals. Should
insufficient credible interest be identified for a privatization
action, it is highly likely that no formal solicitation will be issued.
SHOULD INTEREST BE DETERMINED SUFFICIENT, A FORMAL REQUEST FOR
PROPOSALS MAY BE FORTHCOMING. Small Business interests shall note the
FAR Part 19 Standard Industrial Codes (SIC) and Size Standards for the
utility systems identified in this announcement. Some, all, or any
combination of the following may apply. SIC/SS: 4911/4Million (M)
Megawatt hours, 4922/$5M, 4923/$5M, 4924/500, 4925/$5M, 4931/$5M,
4932/$5M, 4939/$5M, 4941/$5M, 4952/$5M, 4953/$6M, 4959/$5M, 4961/$9M,
4971/$5M. REQUESTED RESPONSE: Interested parties should provide a
statement of interest on company letterhead (not to exceed 20 pages in
length). The statement should include as a minimum the following
criteria: (1) specific utility system(s) of interest and desired
bundling/grouping of utilities to purchase; (2) capability and
experience in ownership, operation and maintenance of similar utility
systems; (3) financial capacity to purchase, expand and operate the
utility systems; (4) statement detailing the understanding of the
obligation to serve in regards to continuous utility service; (5)
conceptual rate plan (excluding numerical analysis or proposed rates),
i.e. will charges for utility service be made from existing rates or
from rates developed specifically for service at the individual
base(s); (6) ideas regarding conjunctive metering and billing for
service on base (excluding numerical analysis or proposed rates); (7)
discussion of your conceptual basis (excluding numerical analysis or
proposed price) for a proposed purchase price (capitalized earnings
value, replacement cost new less depreciation, original cost less
depreciation, or other); (8) statement detailing your understanding of
applicable state and local utility laws and your compliance
capability; (9) statement detailing your understanding of any existing
franchises and your ability to provide service given these conditions;
(10) statement detailing your understanding of federal, territorial,
and local environmental laws and regulations and familiarity and
experience with environmental compliance procedures and regulations for
Michigan and the U. S. Environmental Protection Agency; and (11)
business size (large, small, small-disadvantaged; 8(a); women-owned).
Elaborate proposals or pricing information is neither required nor
desired. Under no circumstances will cost data for the existing systems
be provided. Any innovative and new conceptual ideas to achieve the
stated objective are encouraged. If a site visit and the provision of
additional data are later determined necessary, notification will be
provided by way of an amendment to this announcement. It should be
noted that the RFIsfor different Air Force Bases and utility systems
may be issued in the same time frame. A separate response to each RFI
is required. Please respond electronically as well as with hard copy.
The point of contact is Laura Hein(lhein@ch2m.com), Tel (210)377-3081.
Posted 04/30/99 (W-SN326381). (0120) Loren Data Corp. http://www.ld.com (SYN# 0065 19990504\M-0013.SOL)
M - Operation of Government-Owned Facilities Index Page
|
|