COMMERCE BUSINESS DAILY ISSUE OF MAY 7,1999 PSA#2341Defense Reutilization And Marketing Service, DRMS-TPO, 74 Washington
Avenue North, Battle Creek, MI 49017-3092 52 -- MULTIPLE DETECTOR MICROPROCESSOR AND SYSTEM INSTALLATION OF SAME
SOL SP4410-99-Q-2010 DUE 052099 POC POC Kathy Smalley (Contract
Specialist) 616-961-4073 or Virginia Mayhew (CO) 616-961-7130 WEB:
http://www.cbdnet.access.gpo.gov, http://www.cbdnet.access.gpo.gov.
E-MAIL: ksmalley@drms.dla.mil, ksmalley@drms.dla.mil or
vmayhew@drms.dla.mil. This is a combined synopsis/solicitation
SP4410-99-Q-2010 for Multiple Detector Microprocessor containing (1) 1
ea. Microprocessor based electronics, (2) 1 ea. Infrared motion
sensor, (3) 1 ea. 5 microCi 137Cs check source, (4) 1 ea. Alarm Strobe,
(5) 2 ea. 1440 in3 Plastic detectors. THIS ANNOUNCEMENT CONSTITUTES THE
ONLY SOLICITATION; PROPOSALS ARE BEING REQUESTED AND A WRITTEN
SOLICITATION WILL NOT BE ISSUED. The Defense Reutilization and
Marketing Service (DRMS) intend to enter into a firm-fixed price
contract. the solicitation document and incorporated provisions and
clauses are those in effect through Federal Acquisition Circular 97-02.
This announcement is published as a Total Small Business Set-Aside
action per FAR 52.219-1 and 52-219-6. You must be classified as a small
business and have the proper amount of employees to quote on this
requirement. All eligible, responsible sources may submit an offer.
Item description are as follows: Audio: Unimorph type speaker (greater
than 68 dB at 2 feet);Meter: 6" (15.2cm)arc 1 mA analog type; Meter
Dial: 0-25 kcps. The system will continuously monitor background levels
until the infrared sensor identifies an object. It will then
automatically switch to checking the object for radiation caused by
contamination until the object is clear of the sensor at which time the
system will return to monitoring background. ALARM RESET: Pushbutton to
reset the alarm; FAIL 1:; FAIL 2:; RS-232: 9 pin connector to allow for
connection of computer for data logging; CONTROLS: 5 pin connector
allowing for connection of infrared sensors; RELAYS: 3 pin connector
allowing for connection of external alarm indicators; POWER: 95-135 VAC
(178-240 VAC available on request), 50-60 Hz single phase (less than
100 mA); ELECTRONICS CONSTRUCTION: Steel NEMA 12 enclosure; TEMPERATURE
RANGE: 5 degree F(-15C)to 122 degree F(50C) May be certified to operate
from -40 degrees F (-40C) to 150 degree F (65C); SIZE: Electronics 15"
(38.1cm)H x 12"(30.5cm)W x 6.5"(16.5cm)D Detectors (ea.) 72" (183 cm)H
x 8"(20.3 cm) Diameter; WEIGHT: Electronics 18lbs (8.2kg); Detectors
(ea.) 65 lbs (29.5 kg). System Installation should also be included
which includes plans for detector stands, running of conduit cables,
final hookup and system. Ordered and placed as follows: 1 ea. Fort
Riley; 2 ea. San Diego; 2 ea. Fort Lewis; 1 ea. Anniston Army Depot; 2
ea. Letterkenny, PA; 1 ea. Texarkana; 1 ea. McClellan. FAR 52.212-1
Instructions to Offers-Commercial (APRIL 1998). FAR 52.213-3 Offeror
Representations and Certifications-Commercial Items (JAN 1997). A
completed copy of this provision must be submitted with the offeror's
proposal. FAR 52.212-4 Contract Terms and Conditions-Commercial Items
(APRIL 1998). FAR 52.212-5 Contract Terms and Conditions Required to
Implement Statutes or Executive Orders-Commercial items (APRIL 1998).
The following blocks are x'd: (b)(6-8)(11). Quotes must be received no
later than 3:00 P.M., EST., 5/20/99. People to contact for information
regarding the solicitation are Kathy Smalley (Contract Specialist) via
e-mail ksmalley@drms.dla.mil or Virginia Mayhew (Contracting Officer)
via e-mail vmayhew@drms.dla.mil or fax (616)961-4474. IMPORTANT
NOTICE: DFARS 252-204-7004 "Required Central Contractor Registration"
applies to all solicitations issued on/after 6/1/98. Lack of
registration in the CCR database will make an offeror/quoter INELIGIBLE
FOR AWARD. Please ensure compliance with this regulation when
submitting your quote. Call 1-888-227-2423 or visit the Internet at
http://ccr.dlsc.dla.mil. Parties responding to this solicitation may
submit their quote in accordance with their standard commercial
practices. The required delivery is fifteen (15) calendar days after
contract award. Posted 05/05/99 (W-SN328221). (0125) Loren Data Corp. http://www.ld.com (SYN# 0513 19990507\52-0001.SOL)