COMMERCE BUSINESS DAILY ISSUE OF MAY 11,1999 PSA#2343Contracting Officer (637/90C), VA Medical Center, 1100 Tunnel Road,
Asheville, NC 28805 C -- FIRE SPRINKLERS, BUILDING 47 SOL 637-36-99 DUE 060899 POC Dave
Thomsett 828-299-5830 Contractor shall provide A/E services to fully
fire sprinkle Building 47 located at the VA Medical Center, Asheville,
NC. Statement of Objectives: Fully fire sprinkle Building 47 to bring
it into full compliance with NFPA 101, NFPA 13, applicable North
Carolina State Codes, and VA Criteria. Conduct appropriate hydraulic
studies to determine adequacy of water supply and pressure. Coordinate
with and tie into the fire sprinkler system to be installed by the
recently awarded Ambulatory Care Addition Project, a $24 million
construction project. Evaluate the feasibility of upgrading the
existing fire alarm system to an addressable system. Utilize the VA
Fire Protection Design Manual dated March 1, 1996. The A/E shall retain
the services of a fire protection engineer for the project in
accordance with Qualifications and Scope of Services, Project Fire
Protection Engineer (dated March, 1996). Background: Building 47 is the
main building providing inpatient and outpatient services at the
medical center. Placedin service in 1968, the building is 321,366 GSF.
The basement level houses support services, the first floor houses
administrative, clinical, laboratory, and pharmacy functions. The
second through fifth floors house inpatient wards and various clinics.
There is a penthouse for building service equipment. The building is
presently 13% fire sprinkled. A contract was recently awarded to add
approximately 100,000 SF to the front of the building for outpatient
ambulatory care services. Part of this ambulatory care project will
renovate 80% of the first floor and will include new fire sprinklers.
The existing water services to Building 47 include: a. fire sprinkler
standpipe (4-inch supply), and b. fire hose standpipe (6-inch supply).
Note: the fire hose standpipe system has been tapped into to provide
sprinkler coverage for recent renovation projects. The existing fire
alarm system is manufactured by Simplex and consists of three 4100
master panels and twenty-eight 4002 sub panels, servicing 28 fire and
smoke zones. There is a smoke purge system controlled by Johnson
Controls Metasys. The estimated construction cost range is between
$1,000,000 and $2,000,000, and is subject to the availability of funds.
All interested parties should submit two copies of forms SF 254 & 255
to the above address. Firms should include all relevant information
regarding past projects designed which are similar in type to this
project. All responses are to be received by close of business 6/8/99.
Posted 05/07/99 (W-SN329012). (0127) Loren Data Corp. http://www.ld.com (SYN# 0017 19990511\C-0003.SOL)