COMMERCE BUSINESS DAILY ISSUE OF MAY 28,1999 PSA#2356United States Air Force, Direct Reporting Units, 10 ABW/LGC, 8110
Industrial Drive, Suite 200, USAF Academy, CO, 80840-2315 58 -- SALE AND INSTALLATION OF A CLOSED CIRCUIT VIDEO SURVEILLANCE SOL
Reference-Number-F0561199T1172 DUE 060399 POC Mike Slocum, Contract
Specialist, Phone (719)333-6572, Fax (719)333-4404, Email
slocumm.lg@usafa.af.mil -- Bruce Taylor, Contracting Officer, Phone
(719) 333-2869, Fax (719)333-4747, Email WEB: Visit this URL for the
latest information about this,
http://www.eps.gov/cgi-bin/WebObjects/EPS?ACode=P&ProjID=Reference-Num
ber-F0561199T1172&LocID=479. E-MAIL: Mike Slocum,
slocumm.lg@usafa.af.mil. This modification is in response to bidders
questions: Most areas where cameras are to be installed have 10 foot
high ceilings. High areas (basketball courts/25 feet, racquetball
courts/20 feet, swimming pool/25 feet, multipurpose room/25 feet. The
cameras would be located well below this maximum height. Some portions
of the building are 'single story' as noted above, the remainder of
the building is 'two story'. All camera locations will have conduit
running to those locations. This conduit will all run to Control
equipment room 117. This new and existing conduit will be empty. New
CCTV wiring will have to be installed. The MILCON project is installing
ONLY the conduit to the new Control Equipment room 117. Color cameras
proposed of a higher resolution and better overall video quality than
that specified will be considered a better value. Cabling, connectors,
wiring and other supplies as necessary will be supplied by the
contractor and a certain brand/manufacturer is no longer a arequirement
except asan equivalent of what is specified. Sale and Installation of
a Closed Circuit Video surveillance system in Building 5234, Community
Fitness and Sports center, US Air Force Academy. Installation would
begin no earlier than August 15, 1999 or no later than September 1,
1999. The contractor will provide the following equipment items or
their equivalent: DESCRIPTION MANUFACTURE/MODEL QUANTITY Camera
Sony/SCC-104 28 Lens Compstar/TGZ3514-FCS 28 Multiplexer Vicon/AUR99-DC
2 Monitor Sony/SSM-20N1U 2 VCR Sony/SVT-L200 2 Mounts Pelco/CM1300 28
Pressurized enclosure Pelco/EH8106 4 High security enclosure
Pelco/EH4014 8 Monitor mounts Pelco/MR4050 2 Cable WP/25815 2 Power
cable WP/25224 2 Transformers Amseco 28 Steel unistrut 1 The quote will
include sale of the above equipment, labor to install, and all
necessary equipment rental costs. All contractor personnel will be
required to attend a 'Construction Safety' briefing prior to commencing
any work. This briefing will be presented by the US Air Force Academy
and the duration would be 30 minutes. SCOPE All cameras are color
cameras fitted with lenses chosen to cover the desired areas. Cameras
and camera enclosures will be mounted on Pelco or Pelco equivalent
mounts rated to hold up to 25 pounds. All cameras will be mounted as
covertly as possible near the ceiling. Cable for the cameras, and
controls will be run wild and hidden in ceilings and walls where
possible. If the wires are to be installed in conduit, it will be the
resonsibility of the Government to provide the electrical power.
Swimming Pool: Four cameras will be placed in each corner near the
ceiling. Each camera will watch one quarter of the pool. Do to the
humid and warm environment, the cameras will need to be housed in
pressurized enclosures. The cameras and lenses will be positioned to
view the entire pool area. Basketball court: Like the pool, there will
be four cameras located near the ceiling. To avoid damage from balls
and other flying objects, the cameras will be enclosed in enclosures.
Each camera willcover one quarter of the court. Gym #2: Duplicate
coverage as the basket ball court. Multi Purpose room with balcony
#142: Install four cameras to cover this space. Racquetball court: Each
of the four courts will have an individual camera monitoring it through
the glass, rear wall. The cameras will be outside the courts to comply
with rules, and avoid being damaged. Cybex/Weight room #143: One
camera will be mounted high on the West wall. This location will cover
the room including the important entrance view. Anyone entering the
room would be frontally recorded. Aerobics room #122: A camera in the
Northeast corner of the room will cover the space, and all of the
entrances. Spinning room #230: One camera in the northwest corner will
cover most of the room, and the entrance. Hallways: Hallway #G05 will
have one camera mounted at the West end near the ceiling. Hallways
#110 and #151 will have two cameras facing towards each other. This
will completely cover the long hallway including the west outdoor
entrance,multipurpose room entrance,corridor entrance to the
racquetball courts, and East corridor opening leading to the lobby.
Hallway #202 will have two cameras similarly positioned to cover the
long space and it's exits. Control Station: The control station will be
installed in room #116 behind the reception desk. Camera images will be
displayed on two 20" color monitors. The monitors will be installed in
mounts and suspended from the ceiling to conserve space. Each monitor
will be capable of simultaneously displaying 16 camera views via
multiplexers. The multiplexer will allow the operator to manipulate and
call up any camera or cameras desired. All cameras will be recorded on
a time lapse recorder. A monitor feed will be extended into the
adjacent office allowing for easier monitoring. Posted 05/26/99
(D-SN335869). (0146) Loren Data Corp. http://www.ld.com (SYN# 0309 19990528\58-0012.SOL)
58 - Communication, Detection and Coherent Radiation Equipment Index Page
|
|