COMMERCE BUSINESS DAILY ISSUE OF JUNE 7,1999 PSA#2361CH2M Hill, Inc., 613 NW Loop 410, Suite 200, San Antonio, TX 78216 S -- PRIVATIZATION OF UTILITY SYSTEMS AT LITTLE ROCK AIR FORCE BASE,
ARKANSAS DUE 071699 POC For the U.S. Air Force: CH2M HILL, 613, NW Loop
410, Suite 200, San Antonio, TX 78216 POC: Laura Hein(lhein@ch2m.com),
Tel (210)377-3081 E-MAIL: Laura Hein, lhein@ch2m.com. PRIVATIZATION
UNDER 10 USC 2688, UTILITY SYSTEMS: CONVEYANCE AUTHORITY AT LITTLE ROCK
AIR FORCE BASE, ARKANSAS, SOL: N/A, DUE: 071699 POTENTIAL SOURCES
SOUGHT PURPOSE: The Air Force seeks to identify responsible potential
sources and obtain information in regards to privatization of utility
systems in accordance with 10 USC 2688, "Utility Systems: Conveyance
Authority". The Commander of Little Rock Air Force Base is seeking
interest and information specifically for the potential privatization
of the wastewater, natural gas, and electrical utility systems at
Little Rock Air Force Base, Arkansas. OBJECTIVE: Should privatization
result, the ownership of Little Rock Air Force Base's wastewater,
natural gas, and electrical utility systems, operation and maintenance
and obligation to continue to provide utility service for an
indefinite and ongoing period will transfer to a utility service
provider. All responsibility for maintaining reliable utility service,
including such items as environmental compliance,maintenance costs,
major system renovations, construction, equipment, manpower and
overhead costs will become the utility service provider's
responsibility. It is intended that the privatization will ultimately
reduce the Air Force's life-cycle costs for operating and maintaining
utility systems and services. SYSTEM DESCRIPTIONS: The following
information provided is only an estimate and is subject to change.
Little Rock AFB occupies 6,128 acres and is located approximately 17
miles northeast of Little Rock on Highway 67/167. There are 1,643
facilities on Little Rock AFB. The base population is comprised of more
than 19,000 people, most of which are the military that work on base
and their dependents. Sanitary Sewer The sanitary sewer collection
system consists of approximately 57 miles of collection piping, 95
percent of which consists of concrete gravity piping, and remainder
being PVC, VCP and CI piping. There are approximately 600 manholes. The
base has 12 lift stations it maintains which pumps into approximately
9.5 miles of force main. Flows from the sanitary collection system are
pumped to the City of Jacksonville, Arkansas for treatment. The flow
is metered at one central location. Natural Gas The natural gas
distribution system consists of approximately 20 miles of distribution
piping. There are approximately 14 miles of steel pipe and 6 miles of
PE pipe. Natural gas is delivered to the base through an 8-inch main
at 30 psig. Natural gas consumption is approximately 240 million cubic
feet annually with a peak day demand of 2.4 million cubic feet.
Electrical -- The primary power enters the facility from the south in
the area of the main gate. The 13.8/7.97 kV Y service to the main
switching station provides electricity to four (predominately overhead)
distribution feeders through distribution circuit reclosers located at
the main switching station. All feeders on base are phased with
numerous air break switches providing flexibility in switching. There
is approximately 327 miles of electric distribution line and the peak
demand is 17,000 to 19,000 kW. Street lighting is provided along the
primary roads with pole mounted lights. PROCEDURES: This request to
interested parties is for gathering information and is a required
component of a systematic process to evaluate the interested parties
under the Air Force's utilities privatization program. In order to
minimize costs both to potentially interested parties and the
government, this notice is being issued to determine the interest and
feasibility of proceeding with a formal request for proposals. Should
insufficient credible interest be identified for a privatization
action, it is highly likely that no formal solicitation will be issued.
SHOULD INTEREST BE DETERMINED SUFFICIENT, A FORMAL REQUEST FOR
PROPOSALS MAY BE FORTHCOMING. Small Business interests shall note the
FAR Part 19 Standard Industrial Codes (SIC) and Size Standards for the
utility systems identified in this announcement. Some, all, or any
combination of the following may apply. SIC/SS: 4911/4Million (M)
Megawatt hours, 4922/$5M, 4923/$5M, 4924/500, 4925/$5M, 4931/$5M,
4932/$5M, 4939/$5M, 4941/$5M, 4952/$5M, 4953/$6M, 4959/$5M, 4961/$9M,
4971/$5M. REQUESTED RESPONSE: Interested parties should provide a
statement of interest on company letterhead (not to exceed 20 pages in
length). The statement should include as a minimum the following
criteria: (1) specific utility system(s) of interest and desired
bundling/grouping of utilities to purchase; (2) capability and
experience in ownership, operation and maintenance of similar utility
systems; (3) financial capacity to purchase, expand and operate the
utility systems; (4) statement detailing the understanding of the
obligation to serve in regards to continuous utility service; (5)
conceptual rate plan (excluding numerical analysis or proposed rates),
i.e. will charges for utility service be made from existing rates or
from rates developed specifically for service at the individual
base(s); (6) ideas regarding conjunctive metering and billing for
service on base (excluding numerical analysis or proposed rates); (7)
discussion of your conceptual basis (excluding numerical analysis or
proposed price) for a proposed purchase price (capitalized earnings
value, replacement cost new less depreciation, original cost less
depreciation, or other); (8) statement detailing your understanding of
applicable state and local utility laws and your compliance
capability; (9) statement detailing your understanding of any existing
franchises and your ability to provide service given these conditions;
(10) statement detailing your understanding of federal, territorial,
and local environmental laws and regulations and familiarity and
experience with environmental compliance procedures and regulations for
the Arkansas and the U. S. Environmental Protection Agency; and (11)
business size (large, small, small-disadvantaged; 8(a); women-owned).
Elaborate proposals or pricing information is neither required nor
desired. Under no circumstances will cost data for the existing systems
be provided. Any innovative and new conceptual ideas to achieve the
stated objective are encouraged. If a site visit and the provision of
additional data are later determined necessary, notification will be
provided by way of an amendment to this announcement. It should be
noted that the RFIs for different Air Force Bases and utility systems
may be issued in the same time frame. A separate response to each RFI
is required. Please respond electronically as well as with hard copy.
The point of contact is Laura Hein(lhein@ch2m.com), Tel (210)377-3081.
Posted 06/03/99 (W-SN338582). (0154) Loren Data Corp. http://www.ld.com (SYN# 0095 19990607\S-0007.SOL)
S - Utilities and Housekeeping Services Index Page
|
|