Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF JUNE 22,1999 PSA#2372

Naval Surface Warfare Center, Code 1163, 300 Highway 361, Crane, IN 47522-5001

58 -- COMMUNICATION, DETECTION AND COHERENT RADIATION EQUIPMENT SOL N00164-99-Q-0197 DUE 071299 POC Ms. Diane Pearson, code 1173W7, telephone 812-854-5201, FAX 812-854-385; Ms. Luann Shelton, Contracting Officer WEB: click here to download copy of RFQ, http://www.crane.navy.mil. E-MAIL: click here to contact via e-mail, pearson_d@crane.navy.mil. This requirement is reserved for small business. The US Navy has a requirement for the fabrication of 5 each Radome Lens Polarizer Assemblies, Band 3 Receivers. Fabrication will be in accordance with Raytheon Drawing G256363. The following is a brief description of what is required: Interpret drawing per DOD-D-1000; Front surface skin to be quartz glass/epoxy single layer laminate per G277028, Sidewall, flange and inner surface multilayer skin to be fiberglass epoxy laminate with 35-55% resin content per MIL-P-2541., glass cloth per MIL-C-9084, Weave Optical, Dielectric filler may be used in sidewalls, flange and where shown, Lamination of polarizer shell including sidewalls, flange, grid sheets (FN 6, 7, and 8) and core material (-11 and 12) shall be per G27619; there shall be no sharp edges or corners; mask interior surfaces and flange mounting surfaces and paint exterior surfaces only. Apply primer MIL-P-85582 Type 1 Class N or MIL-P-23377, Type 1, Color 16473, top coat .001-.002 thick. Apply primerand paint per process specification G636625; acceptance inspection criteria shall be based on the following: measurement of at least of all the noted dimensions; use of fixture G276969-1. Fixture shall be placed along radome flange a minimum of 5.30 inside of flange edge (both ends) as shown in section A-A and also be placed at approximate center of radome. Radome interior contour is acceptable if fixture does not touch it when laying against radome flange and surface of radome is no more than .125 from surface of fixture. Also, there shall be no more than .060 variance with all three measurements taken into account. A minimum of a confidential security clearance is required. A firm fixed price contract will be awarded utilizing Simplified Acquisition Procedures. Delivery is required 10 months or sooner after issuance of award, with shipping terms FOB Destination, NAVSURFWARCEN DIV, Crane, IN. Inspection and acceptance of the unit(s) shall be performed by a representative of DCMC at source, prior to shipment. FAR part 12 procedures do not apply. The Government intends to award to the responsible contractor whose quotation is the most advantageous to the Government considering price and price-related factors. The offers will be evaluated on the following factors: Technical specification compliance, past performance and price. Technical specification compliance and past performance are equal, and when taken together are significantly more important than price. The Contractor shall provide past performance for same/similar products/specification with other Government Agencies, public or local Government for the past three years. All responsible sources may submit an offer with will be considered by the agency. The Request for Quote will be issued on or about 2 July 1999. Quotes are due no later than 12 July 1999. Inquiries may be submitted to Diane L. Pearson via e-mail at pearson_d@crane.navy.mil or fax number 812-854-3805. Posted 06/18/99 (W-SN344509). (0169)

Loren Data Corp. http://www.ld.com (SYN# 0286 19990622\58-0007.SOL)


58 - Communication, Detection and Coherent Radiation Equipment Index Page