Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF JUNE 23,1999 PSA#2373

United States Air Force, Air Education and Training Command, Lackland AFB Contracting Squadron, 1655 Selfridge Avenue, Lackland AFB, TX, 78236-5253

36 -- TRANSFORMERS, CONNECTORS, CABLES & SWITCHES SOL F41636-99-Q0735 DUE 071399 POC Lonnie Porter, Contract Specialist, Phone (210)671-1726, Fax (210)671-5063, Email lonnie.porter@lackland.af.mil -- Linda Richardson, Contract Specialist, Phone (210)671-1771, Fax (210)671-5064, Email WEB: Visit this URL for the latest information about this, http://www.eps.gov/cgi-bin/WebObjects/EPS?ACode=P&;ProjID=F41636-99-Q07 35&LocID=466. E-MAIL: Lonnie Porter, lonnie.porter@lackland.af.mil. This is a combined synopsis/solicitation for commercial items, prepared in accordance with the format in FAR subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; offers are being requested and a written solicitation will not be issued. This requisition is 100% set _aside for small business. This solicitation is issued as a request for quotations (RFQ). Submit written offers only (oral offers will not be considered), on requisitions F41636-99-Q-0735, this procurement is restricted to Small Business only. This solicitation document, incorporated provisions and clauses are those in effect through Federal Acquisition Circular 97-08, Standard Industrial Code 3612. Furnish the following as identified by manufacture, or like item: (1) 27 each Connector(s), 4 Point Deadbreak 600 Amp, Rubber junction with stainless steel mounting plate and back plate. Mfg By: Elastimold, Part number: 650J4. (2) 3 each Switch(s), Outdoor Padmounted 14.4 KV nominal 17.0 KV maxium, 95KV BIL, max amperes RMS, Fuse 200E, mini-rupter 600 amp cont. 3 phase, with key interlocks, fused storage and including 6 each- 3093 end fittings, 8 ea SMU-20 100Eamp # 612100 standard speed fuses. Mfg By: Mfg By: S&C Electric, Part Number: PME-9-65152R-C3-E3. (3) 12 each Kit(s), Scotchcast porcelain termination kit rated at 15 KVA for wire size 2 to 4/0 shielded wire or URD concentric neutral. Mfg By: 3M. Part number: 5903. (4) 90 each Connector(s), Universal 15 KV insert that fits between the padmount transformer dead front well bushing and the loadbreak elbow connector. Mfg By: General Electric, Part number: 9U02AAB001. (5) 11 roll Cable(s), High voltage power cable, MV-90 wet or dry, EPR/PVC, extruded shield, ethylene-propylene-rubber insulation. Mfg By: Westinghouse, Part number: 98-0100-97839-1000. (6) 132 each Connector(s), Loadbreak elbow type JT2B, Insulation diameter range 0.73-0.89 in., wire size # 1 stranded copper, with 15KV cable/175 mils installation, high strength bimetallic connector, current rating 200 amps. Mfg By: Elastimold, Part Number: 166LRRFB230. (7) 18 each Connector(s), non loadbreak elbow rated at 600 amps continuous load, used to connect cable to loadbreak insert bushing on padmounted transformer or a vaccum switch. Fits cable insulation diameter of 0.875 to 1.785 and conductor range of #2 to 750 MCM Copper. Mfg By: Elastimold, Part Number: 655LRH0240. (8) 7 each Coil(s), Cable high voltage power cable, EPR/PVC 15KV shielded, 133% insulation level copper, 4/0 stranded, 220 mil insulation thickness. Mfg By : Westinghouse, Part number: 98-0100-97843-1000. (9) 2 each Switch(s), 3 phase, padmounted, 2 way, NEMA 3 R enclosure, 3 ea 600 amp sets of 3 phase puffers disconnect, and 3 single phase 600 amp vaccum fused taps, electronic controls with _T_ TCC curves 15-300 Amp range, 3 phase gang handles. Mfg By: G&W Electric, Part number: GWPV143- 376-12-11. (10) 3 each Transformer(s), 300 KVA, Outdoor, 7620/13200 KV Primary, Oil Filled, Copper Wound, Dead Front, Loop Feed, with 6 Universal Primary Bushing Wells, 4 hole blade secondary, 2 Position Type _LBOR_ 200 amp oil switch, 95 KV bil with taps, Bayonet explusion fuses, thermometer and liquid gages, drain valve and 3 each spare fuses, 120/208 secondary, Mfg By: ABB, Part Number: ABB-300KVA-120/208 sec. (11) 21 each Transformer(s), 500 KVA, Outdoor, 7620/13200 KV primary, oil filled, copper wound, dead front, loop feed, with 6 universal primary bushing wells, 4 hole blade secondary, 2 position type _LBOR_ 200 amp oil switch, 95 KV bil with taps, Bayonet explusion fuses, thermometer and liquid gages, drain valve and 3 each spare fuses, 120/208 secondary. Mfr By: ABB, P/N: ABB-500KVA-120/208 sec. Address all Technical Questions to Edward Johnson (210) 671-3093. Delivery 30 days after award. FOB: Destination for delivery is; 1675 Gott Street, Building 5497, Lackland AFB, TX. 78236. The following FAR provisions apply to this acquisition. FAR 52.212-1, Instructions to Offerors -- Commercial Items, applies to this acquisition. The provisions at FAR 52.212-2, Evaluation -- Commercial Items, applies to this solicitation. The clause at FAR 52.212-5, Contract Terms and Conditions Required to Implement Statues or Executive Orders -- Commercial Items, applies to this solicitation. Specifically the following clauses, are applicable to this solicitation : FAR 52.222-26, Equal Opportunity; FAR 52.222-35, Affirmative Action for special disable and Vietnam ERA Veterans; FAR 52.222-36, Affirmative Action for Handicapped Workers. The clause at DFARS 252.212-7001, Contract Terms and Conditions required to implement Statues or Executive Orders applicable to Defense Acquisition of Commercial Items, applies to this solicitation. Specifically the following clauses, cited are applicable to this solicitation: DFARS 252.225-7001, Buy American Act and Balance of Payment Program. Offerors must include with their offer a completed copy of the provisions at FAR 52.212-3, Offeror Representations and Certifications -- Commercial Items, and DFARS 252-212-7000, Offerors and Representations and Certifications -- Commercial Items, applies to this solicitation. FAR 52.245-4, also applicable is DFARS 252.204-7004, Required Central Contractor Registration (CCR). CCR can be obtained by calling 1-800-334-3414. The CCR number must be obtained before award can be made. Award will be based on evaluation of: (a) meeting requirements, (b) lowest price, (c) responsible offer. Quotes must be sent in writing (oral offers will not be considered), to the POC indicated above. Quotes must be submitted not later than 2:00PM (CST), 08 Jul 99, and acceptance must be good for 60 days. Award will be made on or about 28 Jul 99. All responsible small business sources may submit an offer, which, if timely received will be considered by this agency.**** Posted 06/21/99 (D-SN345072). (0172)

Loren Data Corp. http://www.ld.com (SYN# 0246 19990623\36-0001.SOL)


36 - Special Industry Machinery Index Page