Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF JUNE 29,1999 PSA#2377

Puerto Rico Contracting Section, Attn: SOFB-DOC, Building 556, Fort Buchanan, PR 00934-5049

99 -- POWER, DISTRIBUTION AND SPECIALTY TRANSFORMERS SOL DAJN02-99-T-0083 DUE 070699 POC POC: Javier Cruz, Contract Specialist, (787)273-3559/Luis A. Torres, Contracting Officer. (787)273-3323 E-MAIL: Click here to contact the Contract Specialist via, jcruz@buchanan-emhl.army.mil. DESC: This is a combined synopsis/solicitation for commercial items prepared in a accordance with the format in subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being required and a written solicitation will not be issued.The solicitation no. is DAJN02-99-T-0083 and it is a request for quotations. Incorporated provisions are those in effect through Federal Acquisition Circular 97-11. The following specs are required: 10000kva outdoor substation,3phase 60 hertz,oil filled,65 degree C Rice,oil cooled,30 average/40 max.ambient,7.50 percent impedance with +/- ANSI standard tolerance,phase relation:DYN1,3300 feet max. altitude,68db (a)guaranteed sound level,on load tap changes, copper windings. HIGH VOLTAGE SPECS:High voltage 38000 Delta 250kv BIL,Taps:36100,37050,38950,39900,cover mounted bushings in ANSI segment 3,TBI bushings.LOW VOLTAGE SPECS: Low voltage 13200 Y/7620 110kV BIL,Cover mounted bushings in ANSI segment1, neutral bushing cover mounted bushing in ANSI segment 1,bulk type porcelain bushings.Tank SPECS: Formed base with jacking provisions, cork neoprene-all gauge gaskets,stainless steel ground pads,sealedaire oil preservation system,standard melded on flat tubular radiators, 15PS! tank design. FITTINGS SPECS:2" drain valve with 3/8" sampler valve,1" upper filter press valve,vacuum/upper filter press connection-1"cap. FINISH SPECS:ANSI 70 sky gray, 3mils, standard paint system.INSTRUMENTS:Dial type thermometer,liquid level gauge,pressure relief device,pressure vacuum gauge.Quotes must reference the item 0001 for (2) EA of the transformer.Shop drawing shall be provided for approval before manufacture.Equipment will be required for delivery at FORT BUCHANAN,PUERTO RICO 00934 not to exceed twenty (20) weeks after award of a contract.(Installation of the transformer is not included in this requirement.)FAR provision 52.212-1"Instructions to Offerors-Commercial Items" is applicable to this acquisition.FAR 52.212-5 "Contract Terms and Conditions Required to Implement Statutes or Executives Orders -- Commercial Items," is applicable to this order.Specific statutes and executive orders applicable are as follows:52.222-26, 52.222-35, 52.222-36, 52.222-37, 52.225-3, 52.232-33, 52.246-19,252.212-7000,and 252.212-7001. Offers are due no later than 4:00pm on July 06,1999 at the receptionist's desk of the Fort Buchanan Directorate of Contracting.Offerors should send their quotes to the following address:Department of the Army,ATTN:SOFB-DOC(J.CRUZ),PO BOX 34000,BUILDING 556, FORT BUCHANAN, PR 00934-3400.Quotes may also be sent via facsimile to Mr. Javier Cruz at (787)273-3751.Quoters are solely responsible for verifying that their facsimile was received on time.Quotes also must include DUNS number,cage code, and Central Contractor Registry (CCR) number. Interested parties are reminded that the Army cannot place an order with any offeror not registered in CCR. Information on registering in the CCR is available at the following web site:CCR.EDI.DISA.MIL/ Posted 06/25/99 (W-SN347404). (0176)

Loren Data Corp. http://www.ld.com (SYN# 0355 19990629\99-0007.SOL)


99 - Miscellaneous Index Page