COMMERCE BUSINESS DAILY ISSUE OF JULY 12,1999 PSA#2385Department of Commerce, NOAA, 200 World Trade Center, Room 209,
Norfolk, VA 23510-1624 D -- PROVIDE, INSTALL, AND MAINTAIN DEDICATED T3/DS3-COMPATIBLE
INTERNET CONNECTION SOL 52-EANE-9-00029 POC Lynne Phipps, Contract
Specialist, (757) 441-6881, Melvyn A. DesJarlais, Contracting Officer,
(757) 441-6647 WEB: 52-EANE-9-00029, http://www.easc.noaa.gov. E-MAIL:
Lynne Phipps, Lynn.B.Phipps@noaa.gov. The National Oceanic and
Atmospheric Administration (NOAA) has a requirement for a dedicated
Internet connection at the National Climatic Data Center (NCDC),
Asheville, NC. The Internet connection uses a dedicated circuit for the
communications portion of the service. The dedicated circuit is routed
from the NCDC LAN to a router at the provider's facility that is
directly connected to the backbone of the National Science Foundation
(NSF) Net. There shall be a maximum of one hop from the NCDC LAN to the
NSF Net backbone. At the NCDC LAN end of the connection, the service is
connected to a Cabletron SmartSwitch Router 8000. The contractor shall
be required to provide and install a T3/DS3-compatible CSU/DSU and
connect the CSU/SDU to the SmartSwitch router via an existing Cabletron
cable. The T3/DS3 connection shall have an initial bandwidth of 6Mbps
at a Committed Information Rate (CIR) of 3Mbps (1/2 CIR). The contract
will include options for future increases to the bandwidth up to
45Mbps priced in 3Mbps increments. The connection to the Internet shall
be at a network Operations Center (NOC) which shall be staffed 24 hours
per day, seven days a week, and be able to provide for immediate access
to the connection equipment and trouble-shooting by trained technical
staff. The contractor shall provide TCP/IP mail, file transfer, news
transfer, and virtual terminal access services to the Internet. The
contractor shall also provide preventative and remedial maintenance on
all equipment installed by the contractor. Remedial maintenance shall
begin within four (4) hours after notification that equipment or
software is inoperative. On- call maintenance shall also be provided
with response time of eight (8) working hours. Resident on-site
maintenance is not required. The period of performance for the
connection, services, and maintenance will include a base period
beginning upon acceptance of the equipment after installation through
9/30/00 with options for four (4) additional one-year periods. Copies
of the solicitation will only be provided in response to written or
faxed requests received directly from the requestor. Telephone requests
will not be honored. All responsible sources may submit proposal, which
will be considered by the agency. FAX number (757) 441-3786. Posted
07/08/99 (W-SN351824). (0189) Loren Data Corp. http://www.ld.com (SYN# 0031 19990712\D-0003.SOL)
D - Automatic Data Processing and Telecommunication Services Index Page
|
|