COMMERCE BUSINESS DAILY ISSUE OF JULY 14,1999 PSA#2387CECOM Acquisition Center Southwest Operations Office, Attn:
AMSEL-AC-CC-E-CB, Building 61801, Room 3210, Fort Huachuca, AZ
85613-6000 59 -- ELECTRICAL AND ELECTRONIC EQUIPMENT COMPONENTS DUE 081399 POC
Contract Specialist, Gay Moss, 520 538-7453!! E-MAIL:
mossg@emh1.hqisec.army.mil, mossg@emh1.hqisec.army.mil. MARKET
SURVEY/SOURCES SOUGHT. This is a Market Survey/Sources Sought
Announcement seeking to identify potential suppliers either Open Market
or GSA. The CECOM Acquisition Center, Southwest Operations Office is
seeking sources for Low Voltage Air Breakers to be use in Foreign
Countries. The products must be 220 volts and meet the Buy America Act.
LOW VOLTAGE AIR BREAKERS; 1) UL or IEC or VDE standard breakers; 2)
Three poles; 3) Insulation voltage 1000 volts; 4) Impulse voltage
8Kvolts; 5) Nominal voltage 660 volts; 6) Nominal voltage 400 volts
between phases; 7) Frequency 50 Hz.; 8) Nominal current 2000 Amps at
40'c; 9) Short-circuit 60Kamps in 400 volts 50 Hz.; 10) Short-circuit
making current 130 Kamps in 400 volts 50 Hz.; 11) RMS short time
withstand current 1 sec. 55 Kamps in 400 volts 50 Hz.; 12) 10000
mechanical operations, 5000 electrical operations at 400 volts and 1500
operations between maintenances; 13) Humidity of up to 95% at 45'c; 14)
4 auxiliary contacts; 15) One early contact (closing before the pole
contacts); 16) Withdrawable, mounted in cradle with slides; 17) Three
cradle positions CONNECTED, TEST, DISCONNECTED; 18) No automatic
tripping when drawn out of the cradle; 19) Vertical upright fastening
and horizontal fastening; 20) Connection of auxiliary circuits will be
with disconnectable clips; 21) In test position, will function without
affecting the inputs and outputs of breaker; 22) Handles to allow
manual arming of the breakers; 23) Flags to show their current
operation connected or disconnected; 24) Mechanical interlock in their
back; 25) Electrical interlock between every two breakers; 26) Trip
coils for 220 volts; 27) Proper connections for remote control from a
controller in the communication protocol RS23; 28) Option that will
enable locking them in disconnected mode. All information should be
sent to the CECOM Acquisition Center, Southwest Operations Office
CAC-S, Attn: AMSEL-AC-CC-E-CC-B (Gay R. Moss), Greely Hall, Building
61801, Fort Huachuca, Arizona 85613-5000.***** Posted 07/10/99
(W-SN352626). (0191) Loren Data Corp. http://www.ld.com (SYN# 0317 19990714\59-0006.SOL)