COMMERCE BUSINESS DAILY ISSUE OF JULY 22,1999 PSA#2393USDA-ARS-SAA, Richard B. Russell Center, 950 College Station Road,
Athens, GA 30605-2720 66 -- NEAR INFRARED REFLECTANCE TRANSMITTANCE CONTINUOUS SCANNING
SPECTROPHOTOMETER SOL RFQ-022-4384-99 DUE 080399 POC Elaine Wood,
706/546-3534 WEB: Click here to download a copy of 52.212-3,
www.nist.gov/admin/od/contract/repcert.html. E-MAIL: Click here to
contact the contracting officer by email, woode@ars.usda.gov. DESC:
This is a combined synopsis/solicitation for commercial items prepared
in accordance with the format in FAR Subpart 12.6, as supplemented
with additional information included in this notice. This announcement
constitutes the only solicitation; quotations are being requested and
a written solicitation will not be issued. The solicitation number
RFQ-022-4384-99 is issued as a request for quotations and incorporates
provisions and clauses that are in effect through FAC 97-09. The
standard industrial classification code is 3821. This solicitation is
issued on an unrestricted basis. Application of instrument: Near
infrared reflectance-transmittance continuous scanning
spectrophotometer for determination of phosphorus content in ground
sugarcane tissue and juice extracted from sugarcane stalks (see
specifications below). 1.160 mini-sample cups and holders to contain
ground sugarcane tissue samples. 2 Suitable containers for liquid
samples. 3.Sealed plant standard in a mini-sample cup. 4.Computer to
control NIR (see specifications below). 5.Uninterruptable power supply
(see specifications below). 6.Software to communicate between computer
and NIR and to calculate regression equations for sample analysis (see
further specifications below). 7.Training on general use of NIR system
to include subjects such as use of software, calibration, and routine
maintenance. 8.One year warranty with 72 hour service during warranty
period. 9.On-site installation at USDA-ARS Sugarcane Field Station in
Canal Point, FL. 10.Any deviations from specifications must be noted by
bidder. Instrument Specifications 1.Grating spectrophotometer with a
scanning monochromator capable of identifying wavelengths from 400 to
2500 nm at 2 nm increments. 2.Photometric range of 3.0A. 3.Working
range of 4.0A. 4.Typical noise at 0.0 absorbance 1300-1700 nm; < 14
A 1700-2400 nm; < 20 A. 5.Scan Speed of at least 1.8 scans per
second. 6.Detectors: 7.Lead sulfide at 1100-2500 nm 8.Silicon at
400-1100 nm. 9.Wavelength accuracy Based on instrument-to-instrument
repeatability: 0.15 nm Based on currently accepted wavelength
standards: 0.30 nm. 10.Instrument wavelength precision Short and long
term: 0.01 nm. 11.Linearity: 1% of reading. 12.Stray light of less than
0.1% at 2300 nm. 13.Spectral bandwith: 10 nm plus or minus 1 nm in
reflectance. 8.5 nm plus or minus 1 nm in transmission. 14Operating
temperature of 15-32 degrees Celsius. 15.Spinning sample module that
physically rotates coarse-ground samples. 16.Suitable accessories to
handle liquid samples. 17.Standard power reflectance cells.
18.Forage/grain sealed reference sample holder. 19.Appropriate RS-232
ports or other widely used method to connect to and be controlled by an
IBM or IBM compatible computer. 20.Continuous scanning without physical
or internal changes. 21.Internal standardization for each sample
analyzed. 22.Standardized to a standard master monochromator.
23.Modular in design. 24.Capable of upgrading to a fiber-optic probe
with up to 1 km cable length. 25.Must be capable of responding with
both reflectance and "true" transmission based on a keystroke from the
controlling computer. Computer At least 500 MHz with Pentium III
processor, at least 10 gigabyte hard drive, at least 128 meg ram, at
least 2 com ports and 1 printer port, 1 floppy drive and 1 zip drive,
and at least 17" color monitor. All other components such as keyboard,
mouse, etc. should be as generally are standard with the Pentium III
processor. 1.Color inkjet printer capable of at least 600 dpi
resolution. Software 1.Calibration development for open and closed
sample populations of samples collected. 2.Able to convert reflectance
spectra to log 1/R and calculate first, second, third, and fourth
derivatives. 3.Software compatible to Windows 98 to make calibrations
in MLR, PLS, and single wavelengths, calculate Mahalanoma numbers (H
statistic), perform calibrations on the fly. Uninterruptable Power
Supply Capable of maintaining constant power to the NIR and computer
for at least 15 minutes when electrical power is interrupted. 1.Capable
of protecting NIR and computer to damage from power surges. Delivery is
required within 8 weeks ARO. Delivery is FOB Destination to USDA, ARS,
Canal Point. Descriptive literature showing the quoted item meets or
exceeds all specifications included herein must accompany the
quotation. The government anticipates award of a contract resulting
from this solicitation to the responsive/responsible offeror whose
offer conforms to the solicitation and is most price advantageous to
the government. The provision at 52.212-2, Evaluation-Commercial Items,
applies to this acquisition. The contracting officer will make award
based on price and price-related factors. Offerors shall include a
completed copy of the provision at FAR 52.212-3,
Offeror/Representations and Certifications-Commercial Items, with its
proposal. Far 52.212-4, Contract Terms and Conditions-Commercial Items,
applies to this acquisition. FAR 52.212-5, Contract Terms and
Conditions Required to Implement Statues or Executive Orders --
Commercial Items, applies to this acquisition. The following FAR
clauses cited in 52.212-5 are applicable to this acquisition: 52.203-6;
52.203-10, 52.219-8; 52.222-26; 52.222-35, 52.222-36, 52.222-37;
52.225-3; 52.222-18; 52.225-21. The contractor shall extend to the
Government the full coverage of any standard commercial warranty
normally offered in a similar commercial sale, provided such warranty
is available at no additional cost to the Government. Acceptance of the
standard commercial warranty does not waive the Government's rights
under the Inspection clause nor does it limit the Government's rights
with regard to the other terms and conditions of this contract. In the
event of a conflict, the terms and conditions of the contract shall
take precedence over the standard commercial warranty. The contractor
shall provide a copy of its standard commercial warranty (if
applicable) with its response. Responses are due 15 days from the date
this notice is published in the CBD by 4:00 pm local time, August 3,
1999 at USDA Agricultural Research Service, 950 College Station Rd,
Athens, GA 30605-2720 (or POB 5677, Athens, GA 30604-5677). POC Elaine
Wood, Contract Specialist, 706/546-3534 or fax 706/546-3444. Posted
07/20/99 (W-SN356625). (0201) Loren Data Corp. http://www.ld.com (SYN# 0391 19990722\66-0005.SOL)