COMMERCE BUSINESS DAILY ISSUE OF JULY 22,1999 PSA#2393Talisman Partners, Ltd., 5460 South Quebec St., Suite 100, Englewood,
Co 80111-1916 S -- PRIVATIZATION UNDER 10 USC 2688, UTILITY SYSTEMS: CONVEYANCE
AUTHORITY AT SAVANNAH IAP (ANG), SAVANNAH, GA. DUE 082099 POC Scott
Beckman or Joel Theis, 303/771-3103 E-MAIL: Email to POC,
sbeckman@talpart.com. The Air Force seeks to identify responsible
potential sources and obtain information in regards to privatization of
utility systems in accordance with 10 USC 2688, "Utility Systems:
Conveyance Authority". The Air Force is seeking interest and
information specifically for the potential privatization of the
electrical distribution and wastewater collection systems at Savannah
IAP (ANG), Georgia. This includes off-base sites at the 224 Joint
Communications Squadron located at Brunswick, GA, and the Savannah Air
Guard Station at Savannah, GA. OBJECTIVE: Should privatization result,
the ownership of the Savannah IAP (ANG) electrical distribution and
wastewater collection systems, operation and maintenance and obligation
to continue to provide utility service for an indefinite and ongoing
period will transfer to a utility service provider. All responsibility
for maintaining reliable utility service, including such items as
environmental compliance, maintenance costs, major system renovations,
construction, equipment, manpower and overhead costs will become the
utility service provider's responsibility. It is intended that the
privatization will ultimately reduce the Air Force's life-cycle costs
for operating and maintaining utility systems and services. SYSTEM
DESCRIPTIONS: The following is provided only to give an approximation
of the size, scope and general description of the system(s). Any
numbers should only be used for estimating purposes. The following
system parameters are approximations: Savannah IAP: Base Size: 239
Acres, 144 Buildings, no Family Housing Units. Savannah IAP Electrical
System: 13,200 Volt Distribution System Primary Distribution
(Underground): 51,015 LF. Secondary Distribution (Overhead): 6,150 LF.
Secondary Distribution (Underground): 2,472 LF Savannah IAP Wastewater
Collection: Sanitary Sewer Mains: 4,270 LF Sewage Pump Station: 3 Each
Savannah AGS: Base Size: 20 Acres, 5 buildings, no Family Housing
Units. Savannah AGS Electrical System: 13,200 Volt Distribution System
Secondary Distribution (Overhead): 300 LF. No primary distribution.
Savannah AGS Wastewater Collection: No Sanitary Sewer Mains. Glynco
ANG: Base Size: 15 acres, 4 buildings, no Family Housing Units. Glynco
ANG Electrical System: 13,200 Volt Distribution System. Primary
Distribution (Underground): 1,118 LF. Secondary Distribution
(Underground): 170 LF. Glynco ANG Wastewater Collection: Sanitary
Sewage Main: 5,820 LF. PROCEDURES: This request to interested parties
is for gathering information and is a required component of a
systematic process to evaluate the interested parties under the Air
Force's utilities privatization program. In order to minimize costs
both to potentially interested parties and the government, this notice
is being issued to determine the interest and feasibility of
proceeding with a formal request for proposals. Should insufficient
credible interest be identified for a privatization action, it is
highly likely that no formal solicitation will be issued. SHOULD
INTEREST BE DETERMINED SUFFICIENT, A FORMAL REQUEST FOR PROPOSALS MAY
BE FORTHCOMING. Small Business interests shall note the FAR Part 19
Standard Industrial Codes (SIC) and Size Standards for the utility
systems identified in this announcement. Some, all, or any combination
of the following may apply. SIC/SS: 4911/4Million (M) Megawatt hours,
4922/$5M, 4923/$5M, 4924/500, 4925/$5M, 4931/$5M, 4932/$5M, 4939/$5M,
4941/$5M, 4952/$5M, 4953/$6M, 4959/$5M, 4961/$9M, 4971/$5M. REQUESTED
RESPONSE: Interested parties should provide a statement of interest on
company letterhead (not to exceed 20 pages in length). The statement
should include as a minimum the following criteria: (1) capability and
experience in ownership, operation and maintenance of similar utility
systems, (2) financial capacity to purchase, expand and operate the
utility systems; (3) statement detailing the understanding of the
obligation to serve in regards to continuous utility service; (4)
statement detailing the legal right to serve, own, operate, and
maintain utility systems within state laws and an understanding of any
applicable federal, territorial and local utility laws, regulations or
franchise requirements affecting utilities in the territory, and
capability of complying with such requirements; and (5) statement
detailing the understanding of federal, territorial, and local
environmental laws and regulations and familiarity and experience with
environmental compliance procedures and regulations for the State of
Georgia and the U. S. Environmental Protection Agency. Elaborate
proposals or pricing information is neither required nor desired. Under
no circumstances will cost data for the existing systems be provided.
Any innovative and new conceptual ideas to achieve the stated objective
are encouraged. If a site visit and the provision of additional data
are later determined necessary, notification will be provided by way of
an amendment to this announcement. It should be noted that RFIs for
different utility systems may be issued in the same time frame. A
separate response to each RFI is required. The point of contact is
Scott Beckman or Joel Theis, 303/771-3103. Posted 07/20/99
(W-SN356504). (0201) Loren Data Corp. http://www.ld.com (SYN# 0119 19990722\S-0016.SOL)
S - Utilities and Housekeeping Services Index Page
|
|