|
COMMERCE BUSINESS DAILY ISSUE OF JULY 23,1999 PSA#2394DHHS/PHS/FDA/Office Of Facilities, Acquisition, And Central Services,
Division of Contracts and Program Management, HFA-512(COB), 5600
Fishers Lane, Rockville, MD 20857 66 -- DYNAMIC MECHANICAL ANALYZER, DIFFERENTIAL SCANNING CALORIMETER
AND ACCESSORIES SOL A66011 DUE 080699 POC Patricia Wright, Contract
Specialist (301) 827-7163 The Food and Drug Administration intends to
award a Purchase Order on a sole basis to Rheometric Scientific, One
Possumtown Road, Piscataway, New Jersey 08854. Rheometric Scientific
will provide the following equipment: Dynamic Mechanical Analyzer
(DMTA-V), Differential Scanning Calorimeter (DSC), 2 each of LN2 kit
(low Pressure LN2 Dewar) DMTA-LN2, DMTA-INVERT, and HP-Desk Jet
Printer. The Dynamic Mechanical Analyzer will be used to study polymer
degradation with respect to mechanical properties and would help us
design accelerated tests for shelf life studies. The Differential
Scanning Calorimeter will be used to study polymer degradation and
changes in morphology that affect the performance of devices containing
polymeric compounds. The instrument is considered unique in that it has
the ability to: 1. Multiple modes of sample deformation: tension,
bending, compression and shear in pure form. 2. Ability to perform
shear measurements in a horizontal mode to prevent sample sagging or
leaking in the case of gels. 3. Ability to make measurements on samples
immersed in a liquid environment. 4. Minimum number of Dewars or liquid
nitrogen transfers for cooling both the DMA and DSC. 5. Wide test
frequency range. 6. The DMTA V can operate in a horizontal mode and has
the widest frequency range from 1.6 x 10 to 200 Hz. The lowest
frequency corresponds to a period of 11 days that could approximate
some slow varying storage condition. Rheometric will deliver and
install the instrument to FDA. Rheometric shall warrant normal
operation of equipment and provide any needed maintenance for a period
of one year following installation. An award will be made fifteen (15)
days from date of this notice. This is not a request for quotes,
however, sources may submit descriptive literature which fully
demonstrate their product meets the brand name specification which
shall be considered by the agency. This sole source procurement is
being awarded as a simplified acquisition in accordance which FAR
Subpart 13.5. Posted 07/21/99 (W-SN357146). (0202) Loren Data Corp. http://www.ld.com (SYN# 0408 19990723\66-0026.SOL)
66 - Instruments and Laboratory Equipment Index Page
|
|