Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF JULY 27,1999 PSA#2396

Bid Office, SPAWARSYSCEN, Code D21B, 53570 Silvergate Avenue, Bldg. A33, Room 0061, San Diego, CA 92152-5112

61 -- ELECTRIC WIRE & POWER & DISTRIBUTION EQUIPMENT SOL N66001-99-Q-0152 DUE 082699 POC Purchasing Agent, Angela King, D212, (619)553-5829. Contracting Officer, Melissa Dolan, D212, (619)553-6336. This is a combined synopsis/solicitation prepared in accordance with the format in the Federal Acquisition Regulation, supplemented with information included in this notice. This solicitation incorporates provisions and clauses at FAR 52.213-4 Terms and Conditions -- Simplified Acquisitions (Other Than Commercial Items) (FEB 1998), and any others that are applicable and in effect through the current Federal Acquisition Circular (FAC) and the Defense Acquisition Circular. It is the contractors responsibility to be familiar with all applicable clauses and provisions. No RFQ will be prepared or made available for distribution. While price will be a significant factor in the evaluation of offers, award will be based on responsive, responsible, technically acceptable offers received in response to this CBD advertisement.. Competitive awards may be based on the evaluation criteria stipulated in the Red, Yellow, Green (RYG) Contractor Evaluation System. The evaluation criteria is available upon request. Specifications for Uninterruptible Power System (UPS): This is a request for a new UPS to replace an existing system. The UPS distributes conditioned power to a Software Development Lab. The critical load is powered by an inverter, which obtains its power from a battery backup system in the event of a utility power outage. This system is required to provide reliable power distribution 24 hours a day, 365 days a year. The minimum specification for this unit are as follows: 1. Minimum 36kVA/24kW, rated 400 Hz Uninterruptible Power System (UPS), 2. All bussbars, wiring and transformers shall be made of copper, 3. Input voltage -- 480 VAC, 3 Phase, 3 Wire plus ground, 4. Output voltage -- 208 VAC, 3 Phase, 3 Wire plus ground, 5. Input Harmonic Filter/Power Factor Correction, 6. Remote Alarm Summary Panel, 7. Power Monitoring System, 8. Battery Pack System -- 15 minutes at 24kW, 9. Battery Monitoring System, 10. Seismic mounted components, in NEMA type I enclosures, 11. Year 2000 compliant. Installation forthe above unit to include the following: 1. Demo, remove and dispose of existing 400 Hz UPS and batteries (64), 2. Remove unused power/battery wiring conduit, 3. Install new UPS, 4. Connect input and output feeders, 5. Connect controls and alarms, 6. Install and attach battery components, 7. Maintain space habitability. Location of work to be done: SPAWAR System Center San Diego. Questions may be directed to Angela King, E-mail Kinga@spawar.navy.mil, Phone (619)553-5829, Fax (619)553-1062. Interested parties are invited to respond to this synopsis. Facsimile quotations are acceptable and must be received on or before the COB on the closing date stated above. The applicable Standard Industrial Code (SIC) and Size Standard is: 5063/100. See numbered Note 1. Posted 07/23/99 (W-SN358145). (0204)

Loren Data Corp. http://www.ld.com (SYN# 0343 19990727\61-0005.SOL)


61 - Electric Wire and Power and Distribution Equipment Index Page