Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF AUGUST 2,1999 PSA#2400

Department of the Air Force, Air Combat Command, 1st CONS, 74 Nealy Avenue, Suite 100, Langley AFB, VA, 23665

43 -- COMPRESSOR SOL F4460099T0555 DUE 081299 POC Betty Sharp, Purchasing Agent, Phone 757-764-4916, Fax 757-764-7447, Email betty.sharp@langley.af.mil -- Yolanda White-Woolaston, Contract Specialist, Phone 757 764-7382, Fax 757 764-7447, Email WEB: Visit this URL for the latest information about this, http://www.eps.gov/cgi-bin/WebObjects/EPS?ACode=P&;ProjID=F4460099T0555 &LocID=203. E-MAIL: Betty Sharp, betty.sharp@langley.af.mil. DESC: This is a synopsis/solicitation for a commercial item prepared in accordance with (IAW) the format in the Federal Acquisition Regulation (FAR) Subpart 12.6 as supplemented with additional information included in this notice. This announcement constitutes the only solicitation: a written solicitation will not be issued. PAPER COPIES OF THIS SOLICITATION WILL NOT BE AVAILABLE. The solicitation will be issued on the world-wide-web using Electronic Posting System (EPS) and the Commerce Business Daily (CBD). ( ii ) Solicitation F44600-99-T0555 is issued as a Request for Quote (RFQ) using Simplified Acquisition Procedures under the test program for certain commercial items found at FAR 13.5. ( iii ) The solicitation document incorporates provisions and clauses that are in effect through Federal Acquisition Circular (FAR) 97-11 and Defense Acquisition Circular 91-13. It is the contractor_s responsibility to be familiar with all applicable clauses and provisions. (iv) The 1st Contracting Squadron requests responses from qualified sources capable of providing Air Compressor capable of producing, at a minimum, 1200 PSIG at a flow rate of 30 SCFM. The compressor should include the following features: Motor 25hp or greater, 460v/3 phase/60hz _Inlet filter-Water cooled intercoolers and after coolers-Interstage and final stage condensate separators-Interstage and final stage safety relief valves-V-belt drive with safety guard-Discharge check valve-Interstage and final stage air pressure gauges-Oil pressure gauge-Hour meter-Emergency stop button-Power-on switch with indicator lamp-Automatic start/stop air pressure switch with indicator lamp-Low oil pressure switch with warning lamp-High temperature switch with warning lamp-Low water flow switch with warning lamp-Automatic condensate drain system-Magnetic starter and control system-Water control shutoff valve-Thermostatic control valve-Two dial thermometers-Water pressure gauge; Will require wiring to existing electrical disconnect box and connection to an existing cascade airline system; Air storage system capable of maintaining at least 1200 PSIG and 30 SCFM at the termination point of the cascade air system is required. This storage system should include a high-pressure air regulator and gauge. Storage rack and connection to the air system is required. (v) Delivery: Date of delivery will be 30 days after receipt of order, an earlier delivery date is desired. Place of delivery and Acceptance for providing the compressor will be 581 Worley Road Langley AFB, VA 23665. Responsibility and Inspection: Unless otherwise specified in the purchase order, the supplier is responsible for the performance of all inspection requirements and Quality Control. (vi) The following FAR provisions and clauses are applicable to this procurement: 52.212-1, Instructions to Offerors-Commercial Items (JUN 1999) is hereby incorporated by reference. (vii) Solicitation provision at FAR 52.212-2, Evaluation Commercial Items (JAN 1999) is hereby incorporated by reference. (viii) Offerors are reminded to include a completed copy of the provision at 52.212-3, Deviation Offeror Representations and Certificates Commercial Items (JUN 1999) and 252.212-7000, Offeror Representations and Certifications Commercial Items (NOV 1995) with its offer. Contact our point of contact for full text if necessary. (ix) Clause 52.212-4, Contract Terms and Conditions Commercial Items (MAY 1999) is hereby incorporated by reference. (x) Clause 52.212-5, Contract Terms and Conditions required to Implement Statues or Executive Orders Commercial Items (MAY 1999), is hereby incorporated by reference. The following paragraphs apply to this solicitation and any resultant contract 39.10-6, 52.203-6, 52.203-8, 52.203-10, 52.211-6, 52.217-5, 52.217-6, 52.217-7, 52.222-26, 52.222-35, 52.222-36, 52.222-37, 52.247-34 52.247-64. (xi) Additional Contract Terms and Conditions applicable to this procurement are: Clause 252.212-7001, Contract Terms and Conditions required to Implement Statues or Executive Order Applicable to Defense Acquisitions of Commercial Items (JAN 1999), is hereby incorporated by reference. The following paragraphs apply to this solicitation and any resultant contract 252.204-7001, 252.204-7004, 252.211-7003, 252.225-7001. (xii) The Defense Priorities and Allocations Systems (DPAS) assigned rating for this procurement is C9E. ( xiii) There are no applicable Commerce Business Daily numbered notes. (xiv) Award will be made to the lowest priced, technically acceptable, responsible, responsive offeror who demonstrates compliance with the requirements of this solicitation and all referenced clauses. Offerors shall include both unit price and total price with their quote. (xv) Submit all quotes to 74 Nealy Ave Langley AFB, VA 23665. (xvi) This announcement will close 3:00PM (EST) 12 Aug 1999. (xvii) Contact Betty Sharp at 757-764-4924, fax 757-764-7447 or email: betty.sharp@langley.af.mil for information. Posted 07/29/99 (D-SN360841). (0210)

Loren Data Corp. http://www.ld.com (SYN# 0295 19990802\43-0001.SOL)


43 - Pumps and Compressors Index Page