COMMERCE BUSINESS DAILY ISSUE OF AUGUST 4,1999 PSA#2402Supply Contracting Office, Marine Corps Air Station Miramar, P.O. Box
452007, San Deigo, CA 92145-2007 W -- LEASING RENTAL OF OFFICE SPACE TRAILER SOL M6786599T0038 DUE
081899 POC Carolyn M. Knight (858)557-1553 WEB: PROCUREMENT,
WWW.USA.GOV/PROCUREMENT/INDEX.HTML. E-MAIL: KNIGHTCM,
KNIGHTCM@MAIL.MIRAMAR.USMC.MIL. THIS IS A COMBINED SYNOPSIS/SOLICTATION
FOR COMMERICAL ITEM PREPARED IN ACCORDANCE WITH THE FORMAT IN FAR PART
12.6, AS SUPPLEMENTED WITH ADDITIONAL INFORMATION INCLUDED THIS
NOTICE.THIS PROCUREMENT IS SET ASIDE FOR SMALL BUSINESS.THIS
SOLICTATION WILL DOCUMENT AND INCORPORATED PROVISIONS AND CLAUSES ARE
THOSE ACQUISITION CIRCULAR 91-11. THE GOVERNMENT INTENDED TO LEASE/RENT
5000 SQ FT TRAILER UNDER THE SIMPLIFIED ACQUISITION
PROCEDURES.MOBILIZATION,DELIVERY TO THE SITE AND SETUP. RENTAL OF ONE
TRAILER -- 12 MONTHS (SET UP FOR MONTHLY PAYMENTS) DE-MOBILIZATION --
DISASSEMBLE AND REMOVAL FROM GOVERNMENT PROPERTY. 5000 SQ FT MINIMUM OF
GENERAL OFFICE SPACE, ASSEMBLED AND READY TO USE. BROKEN UP INTO NO
MORE THAN TWO STRUCTURES (ONE STRUCTURE IS PREFERRED). UNITS MUST BE
CAL DOH APPROVED BEARING INSIGNIA. SKIRTED AROUND THE ENTIRE
FACILITY(S). STAIRS AT ALL EXISTS. STRUCTURE(S) TO HAVE A MINIMUM 40
LBS/SF LIVE LOAD RATING. WOMEN'S RESTROOM WITH TWO TOILETS AND ONE
LAVATORY. MEN'S RESTROOM WITH TOILETS, ONE URINAL, THREE LAVATORIES.
ONE JANITOR'S CLOSET OF APPROX 25 SQ FT WITH A DEEP SINK ( NOTE IF THE
CONTRACTOR PROVIDES TWO STRUCTURES, THIS REQUIREMENT SHALL BE REPEATED
IN THE SECOND STRUCTURE). ALL INTERIOR PLUMBING SHALL CONFORM TO
UNIFORM PLUMBING CODE (UPC). TWO PRIVATE OFFICES OF APPROX 100 SQ FT
EACH. HVAC THROUGHOUT (HEATING AND COOLING). ALL HVAC TO SHALL CONFORM
TO THE UNIFORM MECHANICAL CODE (UMC). CARPETING THROUGHOUT WITH THE
EXCEPTION OF THE RESTROOMS AND JANITOR'S CLOSET, WHICH WILL HAVE
APPROPRIATE WATER RESISTANT FLOORING. TIE DOWNS PER MANUFACTURES
INSTRUCTIONS. LIGHTING APPROPRIATE FOR AN OFFICE USE. WATER AND SEWER
SHALL TERMINATE IN THE VICINITY OF GOVERNMENT INSTALLED UTILITIES (
SITE MAP FOR LOCATION AND DEPTH WILL BE PROVIDED). STRUCTURE SHALL HAVE
A SINGLE POINT OF CONNECTION (PER STRUCTURE) FOR ELECTRICAL DROP.
GOVERNMENT WILL PREFORM ACTUAL ELECTRICAL CONNECTION. CONTRACT
REQUIREMENT IS ALL INTERIOR SYSTEMS TO INCLUDE PANELS AND WEATHERHEAD.
INTERIOR ELECTRICAL -- ONE DUPLEX OUTLET (GFI) IN EACH RESTROOM AND
THE JANITOR CLOSET. DUPLEX OUTLETS ON ALL WALLS (EXCEPTING THE INTERIOR
FACES OF RESTROOMS), MAXIMUM DIMENSION BETWEEN OUTLETS ON WALLS SHALL
BE 12 FT. ALL COMMON SPACES (AREAS OTHER THAN THE PRIVATE OFFICES,
RESTROOMS AND JANITOR'S CLOSET)HAVE FLUSH MOUNTED DOUBLED DUPLEX
OUTLETS INSTALLED IN THE FLOOR. MAXIMUM SPACING BETWEEN THESE OUTLETS
IS 12 FEET ON CTR. ALL ELECTRICAL SHALL BE IN ACCORDANCE WITH THE
NATIONAL ELECTRIC CODE (NEC). TELEPHONE SYSTEM SHALL CONFORM WITH THE
EIA568B CAT STANDARD. NO TELEPHONE IN THE RESTROOMS OR JANITOR'S
CLOSET. PRIVATE OFFICE SPACES ARE TO HAVE A TWO TELEPHONE OUTLETS EACH,
LOCATED APPROPRIATELY. WALLS IN THE COMMON SPACES ARE TO HAVE A
TELEPHONE OUTLETS AT EACH DUPLEX RECEPTACLE. IN THE COMMON SPACES, TWO
TELEPHONE OUTLETS AT ARE TO BE FLUSH MOUNTED IN CLOSE PROXIMITY
(WITHIN 12 TO 18 INCHES) OF EACH DBL DUPLEX ELECTIRCAL OUTLET. PROVIDED
A 4' BY 4'-3/4" PLYWOOD BACKBOARD (PER STRUCTURE). EACH OUTLET TO
TERMINATE AT THE BACKGROUND AND TERMINATER WITH A 66 BLOCK TERMINAL.
ALL DATA TERMINATIONS/CABLING TO CONFORM WITH THE TIA/EIA568A (I.E. DTE
TO DCE) CAT 5 WIRING STANDARD. NO DATA IN THE RESTROOMS OR JANITOR'S
CLOSET. PRIVATE OFFICE SPACES ARE TO HAVE TWO DATA OUTLETS EACH LOCATED
APPROPRIATELY. THIS DATA LOCATION MAY BE CO-LOCATED WITH THE TELEPHONE
OUTLET. WALLS IN THE COMMON SPACES ARE TO HAVE A DATA OUTLET AT EACH
DUPLEX RECEPTACLE. IN THE COMMON SPACE TWO DATA OUTLETS ARE TO BE FLUSH
MOUNTED IN CLOSE PROXIMITY (WITHIN 12 TO 18 INCHES) OF EACH DBL DUPLEX
ELECTRICAL OUTLET. PROVIDE A MDF WITH UTP CATEGORY 5 PATCH PANEL (PER
STRUCTURE). EACH OUTLET TO BE WIRED TO THE MDF AND TERMINATE IN
ACCORDANCE WITH ITEM 21A. EACH DATA OUTLET SHALL BE LABELED TO IDENTIFY
ITS CORRESPONDING LOCATION ON THE PATCH PANEL IDENTIFIED IN ITEM 21F.
EACH STRUCTURE SHALL HAVE A SEPARATE 3" WEATHERHEAD FOR THE PURPOSE OF
TELEPHONE AND DATA. THE GOVERNEMENT WILL PERFORM MINOR MAINTENANCE TO
INCLUDE JANITORIAL SERVICES, REFUSE COLLECTION AND ROUTINE MAINTENANCE
SUCH AS FILTER REPLACEMENT, BULB REPLACEMENT AS WELL AS EFFORTS OF LESS
THAN 16 HOURS DURATION. CONTRACTOR SHALL WARRANTEE THE MAJOR SYSTEMS
SUCH AS ROOFING, HVAC AND STRUCTURE FOR DURATION OF THE LEASE.BASE BID:
MOBILIZATION DELIVERY TO THE SITE, SETUP. RENTAL: ONE -- 12 MONTHS AND
DEMOBILIZATION DISASSEMBLE AND REMOVAL FROM GOVERNEMENT SITE. THE
ANTICIPATED AWARD DATE IS 99 AUGUST 20. ALL RESPONSIBLE QUOTATIONS MAY
BE SENT FACSIMILE OR VIA MAIL. FACSIMILE NUMBER 858-577-1492/e.g.,"SEE
NOTE(S)22 AND 23". Posted 08/02/99 (W-SN362024). (0214) Loren Data Corp. http://www.ld.com (SYN# 0102 19990804\W-0001.SOL)