Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF AUGUST 11,1999 PSA#2407

U.S. Army Corps Of Engineers -- Mobile, Contracting Division, CESAM-CT (109 St. Joseph Street 36602) PO Box 2288, Mobile, AL 36628-0001

13 -- ARMORY VAULT SOL DACA01-99-T-0205 DUE 083099 POC Linda D . Stanley (334) 441-5539 or Toni Carney (334) 441-5581 WEB: http://www.sam.usace.army.mil/sam/ct/cgi-win/projlist.exe, http://www.sam.usace.army.mil. E-MAIL: cesam.plansroom@sam.usace.army.mil, http://cesam.plansroom@sam.usace.army.mil. Stand alone high security storage facilities for conventional small arms weapons in accordance with scope of work and quidance from purchase specification NSWC 3046-93-2 dated 24 Oct 97. Purchase specification NSWC 3046-93-2 is necessary for the contractor to properly prepare and submit their quotation. Quantity: One (1) each with option quantity of two each (maximum quantity of three (3). Arms vault shall be approximately 512 sq. ft., constructed in one piece and the exterior width shall not exceed 16 feet, exterior length shall not exceed 40 feet, interior height is a minimum of seven (7) feet, exterior height is a maximum of eight (8) feet. Must be able to accept two (2) M16A2 arms racks double stacked. Vault shall have only one (1) door. Vault shall have a bullet resistant enclosure over AC unit. Vault shall be equipped so that it can be anchored to concrete pad. Exterior of vault shall be painted white. Vault shall have four (4) 110 volt quad receptacles. Electrical receptacles shall be located inthe center of each wall. NFPA 780 lightening protection is required. Vault shall be provided with 100 AMP, 220, single phase exterior disconnect. Interior lights shall be 6-8 feet long duplex dust and vapor resistant fluorescent lights. Telephone junction box will be provided on the exterior of vault. Vault shall be equipped with four 12 inch by 12 inch screened vents. Vault shall be pre-fabricated of a minimum of 1/4 inch steel exterior and wood lined at least 2 inches of hardwood. Vault shall be insulated with insulation of at least R-4. Vault shall have a protective coating capable of resisting environmental elements and preventing oxidation/deterioration. Vault shall have structural stiffeners. Vault will have conduit installed to support an ADVANTOR IDS system. The contractor is responsible for coordinating these requirements with ADVANTOR Corp. This is only a partial scope of work. You must request a complete quotation package. FOB Destination: Ft. Buchanan, P.R. (necessary coordination with the Provost Marshal to deliver units on post and any coordination at the Port of San Juan is the responsiblity of the contractor). Delivery: 9 weeks after award. This is considered a commerical item and FAR clauses 52.212-1, 52.212-2, 52-212-3I, 52.212-4, 52.212-5, 52.228-5, 52.232-19, 252.212-7001 apply. Standard Industry Code (SIC) is 3484 and size standard is 500 people. Request for copies of RFQ shall be forwarded to Linda D. Stanley, datafax (334) 441-5765. Firm's physical address, telephone and facsimile numbers, and name of point of contact must be provided with request for RFQ to facilitate any overnight mailing, if required. Telephone request will not be honored. This procurement is a 100 percent set-aside for small business. See Note 1. Offers are due on 30 Aug 1999, 109 St. Joseph St., Mobile, AL, 36628-0001, Room 6000 by 4:00 p.m. All responsible sources may submit an offer which shall be considered. Posted 08/09/99 (W-SN365367). (0221)

Loren Data Corp. http://www.ld.com (SYN# 0174 19990811\13-0004.SOL)


13 - Ammunition and Explosives Index Page