COMMERCE BUSINESS DAILY ISSUE OF AUGUST 12,1999 PSA#2408U.S. Environmental Protection Agency, 75 Hawthorne St. PMD-8, San
Francisco, CA 94105-3901 J -- SERVICE CONTRACT FOR MAINTENANCE AND REPAIR OF GAS
CHROMATOGRAPHY, ETC. SOL PR-CA-99-0298 DUE 082499 POC Alvin Wong (415)
744-1023, FAX: (415) 744-1680 WEB: Service Contract for Maintenance
and Repair of Gas, A.Wong@fed.gov. E-MAIL: Wong.Alvin@epa.gov,
Wong.Alvin@epa.gov. STATEMENT OF WORK SPECIFICATIONS This Statement of
Work is for a service contract covering the items listed below. All
equipment is located at the EPA Region 9 Laboratory, 1337 South 46th
Street, Building 201, Richmond, California, 94804. One Hewlett Packard
gas chromatography/ECD system, located in Room 400, including the
following components: one model 5890E gas chromatograph (serial number
3336A59756), dual model G1223A ECD detectors (s.n. K1361 and K1362),
dual model 18593B autosampler injectors (s.n. 3524A42909 and
3524A42910), one model 18596C autosampler tray (s.n. 3524A38941), one
model G1512A autosampler control unit (s.n. 3523A02017). One
Hewlett-Packard gas chromatography/FPD system, located in Room 400,
including the following components: one model 5890A gas chromatograph
(serial number 3223A4317B), dual model 19256A flame photometric
detectors, one model 18593B autosampler injector (s.n. 3231A31681), one
model 18596B autosampler tray (s.n. 3230A29314), one model 18594B
autosampler control unit (s.n. 3231A29399). Three Hewlett Packard gas
chromatography/ECD systems, located in Room 400, including the
following components: three model 6890 gas chromatographs (model G1530,
serial numbers US00006071, US00010713, US00000648), four model G1513A
series 6890 injectors (s.n. US00002798, US00002799, US74303863,
US74303864), two model 18593B series 6890 injectors (s.n. 3514A42375,
3514A42379) three model 18596C autosampler trays (s.n. US64500124,
US74202747, 3517A38605), three model G1512A autosampler control units
(s.n. 3642A06591, US74303581, 3516A01708). One Hewlett-Packard gas
chromatography/FID/PID system, located in Room 400, including the
following components: one HP model 5890A series II gas chromatograph
(s.n. 3336A61949), one OI Analytical model 4560 sample concentrator
(s.n. J626460233), one OI Analytical model DPM-16 purging autosampler
(s.n. C642411677). One Hewlett-Packard gas chromatography/FID system,
located in Room 400, including the following components: one model
5890A gas chromatograph (s.n. 2518A05382), one model G1512A autosampler
controller unit (s.n., 3643A06735), one model G1513A autosampler
injector (s.n. US74303864), one model 18596C autosampler tray (s.n.
US64500118), One Hewlett Packard gas chromatography/mass spectrometry
system, located in Room 402, including the following components: one
model 5890E gas chromatograph (s.n. 3336A55111), one model 5972A mass
spectrometer (s.n. 3418A06135), one model 18593B autosampler injector
(s.n. 3430A39543), one model 18596B autosampler tray (s.n. 3431A36041),
one model 18594B autosampler control unit (s.n. 3429A36180), one model
59822B ionization gauge controller (s.n. 8668). Two Hewlett Packard
gas chromatography/mass spectrometry system, located in Room 203,
including the following components: 1.one HP model 5890 Series II Plus
gas chromatograph (serial number 3336A59519), one HP model 5972 Series
Mass Selective Detector (s.n. 3501A02522), one HP model 59864A Ion
Gauge Controller (s.n. 545). 2.one HP model 6890 gas chromatograph,
product number G1530A (serial number US00025948), one HP model 5973
Mass Selective Detector, product number G1099A (serial number
US82322080), one HP model G1900-60500 purge and trap concentrator
(serial number US84710883), one Varian Archon purge and trap
autosampler (serial number 12978). Two Finnigan gas chromatography/mass
spectrometry Three Hewlett Packard gas chromatography/ECD systems,
located in Room 400, including the following components: three model
6890 gas chromatographs (model G1530, serial numbers US00006071,
US00010713, US00000648), four model G1513A series 6890 injectors (s.n.
US00002798, US00002799, US74303863, US74303864), two model 18593B
series 6890 injectors (s.n. 3514A42375, 3514A42379) three model 18596C
autosampler trays (s.n. US64500124, US74202747, 3517A38605), three
model G1512A autosampler control units (s.n. 3642A06591, US74303581,
3516A01708). One Hewlett-Packard gas chromatography/FID/PID system,
located in Room 400, including the following components: one HP model
5890A series II gas chromatograph (s.n. 3336A61949), one OI Analytical
model 4560 sample concentrator (s.n. J626460233), one OI Analytical
model DPM-16 purging autosampler (s.n. C642411677). One Hewlett-Packard
gas chromatography/FID system, located in Room 400, including the
following components: one model 5890A gas chromatograph (s.n.
2518A05382), one model G1512A autosampler controller unit (s.n.,
3643A06735), one model G1513A autosampler injector (s.n. US74303864),
one model 18596C autosampler tray (s.n. US64500118), One Hewlett
Packard gas chromatography/mass spectrometry system, located in Room
402, including the following components: one model 5890E gas
chromatograph (s.n. 3336A55111), one model 5972A mass spectrometer
(s.n. 3418A06135), one model 18593B autosampler injector (s.n.
3430A39543), one model 18596B autosampler tray (s.n. 3431A36041), one
model 18594B autosampler control unit (s.n. 3429A36180), one model
59822B ionization gauge controller (s.n. 8668). Two Hewlett Packard gas
chromatography/mass spectrometry system, located in Room 203, including
the following components: 1.one HP model 5890 Series II Plus gas
chromatograph (serial number 3336A59519), one HP model 5972 Series Mass
Selective Detector (s.n. 3501A02522), one HP model 59864A Ion Gauge
Controller (s.n. 545). 2.one HP model 6890 gas chromatograph, product
number G1530A (serial number US00025948), one HP model 5973 Mass
Selective Detector, product number G1099A (serial number US82322080),
one HP model G1900-60500 purge and trap concentrator (serial number
US84710883), one Varian Archon purge and trap autosampler (serial
number 12978). Two Finnigan gas chromatography/mass spectrometryThree
Hewlett Packard gas chromatography/ECD systems, located in Room 400,
including the following components: three model 6890 gas chromatographs
(model G1530, serial numbers US00006071, US00010713, US00000648), four
model G1513A series 6890 injectors (s.n. US00002798, US00002799,
US74303863, US74303864), two model 18593B series 6890 injectors (s.n.
3514A42375, 3514A42379) three model 18596C autosampler trays (s.n.
US64500124, US74202747, 3517A38605), three model G1512A autosampler
control units (s.n. 3642A06591, US74303581, 3516A01708). One
Hewlett-Packard gas chromatography/FID/PID system, located in Room 400,
including the following components: one HP model 5890A series II gas
chromatograph (s.n. 3336A61949), one OI Analytical model 4560 sample
concentrator (s.n. J626460233), one OI Analytical model DPM-16 purging
autosampler (s.n. C642411677). One Hewlett-Packard gas
chromatography/FID system, located in Room 400, including the following
components: one model 5890A gas chromatograph (s.n. 2518A05382), one
model G1512A autosampler controller unit (s.n., 3643A06735), one model
G1513A autosampler injector (s.n. US74303864), one model 18596C
autosampler tray (s.n. US64500118), One Hewlett Packard gas
chromatography/mass spectrometry system, located in Room 402, including
the following components: one model 5890E gas chromatograph (s.n.
3336A55111), one model 5972A mass spectrometer (s.n. 3418A06135), one
model 18593B autosampler injector (s.n. 3430A39543), one model 18596B
autosampler tray (s.n. 3431A36041), one model 18594B autosampler
control unit (s.n. 3429A36180), one model 59822B ionization gauge
controller (s.n. 8668). Two Hewlett Packard gas chromatography/mass
spectrometry system, located in Room 203, including the following
components: 1.one HP model 5890 Series II Plus gas chromatograph
(serial number 3336A59519), one HP model 5972 Series Mass Selective
Detector (s.n. 3501A02522), one HP model 59864A Ion Gauge Controller
(s.n. 545). 2.one HP model 6890 gas chromatograph, product number
G1530A (serial number US00025948), one HP model 5973 Mass Selective
Detector, product number G1099A (serial number US82322080), one HP
model G1900-60500 purge and trap concentrator (serial number
US84710883), one Varian Archon purge and trap autosampler (serial
number 12978). Two Finnigan gas chromatography/mass spectrometry
systems, located in Room 201, including the following components:
1.Finnigan INCOS 50 mass spectrometer (serial number IN000377),
Hewlett/Packard model 5890A gas chromatograph (serial number
2750A18523), Tekmar ALS2016 purging autosampler, model 14-2962-200
(serial number 92196001), Tekmar LSC2000 sample concentrator, model
14-2000-000 (serial number 88239003), Tekmar sample heater accessory,
model 14-3310-500 (serial number 94098009), 2.Finnigan INCOS XL mass
spectrometer (serial number IN002547) Varian model 3400 gas
chromatograph (serial number 13886), OI Analytical model 4560 sample
concentrator (serial number J518460718), OI Analytical model DPM-16
purging autosampler (serial number C514411875), following
components:Two ABC Instruments (now OI Analytical) Gel Permeation
Chromatograpy systems, located in room 404, including the two model
AS-2000 Autoprep gel permeation chromatograph sample units (s.n.
9330-SI and 9252-SI), two model AS-2000 Autovap automated concentrator
units (s.n. 9230-AV and 9231-AV), two model UVD-1 UV-Vis detectors
(s.n. 015/13464 and 124/13183), two model 1101-9077 strip chart
recorders (s.n. 1248 and 1252). 1.PREVENTIVE MAINTENANCE INSPECTIONS
A.The Contractor will provide two (2) preventive maintenance
inspections (PMI) for all items during the contract period. PMIs will
be scheduled through communication with the Laboratory Team Leader or
designee, but should be conducted at approximately 6 month intervals.
B.PMIs will be performed in accordance with the specifications
contained in the manufacturer's service manual. 2.REPAIR SERVICE
A.Unlimited emergency service calls in the case of instrument breakdown
will be provided at no additional charge. B.The Contractor shall
operate and maintain a telephone emergency assistance number available
from 8:00 AM to 4:30 PM (Pacific time) Monday through Friday,
excluding holidays. Individuals at this number shall be capable of
providing troubleshooting information and dispatchingemergency
personnel. 3.AVAILABILITY OF TEST EQUIPMENT AND SPARE PARTS
A.Contractor will be able to show proof of order for parts replacement
within 24 hours for parts that are not included in their inventory.
The Contractor will make arrangements for the fastest delivery and will
resume work upon receipt of parts within 8 hours (one day). B.All parts
replaced will be identified by part number shown on the manufacturer's
parts list. All parts replaced will be new/exchange replacement parts
which meet the original manufacturer's specifications. C.The
Contractor will furnish all parts required in the maintenance of the
equipment listed herein at no additional cost. 4.DOCUMENTATION At the
completion of each preventive maintenance inspection and emergency
service call, the Contractor will present a written service report to
the Laboratory Team Leader or designee. This report should clearly
indicate the date of the service, the type of service performed
(emergency or preventive maintenance), the model andserial number(s) of
the equipment serviced, the name of the field service technician and a
brief description of the service performed. The Laboratory Team leader
or designee will sign the report and will receive a legible copy of the
report from the Contractor. 5.RESPONSE TIME Emergency maintenance shall
be commenced promptly after notification that equipment is inoperative
or malfunctioning and is in need of service. The Contractor shall
respond to an instrument trouble call by telephone within four (4)
hours after request for emergency service is called by authorized
supervisor at the facility. Telephone troubleshooting will be utilized
to determine the nature of the problem and to inform the facility when
the service technician will arrive. The Contractor's maintenance
personnel shall arrive at the facility within 24 hours after the
initial call-back contact. Contractor's personnel shall bring service
manuals and other information necessary to repair equipment. 6.QUALITY
OF SERVICE All Contractor Service Technicians responding to
trouble/maintenance calls where actual on-site work is to be undertaken
must have documented proof of manufacturer's maintenance training
and/or extensive experience in repair of specific equipment listed
under this contract. 7.TECHNICAL SUPPORT If the equipment listed herein
has a malfunction that remains undiagnosed after 24 hours once the
repairs have begun, then it becomes the responsibility of the
Contractor to call the manufacturer for technical support. 8.DAYS AND
HOURS OF WORK Work required in the performance of this contract shall
be performed during the Government's regular administrative working
hours, 8:00 AM to 4:30 PM, Monday through Friday, except Federal
Holidays. The Contractor will be expected to work "on-site" until the
end of the scheduled working hours period whenever necessary. The
Contractor shall notify the Laboratory Chemistry Team Leader (Richard
Bauer, 510-412-2312) or designee at least forty-eight (48) hours in
advance of all preventive maintenance visits. 9.CALL BACK SERVICE Call
back service which is required due to poor or incomplete repairs will
be available from 8:00 AM to 4:30 PM, Monday through Friday, at no
additional charge to the Government. Posted 08/10/99 (W-SN365694).
(0222) Loren Data Corp. http://www.ld.com (SYN# 0072 19990812\J-0034.SOL)