COMMERCE BUSINESS DAILY ISSUE OF AUGUST 16,1999 PSA#2410Marine Corps Regional Contracting Office, Northeast Region, 2010
Henderson Road, Marine Corps Base, Quantico, Virginia 22134-5045 63 -- SECUIRTY SYSTEM SOL M00264-99-T-0052 DUE 082799 POC Virginia
Armstrong, Contract Specialist, (703)784-1928 FAX (703)784-5908 This is
a combined synopsis/soliciation for commercial items prepared in
accordance with the format in FAR subpart 12.6, as supplemented with
additional information included in this notice. This announcement
constitutes the only soliciation; proposals are being requested and a
written solicitation will not be issued. The solicitation document and
incorporated provisions and clauses are those in effect through the
Federal Acquisition Circular 97-12. The Marine Corps Northeast Regional
Contracting office currently has a requirement for furnishing and
installing a Facility Security System Hardware/Software package located
at the Battle Staff Training Facility, 2048 South Street, MCCDC,
Quantico, VA. to include: a. Computer System with Uninterrupted Power
Source (UPS), applicable programs, back-up hard drive capable of
supporting an automated security system of at least 100 zones. b.
Associated documentation and back-up must be provided. c. Capability of
expanding system to include an additional 100 zones.d. Instruction on
all systems installed, and basic trouble shooting. e. Capability of
knowing which doors are open and clsoed at any given time. f. The
capability to make badge/pass-cards on site. g. Capability to make
badge/pass-cards off site. h. Capability of creating limited access for
each zone within the facility. i. Capability to make self expiring
badges/pass-cards. j. Capability of setting times of allowed access. k.
Maintain the Visual integrity of the facility. l. Wiring must be behind
walls. m. Modifying existing security doors and installing electric
strike devices. n. Modifying existing security doors and installing
electric door bottoms. o. Installing security bars on existing windows
x7. p. Installing magnetic locks on existing doors, including 2 sets
of double loading doors. q. Replace 13 existing storage locks (keyted
entry only) with classroom locks (optional entry, with or without key).
r. Replace existing fire doors with approved security doors. s. Install
emergency exit/CDX07 locks on replacement fire doors. t. Install
"open/shut" sensors on existing and replacement doors. u. Install 2X
keyed access locks on existing doors (key required for both
directions). v. Central location of the system will be on the (1st)
first floor, within the administration office. w. Rehang all doors to
shut properly. x. Place wrap around astragal's on all double doors x6.
y. Plane door edge's to ensure proper fit. z. 90 day warranty. A
written request for quotation will not be issued. Award will be made by
delivery date, item or lot whichever is most advantageous to the
Government. All contractors msut be reqistered in the Central
Registration (CCR). Address is: www.ccr.edi.disa.mil. Quotes shall be
returned to the office address listed above, by mail or faxed by the
close of business on 27 Jul 99. SITE VISIT VAR 52.237-1 (APR 1984:)
OFFERORS ARE URGED AND EXPECTED TO INSPECT THE SITE WHERE SERVICES ARE
TO BE PERFORMED AND TO SATISFY THEMSELVES REGARDING ALL GENERAL AND
LOCAL CONDITIONS THAT MAY AFFECT THE COST OF CONTRACT PERFORMANCE TO
THE EXTENT THAT THE INFORMATION IS REASONALBE OBTAINABLE. IN NO EVENT
SHALL FAILURE TO INSPECT THE SITE CONSTITUTE GROUNDS FOR A CLAIM AFTER
CONTRACT AWARD. ARRANGEMENTS FOR SITE INSPECTION SHALL BE MADE BY
CONTACTING THE FOLLOWING DURING THE HOURS OF 9:00 AM TO 3:00 PM MONDAY
THROUGH FRIDAY EXCLUDING HOLIDAYS. ACTIVITY: PURCHASING AND
CONTRACTING BRANCH NAME: VIRGINIA ARMSTRONG TELEPHONE: (703) 784-1928
See Note(s) 1 Posted 08/12/99 (W-SN366908). (0224) Loren Data Corp. http://www.ld.com (SYN# 0387 19990816\63-0003.SOL)
63 - Alarm, Signal and Security Detection Systems Index Page
|
|