COMMERCE BUSINESS DAILY ISSUE OF AUGUST 16,1999 PSA#2410Northern Division, NAVFACENGCOM, 10 Industrial Highway, Mail Stop #82,
Lester, PA 19113-2090 Y -- DESIGN/BUILD FOR UPGRADE OF CHILLED WATER SYSTEM AND
ENVIRONMENTAL MONITORING, DEFENSE MEGA CENTER, OGDEN HILL AIR FORCE
BASE, UTAH SOL N62472-99-R-0030 DUE 100199 POC Irene Katacinski,
Contract Specialist, 610-595-0628. This is a Modification to update the
following information in the CBD issue of July 30, 1999 PSA#2399 Posted
07/28/99 (I-SN359949). (0209) (SYN# 0168 19990730 Y-0020.SOL) This is
a Procurement Notice. This acquisition is being conducted using full
and open competition (Unrestricted) and is therefore subject to the
Federal Acquisition Regulation Clause 52.219-4 "Notice of Price
Evaluation Preference for Hubzone Small Business Concerns". The
contract will provide for the Design/Build for Upgrade of Chilled Water
System and Environmental Monitoring System, Defense Mega Center (DMC),
Ogden, Hill Air Force Base, Utah. The Department of Navy (DON) intends
to issue a Request for Proposals (RFP) for the Design/Build for Upgrade
of Chilled Water System and Environmental Monitoring System at the DMC,
Ogden, UT utilizing a two-phase design-build selection process based on
best value to the Government. Phase-One evaluation will be based on the
following factors of equal importance: 1)Past Performance,
2)ManagementApproach, 3)Technical Experience, Expertise, and
Qualifications, and 4) Commitment to Small Business Concerns. Offerors
will be required to provide information for both their construction
team, as well as their design team under these factors. Based on its
evaluation of the Phase-One, the DON will invite up to five (5)
Offerors judged best qualified for the HVAC project at DMC, Ogen, UT to
participate in Phase-Two. Phase-Two will consist of Price and Technical
proposals which are approximately equal in importance. The HVAC work
includes the removal of two 400 ton chillers, removal of one 105 ton
chiller, provide three 500 ton chillers (The option for the chiller has
been removed), remove the three companion cooling towers and provide
three 500 ton cooling towers (The option for the tower has been
removed). Provide an additional (redundant) chilled water piping loop,
remove existing chilled water pumps and provide chilled water pumps
and primary/secondary pumping system including variable speed drives,
Provide humidification units and modifications to computer room
air-conditioning unit flow chilled water flow control valves. The
contractor shall design, engineer and construct a replacement and
installation, including all parts and equipment of the facility's total
Mechanical Chilled water system and HVAC control work including
converting the existing controls and Sentinel monitoring system and
provide HVAC controls utilizing Genesis by Iconis software for
monitoring and control. All work will be accomplished in an active
computer center and attendant office area. During construction the
cooling for the building must be maintained on a 24 hour a day, seven
day per week basis during construction. Estimated cost range for this
project is between $1.5 -- $3.0 million dollars. Estimated contract
award date is February 2000. The SIC Code is 1711 and the size standard
is $7.0 million are applicable to this contract. The solicitation will
be issued as Unrestricted. The Government intends to issue this
Request for Proposals for Phase-One on or about 1 September 1999 and
the date for receipt of Phase-One proposals is on or about 30 days
later at 2:00 p.m., at Northern Division, Naval Facilities Engineering
Command, 10 Industrial Highway, Mail Stop #82, Lester, PA 19113-2090.
In accordance with FAR 5.102(a)(7), availability of the solicitation
will be limited to the electronic medium. Plans and Specifications will
NOT be directly provided in a paper hard copy format or CD ROM. The
address for downloading this solicitation from the Internet is:
http://www.efdnorth.navfac.navy.mil/code02.html. Downloading from the
Internet is free of charge, however, some plans and specifications will
take a considerable amount of time to download. All prospective
offerors are encouraged to register on the Northern Division Internet
ebs web site for this project when plans and specifications become
available. Official Planholders will be maintained on and can be
printed from the website. Planholders lists will not be faxed and will
only be available from the website. Contractors interested in
obtaining notification when the Request for Proposal package is
electronically posted on the Internet may fax to Ms Sheila Brown at
(610) 595-0644 on your company letterhead the following information:
Solicitation Number and Title of Project, Complete Address, Point of
Contact, Area code and phone number, Area code and fax number, E-mail
address, identify whether the firm is a prime contractor,
sub-contractor or supplier, indicate whether the firm is a small
business, small disadvantaged business, large business and if the firm
is a women owned business. Recording companies and Blueprint companies
are also required to forward their information via fax. Notification of
any changes to this solicitation (amendments) shall be made only on the
Internet. It is therefore the contractor's responsibility to check the
internet site listed below daily for any posted changes to the
solicitations plans and specifications. Per the Debt Collections
Improvement Act of 1996,the Defense Federal Acquisition Regulation
Supplement (DFAR) has been amended to require all contractors to
register in the Department of Defense (DOD) Central Contractor
Registration (CCR) Database. Be advised for solicitations issued after
May 31, 1998, failure to register in the CCR makes an offeror
ineligible for award of DOD contracts. Information regarding this
registration may be obtained by accessing our website at
http:/www.efdnorth.navfac.navy.mil. or by referring to DFARS Subpart
204.703. Offerors should submit vertification of their firm's
registration in the CCR Database with their proposal. (Many firms and
commercial printing services have the capability to print the RFP and
planholders list off the internet) This is a pre-solicitation notice
only. Exact RFP issuance and closing dates, as well as the date and
location of the pre-proposal conference, will be set forth prior to
release of the RFP. FAX technical questions concerning this project to
Irene Katacinski at (610) 595-0644. Posted 08/12/99 (I-SN367133).
(0224) Loren Data Corp. http://www.ld.com (SYN# 0141 19990816\Y-0013.SOL)
Y - Construction of Structures and Facilities Index Page
|
|