Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF AUGUST 19,1999 PSA#2413

Arnold Engineering Development Center, Attn: AEDC PKP, 100 Kindel Drive, Suite A332, Arnold AFB TN 37389-1332

66 -- PHOTOACOUSTIC MULTI-GAS MONITOR SOL F40650-99-Q-0015 POC Tony Clayborne, Contracting Officer, (931) 454-3918 WEB: click here to download a copy of the RFQ, pixs.wpafb.af.mil/arnold.asp. E-MAIL: click here to contact the contracting officer via, Tony.Clayborne@arnold.af.mil. This requirement is for a photoacoustic infra-red spectroscopic instrument, capable of quantitiative analysis of up to 5 components and water in gas mixtures with the following specifications: optical filters must be included to detect the following compounds: Total hydrocarbons, trichloroethylene, ethylene glycol and propylene glycol; automatic compensation for temperature fluctuations, water-vapor interference and interference from other known gases; response times for one gas as low as 13 seconds, response times for 5 gases and water as low as 40 seconds; multiple user-selected sample integration times; 5 orders of magnitude dynamic range; measurement units of mg/m3, g/m3, ug/m3, ppm, vol %, and ppb; zero drift (measured at 100 times the detection limit): + or -- the detection limit per 3 month period, + or -- 10% of the detection limit per degree C, + or -- 0.5% of the detection limit per mbar; repeatability: 1% of the measured value; Range drift: + or -- 2.5% of measured value per 3 months, + or -- 0.3% of measured value per degree C, + or -- 0.01% of measured value per mbar; for stand-alone operation: data storage sufficient for a 12-day monitoring episode at 10 minute intervals for 5 gases and water vapor; Portable: must weigh less than 25 lbs; no warm-up time required; display up to 6 gas concentration graphs; uses ODBC; Power requirements: 100-127 VAC and 200-240 VAC; Power consumption: approximately 100 VA; battery backup to protect stored data and internal clock; Acoustic sensitivity: not influenced by external sound; Communication: IEEE 488 and RS-232 interface for data exchange and remote control of the unit. The performance period shall be 30 calendar days after contractor receipt of written notification of contract award. Any responsible small business source may submit a quote which shall be considered. Firms responding to this synopsis should indicate whether or not they are a minority business concern. Foreign participation is authorized. Quotes will be due 10 calendar days after issuance of the Request for Quote. The anticipated due date is estimated to be 10 September 1999. "See Note 1". Posted 08/17/99 (W-SN368675). (0229)

Loren Data Corp. http://www.ld.com (SYN# 0391 19990819\66-0011.SOL)


66 - Instruments and Laboratory Equipment Index Page