|
COMMERCE BUSINESS DAILY ISSUE OF AUGUST 27,1999 PSA#2420National Park Service, 600 Harrison Street, Suite 600, San Francisco,
CA 94107-1372 55 -- MODIFICATION TO REQUIREMENT FOR REDWOOD POSTS SOL RQ8000-99-027
DUE 091099 POC Theresa Fisher 415/427-1331 E-MAIL: Click here to
contact the contracting officer via, theresa_fisher@nps.gov. This
amends a previously published combined synopsis/solicitation for
Redwood posts to be delivered FOB to Manzanar National Historic Site.
This amendment adds additional requirements to the following sections
of the synopsis/solicitation: 1) SPECIFICATIONS FOR REDWOOD, 2)
REQUIREMENTS FOR PACKAGING REDWOOD FOR SHIPPING, and 3) DELIVERY AND
UNLOADING ON SITE. All other terms and provisions remain the same.
Accordingly, the above three sections of the synopsis/solicitation are
deleted in their entirety and replaced with the following:
SPECIFICATIONS FOR REDWOOD: All Redwood shall be coastal redwood of the
Sequoia sempervirens species. All Redwood shall be endorsed by the
Forest Stewardship Council (FSC). All Redwood shall meet or exceed the
grade requirements for Construction Heart grade as described in the
latest edition of the Standard Specifications for Grades of California
Redwood Lumber. All Redwood shall be Free of Heart Center (FOHC). All
Redwood shall be rough sawn to the full dimension specified if
available. If full dimension is not available, then it is to be as full
sawn as available. All Redwood posts shall have both ends cut squarely.
As soon as possible after cutting, ends of redwood posts shall be
sealed with Anchor Seal, or approved equal, to control moisture loss
and prevent warping and checking. Only the ends of posts shall be
coated with sealer. The redwood posts are to be used in the
rehabilitation of an historic fence and will be installed rough sawn as
they arrive from the mill, without any further milling or planing. Care
must be taken in applying the sealer so that no sealer is applied to
the sides of the posts. After cutting, all Redwood is to be sticker
stacked as noted below to prevent warping and twisting. There are no
requirements for moisture content. REQUIREMENTS FOR PACKAGING REDWOOD
FOR SHIPPING: Redwood posts are to be shipped in sticker stacked
bundles not to exceed 1500 pounds in weight. To prevent infection of
Redwood, sticker lath shall be free of stain and decay and have a
moisture content of less than 20%. Bundles shall be constructed to
allow handling by a forklift and storage on level ground. Redwood posts
shall be stacked in layers with 1x2 or 1x3 sticker lath of a uniform
thickness separating each layer of posts. Posts on each layer shall be
laid tightly against each other, and shall also be aligned vertically.
Stickers shall be placed approximately 12" from the ends of posts and
spaced uniformly, with a maximum of 24" between stickers. Bundles of
sticker stacked posts shall be banded with flat metal straps aligned
with the stickers. The metal straps shall be tight and flat against the
redwood to prevent shifting during shipping and warping or twisting
during seasoning. Redwood shall be protected from crushing by the metal
straps, including the use of suitable protection at corners. DELIVERY
AND UNLOADING ON SITE: Redwood shall be delivered to the Auditorium
area of Manzanar National Historic Site (the Park) which is located on
the west side of US Highway 395 approximately 5 miles south of
Independence, California. Contractor must coordinate delivery with the
Park Superintendent, Ross Hopkins, at least two weeks prior to the
actual delivery date. Telephone Number at the Park office is (760)
878-2932, or (760) 878-2031. Redwood shall be delivered FOB destination
during the month of October 1999. Redwood bundles shall be placed in a
location near auditorium, as designated by the Park Superintendent.
Contractor shall provide all equipment and supplies, including a
forklift, to off-load and stack Redwood at the delivery site. Redwood
bundles shall be shimmed to level on the site to prevent shifting or
warping during seasoning. Stacked bundles shall be aligned vertically
and horizontally with supporting bundles and shall have a minimum air
space of 6" between the ground and stacked Redwood. Posted 08/25/99
(W-SN372531). (0237) Loren Data Corp. http://www.ld.com (SYN# 0305 19990827\55-0001.SOL)
55 - Lumber, Millwork, Plywood and Veneer Index Page
|
|