Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF AUGUST 27,1999 PSA#2420

HQ, INDUSTRIAL OPERATIONS COMMAND, ATTN AMSIO-ACI, BLDG 350 5TH FLOOR MIDDLE BAY, ROCK ISLAND IL 61299-6000

99 -- IACEM 980 CONTINUOUS MONITORING SYSTEM SOL DAAA09-99-R-2092 DUE 091599 POC Contract Specialist Ms. Chris Tindle (309) 782-3449, FAX (309)782-4955 (Site Code DAAA09) E-MAIL: TINDLEC@IOC.ARMY.MIL, TINDLEC@IOC.ARMY.MIL. This solicitation is 100% Set-aside for Small Business.6 This is a combined CBD Synopsis/Solicitation Package. The Solicitation Number is DAAA09-99-R-2092 and should be referenced on any and all documents. PROPOSALS ARE DUE NOT LATER THAN 1400 CDT 15 SEP 99. This is a firm fixed price requirement for 9 Each, Part Number FA-01-0776PBA, IACEM 980 Continuous Monitoring System. The upgrade proposed is a replacement part for the existing Real Time Analytical Platforms (RTAPs) at Pine Bluff Chemical Activity, Pine Bluff Arsenal, Pine Bluff Arkansas. RTAPs are mobile monitoring systems designed by the Army for detecting low levels of chemical agents. The instrumentation includes, in part, a monitoring system composed of a Dynatherm ACEM 900 sampler mounted on a Hewlett Packard gas chromatograph. An improved Dynatherm unit is now available called IACEM 980 as a replacement for the older ACEM 900. The new unit must be a direct replacement part for the existing monitoring system. The specifications for the replacement part are as follows: It will have dual collection tubes operating in alternate cycles to provide continuous, uninterrupted sample collection and concentration throughout the survey period. Each is linked in tandem with a focusing trap, enabling efficient chromatographic separation of agents and interferences. It will be fully automated and have the same Heated Zones, Setpoint Range, Timed Events, Sampling Flow, RS-232 Interface, GC Interface, Carrier Gas/Valving, Environment, Power Requirements and Dimensions as the original commercially available ACEM 900 it is replacing. The required delivery date is 30 Nov 99. Delivery is F.O.B. destination. Delivery shall be made to: Transportation Officer, M/F Property Office, Receiving Station, RSI Branch, Building 23-330,Pine Bluff Arsenal, Pine Bluff, AR 71602-9500. In Accordance with Clause 52.212-2, Technical evaluation will be performed on the above stated requirements. Technical will be pass/fail. Price and past performance will also be evaluated with price being more important than past performance. Offerors are required to submit verification of the above technical information with their offers. Offerors are required to submit at least three references for past performance evaluation. The offeror shall submit the reference company name, address, phone number, fax number and point of contact. References may be commercial or state, local or federal government. NOTE: Contractors must have a cage code and must be registered in the CCR to be eligible for award. The following FAR, DFARS and Local clauses are applicable to this solicitation. 52.252-1 Solicitation Provisions Incorporated by Reference; 52.252-2 Clauses Incorporated by Reference; 52.247-34 FOB Destination; 52.211-15 Defense Priority and Allocation Requirements; 52.212-1 Instructions to Offerors Commercial Items; 52.212-4 Contract Terms and Conditions Commercial Items; 52.000-4032 Restrictions on Use of Toxic Release Inventory Chemicals; 52.000-4148 Commercial Packaging, Packing and Marking Instructions; 52.232-4503 (52.000-4230) Remittance Address; 52.212-3III (52.000-4630) Offeror Representations and Certifications Commercial Items; 52.212-5 (52.0000-4650) Contract Terms and Conditions Required to implement Statutes or Executive Orders Commercial Items; 52.212-7000 (52.000-4660) Offeror Representations and Certifications Commercial Items; 252.247-7023 Notification of Transportation of supplies by Sea; 252.212-7001 (52.000-4671) Contract Terms and Conditions Required to Implement Statutes or Executive Orders Applicable to Defense Acquisitions of Commercial Items; 52.000-4834 AMC-Level Protest Program; 52.239-4500 (52.000-4911) Requirement for Information Technology to Be Year 2000 Compliant; 52.000-4915 Media Contacts; 252.204-7004 Required Central Contractor Registration; 52.211-14 Notice of Priority Rating for National Defense Use; 52.212-2 Evaluation Commercial Items; 52.215-5 FACSIMILE Proposals; 252.225-7035 Buy American Act -- North American Fee Trade Agreement Implementation Act -- Balance ofPayments Program Certificate; 52.204-6 Data Universal Numbering System (DUNS) Number; 52.0219-0006 "Notice of Total Small Business Set-Aside"; NOTE: THE FOLLOWING CLAUSES LISTED ABOVE HAVE A REQUIREMENT FOR CONTRACTOR TO FILL IN THE BLANKS. THIS SHALL BE ACCOMPLISHED AND RETURNED IN HARD COPY: 52.232-4503(52.000-4230); 52.212-3III(52.000-4630); 52.212-7000 (52.000-4660); 252.225-7035. ALSO PLEASE TAKE NOTE OF THE REQUIREMENT IN CLAUSE 52.204-6. Posted 08/25/99 (A-SN372508). (0237)

Loren Data Corp. http://www.ld.com (SYN# 0404 19990827\99-0009.SOL)


99 - Miscellaneous Index Page