COMMERCE BUSINESS DAILY ISSUE OF AUGUST 27,1999 PSA#2420HQ, INDUSTRIAL OPERATIONS COMMAND, ATTN AMSIO-ACI, BLDG 350 5TH FLOOR
MIDDLE BAY, ROCK ISLAND IL 61299-6000 99 -- IACEM 980 CONTINUOUS MONITORING SYSTEM SOL DAAA09-99-R-2092 DUE
091599 POC Contract Specialist Ms. Chris Tindle (309) 782-3449, FAX
(309)782-4955 (Site Code DAAA09) E-MAIL: TINDLEC@IOC.ARMY.MIL,
TINDLEC@IOC.ARMY.MIL. This solicitation is 100% Set-aside for Small
Business.6 This is a combined CBD Synopsis/Solicitation Package. The
Solicitation Number is DAAA09-99-R-2092 and should be referenced on any
and all documents. PROPOSALS ARE DUE NOT LATER THAN 1400 CDT 15 SEP 99.
This is a firm fixed price requirement for 9 Each, Part Number
FA-01-0776PBA, IACEM 980 Continuous Monitoring System. The upgrade
proposed is a replacement part for the existing Real Time Analytical
Platforms (RTAPs) at Pine Bluff Chemical Activity, Pine Bluff Arsenal,
Pine Bluff Arkansas. RTAPs are mobile monitoring systems designed by
the Army for detecting low levels of chemical agents. The
instrumentation includes, in part, a monitoring system composed of a
Dynatherm ACEM 900 sampler mounted on a Hewlett Packard gas
chromatograph. An improved Dynatherm unit is now available called IACEM
980 as a replacement for the older ACEM 900. The new unit must be a
direct replacement part for the existing monitoring system. The
specifications for the replacement part are as follows: It will have
dual collection tubes operating in alternate cycles to provide
continuous, uninterrupted sample collection and concentration
throughout the survey period. Each is linked in tandem with a focusing
trap, enabling efficient chromatographic separation of agents and
interferences. It will be fully automated and have the same Heated
Zones, Setpoint Range, Timed Events, Sampling Flow, RS-232 Interface,
GC Interface, Carrier Gas/Valving, Environment, Power Requirements and
Dimensions as the original commercially available ACEM 900 it is
replacing. The required delivery date is 30 Nov 99. Delivery is F.O.B.
destination. Delivery shall be made to: Transportation Officer, M/F
Property Office, Receiving Station, RSI Branch, Building 23-330,Pine
Bluff Arsenal, Pine Bluff, AR 71602-9500. In Accordance with Clause
52.212-2, Technical evaluation will be performed on the above stated
requirements. Technical will be pass/fail. Price and past performance
will also be evaluated with price being more important than past
performance. Offerors are required to submit verification of the above
technical information with their offers. Offerors are required to
submit at least three references for past performance evaluation. The
offeror shall submit the reference company name, address, phone number,
fax number and point of contact. References may be commercial or state,
local or federal government. NOTE: Contractors must have a cage code
and must be registered in the CCR to be eligible for award. The
following FAR, DFARS and Local clauses are applicable to this
solicitation. 52.252-1 Solicitation Provisions Incorporated by
Reference; 52.252-2 Clauses Incorporated by Reference; 52.247-34 FOB
Destination; 52.211-15 Defense Priority and Allocation Requirements;
52.212-1 Instructions to Offerors Commercial Items; 52.212-4 Contract
Terms and Conditions Commercial Items; 52.000-4032 Restrictions on Use
of Toxic Release Inventory Chemicals; 52.000-4148 Commercial
Packaging, Packing and Marking Instructions; 52.232-4503 (52.000-4230)
Remittance Address; 52.212-3III (52.000-4630) Offeror Representations
and Certifications Commercial Items; 52.212-5 (52.0000-4650) Contract
Terms and Conditions Required to implement Statutes or Executive
Orders Commercial Items; 52.212-7000 (52.000-4660) Offeror
Representations and Certifications Commercial Items; 252.247-7023
Notification of Transportation of supplies by Sea; 252.212-7001
(52.000-4671) Contract Terms and Conditions Required to Implement
Statutes or Executive Orders Applicable to Defense Acquisitions of
Commercial Items; 52.000-4834 AMC-Level Protest Program; 52.239-4500
(52.000-4911) Requirement for Information Technology to Be Year 2000
Compliant; 52.000-4915 Media Contacts; 252.204-7004 Required Central
Contractor Registration; 52.211-14 Notice of Priority Rating for
National Defense Use; 52.212-2 Evaluation Commercial Items; 52.215-5
FACSIMILE Proposals; 252.225-7035 Buy American Act -- North American
Fee Trade Agreement Implementation Act -- Balance ofPayments Program
Certificate; 52.204-6 Data Universal Numbering System (DUNS) Number;
52.0219-0006 "Notice of Total Small Business Set-Aside"; NOTE: THE
FOLLOWING CLAUSES LISTED ABOVE HAVE A REQUIREMENT FOR CONTRACTOR TO
FILL IN THE BLANKS. THIS SHALL BE ACCOMPLISHED AND RETURNED IN HARD
COPY: 52.232-4503(52.000-4230); 52.212-3III(52.000-4630); 52.212-7000
(52.000-4660); 252.225-7035. ALSO PLEASE TAKE NOTE OF THE REQUIREMENT
IN CLAUSE 52.204-6. Posted 08/25/99 (A-SN372508). (0237) Loren Data Corp. http://www.ld.com (SYN# 0404 19990827\99-0009.SOL)