COMMERCE BUSINESS DAILY ISSUE OF AUGUST 31,1999 PSA#2422National Cancer Institute, Research Contracts Branch, PSAS, 6120
Executive Blvd, EPS/Room 638, Bethesda, MD 20892-7227 66 -- 2K X 2K MEGASCAN GRADE 2 SOL NCI-RFQ-90212-NR DUE 091319 POC
Marsha Gorham, Purchasing Agent & Todd Cole, Contracting Officer The
National Cancer Institute, Division of Clinical Sciences, Laboratory of
Biochemistry plans on procuring two 2k x 2k CCD cameras to be included
on two FEI Tecnai 30 microscopes which were recently purchased from
FEI Company, 7310 Grove Road, Frederick,MD 21704. NCI has established
an electron microscopy facility that will be used for 1) structural
determination of membrane proteins and membrane protein complexes at
atomic resolution and 2) structural determination of macromolecular
assemblies from single particle imaging studies. The cornerstone of the
facility is a state-of-the-art Tecnai 30 electron microscope that was
purchased under a previous competitive procurement. The Laboratory of
Biochemistry now has a requirement to include a Gatan 794 Megascan
camera/capturer ( the camera shall possess <400kV/YAG/B/2k) for the
microscope's wide angle camera port and for below the projection
chamber either on axis or off-axis. The CCD system shall be integrated
internally into the Tecnai 30 Twin microscopes to create a seamless
integration of controls for microscope operation and CCD image
acquisition. Thus, only one graphical user interface, computer monitor,
and keyboard shall be utilized for both the CCD camera and the
microscopes to reduce error and increase efficiency in more complex
analyses. In addition, the camera shall be factory installed to insure
that all existing warranties remain intact and undisputed on the
Tecnai 30 electron microscope. FEI Company is the only source known to
the NCI researcher that can meet the above requirement, especially
with regard to maintaining a seamless integration with the Tecnai 30
and maintaining the warranties on the microscope. If any interested
party believes it can meet the above requirement, it may submit a
statement of capabilities. The statement of capabilities and any other
information furnished must be in writing and must contain material in
sufficient detail to allow NCI to determine if the party can perform
this requirement. Capability statements must be received in the
contracting office by 3:00 p.m. EST, on September 13, 1999. If you have
any questions, please contact Marsha Gorham, Purchasing Agent on (301)
402-4509. A determination by the Government not to compete this
proposed requirement based upon responses to this notice is solely
within the discretion of the Government. Information received will be
considered solely for the purpose of determining whether to conduct a
competitive procurement. Posted 08/27/99 (W-SN373439). (0239) Loren Data Corp. http://www.ld.com (SYN# 0374 19990831\66-0002.SOL)