Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF SEPTEMBER 1,1999 PSA#2423

Fleet & Industrial Supply Center, Regional Contracts Dept, Attn: Bid Officer/Code 210A94, 937 N. Harbor Drive, Suite 212, San Diego, CA 92132-0212

46 -- DELIVERY OF DE-IONIZED WATER SOL N00244-99-T-0907 DUE 090999 POC Contracting Officer @619-532-2588; FAX 619-532-2347 WEB: click here to obtain other FISC requirements., http://www.sd.fisc.navy.mil. This amendment is adding more information to submission #359677, submitted on 7-27-99. The following information is being added to supplement the first CBD announcement. The closing date of this announce is being extended to 9-9-99. All other items remain the same. Clin 0001 -- bldg. 788 (clin 0001, 0004, 0007, 0010, 0013) Maintenance for deionized water in tanks: make up tanks to provide 1000 gallons of water per week. 1 each -- 1.5 cu. Ft. two bed deionizer 2 each -- 2.5 cu. Ft. mixed deionizers 2 each -- 20" 5 micron pre-filters (2 filters per month) RO UV sterilizer 2 each -- 20" .2 micron final filter (4 filters changed every 3 months) clin 0002, 0005, 0008, 0011, 0014) Clin 0002 -- 2.5 cu. Ft. resin beds (4 each) to be replaced within 2 -- 3 days every 3 -- 4 months. They require as many as six exchanges depending on workload. No USN medical tank. The lamp is a Sterlight ultra violet. Ultra violet water sterilizer bulb, r-can, module 536RL. The carbon and charcoal filters are replaced every few months, depending on the workload. POC David Williams; 619-553-3044 (clin 0003, 0006, 0009, 0012, 0015) Clin 0003 -- Contractor shall provide rental of twelve (12) deionized water tanks to maintain a support water make-up to main tank. Eight tanks are being on-line and the remaining four are to be on emergency stand-by. The contractor shall provide all twelve tanks upon start date. The tanks consist of three (3) Cstion tanks, three (3) Anion tanks, three (3) mixed bed tanks, and three (3) Chloramine carbon filter tanks. Three (3) tanks shall have the capacity of maintaining forty thousand gallons of water without the necessity of regeneration of one-month run-time while on primary system. The water entering these tanks is 98% free of all sodium ions from the reverse osmosis system. The purity of water coming from this system allows the contractor's bottles to last up to the specified requirement. Upon arrival at the Naval Hospital, prior to exchanging bottles, the contractor shall contact PWC at bldg. 8 across from the main deionized water tank system. The primary person to contact is Wayne Morris (619-532-8716). When Mr. Morris is unavailable, the contractor shall contact any supervisor of PWC employees located at bldg. 8. The contractor shall then replace exhausted primary system bottles with secondary system bottles and place new regenerated bottles which meets original spec.'s on secondary system. The contractor shall then take exhausted bottles to be regenerated, which will then be brought back to PWC. This process shall be repeated every month until the end of the contract agreement. The following specifications shall be on the chloramine carbon filter. Chloramine carbon filter containing virgin material consistent with hemodialysis water purification requirements. The contractor shall provide all material needing to keep primary and secondary bottles on line. The primary and secondary system having a 200,000-ohm indicating light and the mixed bed having one mega ohm indicating light. The contractor shall be responsible for maintaining the indicating lights, all fittings and hoses connected to the bottles provided by the contractor. The existing system can be easily modified by the contractor to fit the contractor's bottles. The inlet is " fpt PVC and the outlet is " fpt PVC. If necessary, for down time, the contractor shall notify PWC prior to making any changes to the existing fittings. PWC keeps records of water meter readings daily. The contractor shall also keep records of water meter readings when exchanging exhausted bottles. The contractor shall respond within four-hours upon notification of a problem. The correction shall be made within 24 hours of notification or contract could be cancelled for non-compliance. The contractor shall provide services to replenish and regenerate eight (8) 3.3 cubic feet per tank with type 1 Anion mixed bed semi conductor nuclear grade resin, to maintain 18 megohms water quality. This shall be performed throughout the contract terms upon PWC request as an inclusive to the contract agreement. This should be done in a timely manner which is within 5 working days. The contractor shall provide labor and material to replace eight (8) ultraviolet sterilizer lamps, type aquafine part number 3084 UV lamps. Initial changes are required one month after contract start date. The contractor shall replace the lamps during the term of the contract at no charge if lamps' longevity is below eight thousand working hours. Lamp replacement shall be done in a timely manner which is within 5 working days. PWC point of contact, Mr. Morris or a PWC supervisor shall be notified prior to lamp replacement. As for building 14 Navy Hospital core school, rental service of four mixed bed deionization tanks; two tanks shall be replaced every month. The two primary tanks shall be replaced with the two secondary tanks and the secondary tanks shall be replaced with the two new regenerated tanks. The two exhausted primary tanks shall be taken back for regeneration. The contractor shall comply with all spec. as stated above. Posted 08/30/99 (W-SN374206). (0242)

Loren Data Corp. http://www.ld.com (SYN# 0258 19990901\46-0004.SOL)


46 - Water Purification and Sewage Treatment Equipment Index Page