COMMERCE BUSINESS DAILY ISSUE OF SEPTEMBER 8,1999 PSA#2427Fleet & Industrial Supply Center, Regional Contracts Dept, Attn: Bid
Officer/Code 210A94, 937 N. Harbor Drive, Suite 212, San Diego, CA
92132-0212 49 -- PNEUMATIC TEST STAND SOL N00244-99-T-B129 DUE 090799 POC
Catherine McCollum, Phone (619) 532-2886; FAX (619) 532-2575 WEB: Click
here to obtain more information about FISC San,
http://www.sd.fisc.navy.mil. E-MAIL: Click here to contact the
Contracts Specialist via, catherine_i_mccollum@sd.fisc.navy.mil. The
following questions have been asked by industry regarding this
procurement. The Government's answers immediately follow the question.
(1Q): The L.P. system has one pressure regulator and six outlet
pressure gauges. Are shutoff valves required upstream of each of the
gauges? (1A): No. (2Q): The H.P. system has one pressure regulator and
five outlet pressure gauges. Are shutoff valves required upstream of
these gauges? (2A): No. Posted 09/03/99 (W-SN376428). (0246) Loren Data Corp. http://www.ld.com (SYN# 0221 19990908\49-0001.SOL)