COMMERCE BUSINESS DAILY ISSUE OF SEPTEMBER 14,1999 PSA#2431U. S. Environmental Protection Agency, Contracts Management Division
(MD-33), Attention: OARSC, Research Triangle Park, NC 27711 61 -- AC GENERATOR; EPA CERTIFIED, TRAILER MOUNTED, DIESEL FUELED SOL
EEE497 DUE 092799 POC Joel P. Smith, Contract Specialist, (919)
541-0184/Kathy Moore, Contracting Officer, (919) 541-0184 E-MAIL:
"Click" here to contact the Contract Specialist via,
smith.joel@epa.gov. 17. THIS IS A COMBINED SYNOPSIS/SOLICITATION FOR
COMMERCIAL ITEMS PREPARED IN ACCORDANCE WITH THE FORMAT IN SUBPART
12.6, AS SUPPLEMENTED WITH ADDITIONAL INFORMATION INCLUDED IN THIS
NOTICE. THIS ANNOUNCEMENT CONSTITUTES THE ONLY SOLICITATION; QUOTES ARE
BEING REQUESTED AND A WRITTEN SOLICITATION WILL NOT BE ISSUED. The
solicitation number is EEE497 and the solicitation is being issued as
a Request for Quote solicitation document and incorporated provisions
and clauses are those in effect through Federal Acquisition Circular
97-10. The Environmental Protection Agency (EPA) anticipates that the
contract will be awarded as a result of full and open competition. A
firm-fixed-price purchase order is anticipated to result from the award
of this solicitation. The associated Standard Industrial Code (SIC) is
3621. This procurement is for acquisition of a Trailer Mounted,
Environmental Protection Agency (EPA) certified, Diesel Fueled Engine
Driven AC Generator. The following specifications apply: General
Specifications: 20 kW prime output 120/240 VAC 60 Hz 1 4 wire
generator. Environmental Protection Agency (EPA) certified Diesel
Fueled Engine. Certification of Year 2000 compliance by manufacturer.
Engine and Generator Specifications: 120/240 VAC 60 Hz single phase.
Brushless, permanent magnet exciter. Solid state volts/Hz voltage
regulator with 1% no load to full load regulation. 100% of rated kW
one-step load acceptance per NFPA 110. Short-circuit capability
enabling downstream circuit breakers to trip without collapsing the
generator field. Compliance with NEMA, IEEE, and ANSI standards for
temperature rise. Electronic isochronous governor. Frequency regulation
of < 0.5% when loaded. Integral vibration isolation. Controller and
overload protection with Indicators and Warnings for: Keyed start
switch (key removable when off or running). Audio/visual annunciation
with NFPA-110, Level 2 capability. Remote start, prime power, and
remote annunciation capability. Analog Gauges/Meters 2% Accuracy. Oil
Pressure gauge, Tachometer, hourmeter, Temperature gauge (Engine
Coolant), Voltmeter VDC (Battery), Wattmeter, AC Ammeter, AC Voltmeter,
Frequency Meter. Engine audio/visual alarms and required automatic
engine shutdown: Low Oil Pressure, High Coolant Temperature, Engine
Overspeed/Overcrank. Sound Attenuated Enclosure: Drip proof sound
shielded weatherproof housing, sound shield vertical lifting eyes,
Removable/hinged pre-painted side panels w/ stainless latches w/ locks
keyed alike, Residential Exhaust Silencer installed (<69 dB(A) at
7 meters from generator set center 360 ), Vertical Exhaust pipe with
Rain Cap installed, Skid end caps installed if skid mounted. Trailer
(D.O.T. certified): Tandem Axle design, Axle Brakes (electric or
electro-hydraulic), Tongue Mounted Swivel Jack stand, Adjustable height
multi-purpose hitch assembly (2 5/16" ball in addition to Drawbar eye
with minimum eye opening of 2 3/8" and maximum eye crossection of 1
13/16" ). 200 gal UL listed fuel cell frame mounted in trailer and
connected. Fuel pressure gauge, Fuel level gauge, Low Fuel Level Alarm,
High Fuel Level Alarm, Fuel In Basin Alarm, vent caps, rear
stabilizers, rear heavy duty stabilizer jacks, safety chains. D.O.T.
approved lighting on sides and rear consisting of: 4 side lights (1
yellow front left and right, 1 red rear left and right), 4 rear lights
(2 red left, 2 red right), 7 pin male Commercial Truck wiring socket
mounted to trailer and connected, Radial Tires rated at 125% of fully
fueled wet weight of complete system. Accessories: Heavy Duty Air
Cleaner with air cleaner restriction indicator, Unit Mounted Radiator,
12 VDC Starting Batteries with battery rack and cabling installed, 100
Amp -- 600 VAC Line Shunt-Trip Circuit Breaker with emergency Shutdown
from both sides of trailer. Engine block heater installed and
connectable with side access covers shut, Oil drain extension and valve
installed for easy access from side of trailer, Initial fill of Lube
Oil and Antifreeze. Onsite installation, test and startup supervisedby
factory authorized representative, One (1) Year Comprehensive Factory
Warranty, Two (2) copies of Operations / Maintenance Manuals, one (1)
each air filter, one (1) each oil filter, one (1) each fuel filter,
and a list of recommended spare parts. Delivery Requirements: In less
than 12 weeks from placement of order including on-site delivery and
testing. A best value award will be made considering price and the
evaluation criteria outlined below. Evaluation criteria to be included
in paragraph (a) of provision 52.212-2 are as follows: (I) technically
acceptable, (II) lowest priced offeror. The following FAR provisions
(which can be downloaded at the following site:
http://www.epa.gov/oamrtpnc/spclaus/index.htm) apply to this
solicitation: 52.212-1, Evaluation-Instructions to Offerors-Commercial;
52.212-2, Evaluation-Commercial Item. All offerors are to include with
their offers a completed copy of provision 52.212-3, Offeror
representations and Certification-Commercial Items. The following FAR
clause applies to this acquisition: 52.212-4, Contract Terms and
Conditions-commercial Items. The following additional FAR clauses which
are cited in clauses 52.212-5 are applicable to the acquisition:
52.203-6, Restrictions on Subcontractor Sales to the Government, with
Alternate I: 52.203-10, Price or Fee Adjustment for Illegal or Improper
Activity; 52.219-14, Limitation on Subcontracting; 52.222-26, Equal
Opportunity, 52.222-35, Affirmative Action for Special Disabled and
Vietnam Era Veterans; 52.222-36, Affirmative Action for Handicapped
Workers: 52.222-37, Employment Reports on Special Disabled Veterans and
Veterans of the Vietnam Era; 52.225-3, Buy American Act -- Supplies.
Cost and technical information should be submitted to Joel P. Smith,
Contract Specialist, U.S. Environmental Protection Agency, MD-33,
Research Triangle Park, NC 27711. Courier Delivery Address is: U.S.
Environmental Protection Agency, Receptionist-Administration Bldg.
Lobby, Attn: Joel P. Smith, 79 T.W. Alexander Drive, Research Triangle
Park, NC 27709. All offers are due by September 22, 1999, 4:00 PM ET.
No telephonic requests will be honored. Posted 09/10/99 (W-SN378933).
(0253) Loren Data Corp. http://www.ld.com (SYN# 0263 19990914\61-0002.SOL)