COMMERCE BUSINESS DAILY ISSUE OF SEPTEMBER 17,1999 PSA#2434Contracts Department, P. O. Drawer 43019, MCLB, Albany, GA 31704-3019 E -- COMMERCIAL PROCUREMENT OF THREE MODULAR BUILDINGS SOL
M67004-99-Q-0060 DUE 091599 POC Sgt D. J. Jones, Code 89-1,
(912)439-6715 This is a combined synopsis/solicitation for commercial
items prepared in accordance with the format in Subpart 12.6, as
supplemented with additional information included in this notice. This
announcement constitutes the only solicitation; proposals are being
requested and A WRITTEN SOLICITATION WILL NOT BE ISSUED. This
requirement is being issued as a Request for Quotation. Solicitation
document and incorporated provisions and clauses are those in effect
through Federal Acquisition Circular 97-13 and Defense Acquisition
Circular 91-13. This action is restricted to small businesses. The
following is a list of requirements: Line Item 0001 -- (2) modular
buildings with the following specifications: each building to be 10'
wide x 16' long and of the manufactures standard height. Panels shall
be a minimum of 3" thick, exterior facing shall be a minimum of 26
gauge painted stucco-embossed steel. Interior facing to be 5/8' thick
fire rated expanded honeycomb of polystyrene with a minimum "R" rating
of 12.Post shall be constructed of 6063-T6 aluminum extrusions. Posts
are to have a clear anodized finish. Post are to be connected with
screws spaced a maximum of 24" center-to-center of screw hole. Each
building shall have a minimum of four windows. Windows are to be of the
manufactures standard size and shape. Each building shall have a
minimum of two doors. Doors are to be of the manufactures standard
shape and size. Doors are to be located on the 16' side walls. One on
each wall with windows on each side of the door. Building roof shall be
constructed of steel panels. The panels shall be a minimum of 22 gauge
steel. Building electrical and lighting shall be of the manufactures
standard type for a 10' x 16' building. Building shall be wired and
lighted for use with 110/115 volt single phase 60hz electrical power.
Hardware shall be of commercial grade. Building ceiling shall be of the
suspended type. Ceiling panels shall be of the acoustical type. Each
building shall have one heating/cooling unit to be manufactures
standard size for a 10' x 16' building. Heating/cooling unit shall
operate on a 110 volt single phase. Building exterior shall be a light
tan color. All blue prints, plans, schematics, diagrams, and
instructions required for assembly of the building shall be furnished
by the manufacture. Building shall be packaged for shipment using the
manufactures standard package method. Building to be assembled by the
manufacture of the manufacture representative. Line Item 0002 -- (1)
Exterior building on mezzanine base to be 10' wide x 16' long and of
the manufactures standard height. Panels shall be a minimum of 3"
thick, exterior facing shall be a minimum of 26 gauge painted
stucco-embossed steel. Interior facing to be 5/8" thick faire rated
gypsum (type X) board clad in a light tan color vinyl. Panel core shall
consist of either expanded honeycomb of polystyrene with a minimum "R"
rating of 12. Post shall be constructed of 6063-T6 aluminum
extrusions. Posts are to have a clear anodized finish. Post are to be
connected with screws spaced a maximum of 24" center-to-center of screw
hole. Each building shall have a minimum of four windows. Windows are
to be of the manufactures standard size and shape. Each building shall
have a minimum of two doors. Doors are to be of the manufactures
standard shape and size. Doors are to be located on the 16' side walls.
One on each wall with windows on each side of the door. Building roof
shall be constructed of steel panels. The panels shall be a minimum of
22 gauge steel. Roof panels to be weatherproof. Building electrical
and lighting shall be of the manufactures standard type for a 10' x 16'
building. Building shall be wired and lighted for use with 110/115 volt
single phase 60hz electrical power. Hardware shall be of commercial
grade. Building ceiling shall be of the suspended type. Ceiling panels
shall be of the acoustical type. Each building shall have one
heating/cooling unit to be manufactures standard size for a 10' x 16'
building. Heating/cooling unit shall operate on a 110 volt single
phase. Building exterior shall be a light tan color. All blue prints,
plans, schematics, diagrams, and instructions required for assembly of
the building shall be furnished by the manufacture. Building shall be
packaged for shipment using the manufactures standard package method.
Building to be assembled by the manufacture of the manufacture
representative. Delivery shall be F.O.B. Destination, MCLB Albany, GA
31704 with inspection/acceptance at destination. Delivery Best
Possible, after award. FAR Clauses/Provisions: 52.203-3, Gratuities,
52.212-1, Instructions to Offerors Commercial Items, The Government
will award a contract resulting from this solicitation to the
responsible offeror whose offer conforming to the solicitation, is
considered to be the best value to the Government. The following
factors shall be used to evaluate offers: Price and technical
characteristics. 52.212-4, Contract Terms and Conditions Commercial
Items, 52.212-5, Contract Terms and Conditions Required to Implement
Statues or Executive Orders Commercial Items (incorporating 52.222-35,
Affirmative Action for Special Disabled and Vietnam Era Veterans,
Affirmative Action for Handicapped Workers, 52.222-37, Employment
Reports on Special Disabled Veterans and Veterans of the Vietnam Era,
52.225-3, Buy American Act Supplies, commercial Items apply to this
acquisition. The contractor shall extend to the Government the full
coverage of any standard commercial warranty normally offered in a
similar commercial sale, provided such warranty is available at no
additional cost to the Government. Offerors responding to this
announcement must provide the information contained in 52.212-1,
Instruction to Offerors Commercial Items. The offeror should also
provide its Commercial and Government Entity (Cage) code, Contractor
Establishment code (DUNS number) and Tax Identification Number.
Contractors must be registered in the Central Contractor Register to be
eligible for award. If a change occurs in this requirement, only those
offerors that respond to this announcement within the required time
frame will be provided any changes/amendments and considered for future
discussions and/or award. The written quotes and the above required
information must be received at this office on or before 1 October
1999, at 2:00 PM Eastern STD. Time. All responsible sources may submit
a quote which will be considered by the Marine Corps Logistics Base,
Albany, GA Contracting Dept. FAX (912)439-6791 Posted 09/15/99
(W-SN380433). (0258) Loren Data Corp. http://www.ld.com (SYN# 0024 19990917\E-0001.SOL)