Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF SEPTEMBER 17,1999 PSA#2434

Contracts Department, P. O. Drawer 43019, MCLB, Albany, GA 31704-3019

E -- COMMERCIAL PROCUREMENT OF THREE MODULAR BUILDINGS SOL M67004-99-Q-0060 DUE 091599 POC Sgt D. J. Jones, Code 89-1, (912)439-6715 This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and A WRITTEN SOLICITATION WILL NOT BE ISSUED. This requirement is being issued as a Request for Quotation. Solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 97-13 and Defense Acquisition Circular 91-13. This action is restricted to small businesses. The following is a list of requirements: Line Item 0001 -- (2) modular buildings with the following specifications: each building to be 10' wide x 16' long and of the manufactures standard height. Panels shall be a minimum of 3" thick, exterior facing shall be a minimum of 26 gauge painted stucco-embossed steel. Interior facing to be 5/8' thick fire rated expanded honeycomb of polystyrene with a minimum "R" rating of 12.Post shall be constructed of 6063-T6 aluminum extrusions. Posts are to have a clear anodized finish. Post are to be connected with screws spaced a maximum of 24" center-to-center of screw hole. Each building shall have a minimum of four windows. Windows are to be of the manufactures standard size and shape. Each building shall have a minimum of two doors. Doors are to be of the manufactures standard shape and size. Doors are to be located on the 16' side walls. One on each wall with windows on each side of the door. Building roof shall be constructed of steel panels. The panels shall be a minimum of 22 gauge steel. Building electrical and lighting shall be of the manufactures standard type for a 10' x 16' building. Building shall be wired and lighted for use with 110/115 volt single phase 60hz electrical power. Hardware shall be of commercial grade. Building ceiling shall be of the suspended type. Ceiling panels shall be of the acoustical type. Each building shall have one heating/cooling unit to be manufactures standard size for a 10' x 16' building. Heating/cooling unit shall operate on a 110 volt single phase. Building exterior shall be a light tan color. All blue prints, plans, schematics, diagrams, and instructions required for assembly of the building shall be furnished by the manufacture. Building shall be packaged for shipment using the manufactures standard package method. Building to be assembled by the manufacture of the manufacture representative. Line Item 0002 -- (1) Exterior building on mezzanine base to be 10' wide x 16' long and of the manufactures standard height. Panels shall be a minimum of 3" thick, exterior facing shall be a minimum of 26 gauge painted stucco-embossed steel. Interior facing to be 5/8" thick faire rated gypsum (type X) board clad in a light tan color vinyl. Panel core shall consist of either expanded honeycomb of polystyrene with a minimum "R" rating of 12. Post shall be constructed of 6063-T6 aluminum extrusions. Posts are to have a clear anodized finish. Post are to be connected with screws spaced a maximum of 24" center-to-center of screw hole. Each building shall have a minimum of four windows. Windows are to be of the manufactures standard size and shape. Each building shall have a minimum of two doors. Doors are to be of the manufactures standard shape and size. Doors are to be located on the 16' side walls. One on each wall with windows on each side of the door. Building roof shall be constructed of steel panels. The panels shall be a minimum of 22 gauge steel. Roof panels to be weatherproof. Building electrical and lighting shall be of the manufactures standard type for a 10' x 16' building. Building shall be wired and lighted for use with 110/115 volt single phase 60hz electrical power. Hardware shall be of commercial grade. Building ceiling shall be of the suspended type. Ceiling panels shall be of the acoustical type. Each building shall have one heating/cooling unit to be manufactures standard size for a 10' x 16' building. Heating/cooling unit shall operate on a 110 volt single phase. Building exterior shall be a light tan color. All blue prints, plans, schematics, diagrams, and instructions required for assembly of the building shall be furnished by the manufacture. Building shall be packaged for shipment using the manufactures standard package method. Building to be assembled by the manufacture of the manufacture representative. Delivery shall be F.O.B. Destination, MCLB Albany, GA 31704 with inspection/acceptance at destination. Delivery Best Possible, after award. FAR Clauses/Provisions: 52.203-3, Gratuities, 52.212-1, Instructions to Offerors Commercial Items, The Government will award a contract resulting from this solicitation to the responsible offeror whose offer conforming to the solicitation, is considered to be the best value to the Government. The following factors shall be used to evaluate offers: Price and technical characteristics. 52.212-4, Contract Terms and Conditions Commercial Items, 52.212-5, Contract Terms and Conditions Required to Implement Statues or Executive Orders Commercial Items (incorporating 52.222-35, Affirmative Action for Special Disabled and Vietnam Era Veterans, Affirmative Action for Handicapped Workers, 52.222-37, Employment Reports on Special Disabled Veterans and Veterans of the Vietnam Era, 52.225-3, Buy American Act Supplies, commercial Items apply to this acquisition. The contractor shall extend to the Government the full coverage of any standard commercial warranty normally offered in a similar commercial sale, provided such warranty is available at no additional cost to the Government. Offerors responding to this announcement must provide the information contained in 52.212-1, Instruction to Offerors Commercial Items. The offeror should also provide its Commercial and Government Entity (Cage) code, Contractor Establishment code (DUNS number) and Tax Identification Number. Contractors must be registered in the Central Contractor Register to be eligible for award. If a change occurs in this requirement, only those offerors that respond to this announcement within the required time frame will be provided any changes/amendments and considered for future discussions and/or award. The written quotes and the above required information must be received at this office on or before 1 October 1999, at 2:00 PM Eastern STD. Time. All responsible sources may submit a quote which will be considered by the Marine Corps Logistics Base, Albany, GA Contracting Dept. FAX (912)439-6791 Posted 09/15/99 (W-SN380433). (0258)

Loren Data Corp. http://www.ld.com (SYN# 0024 19990917\E-0001.SOL)


E - Purchase of Structures and Facilities Index Page