COMMERCE BUSINESS DAILY ISSUE OF SEPTEMBER 23,1999 PSA#2439CH2M Hill, Inc., 613 NW Loop 410, Suite 200, San Antonio, TX 78216 Y -- PRIVATIZATION OF UTILITY SYSTEMS:CONVEYANCE AUTHORITY AT KULIS
AIR NATIONAL GUARD BASE, ALASKA DUE 101599 POC For the U.S. Air Force:
CH2M HILL, 301 West Northern Lights Blvd. Suite 601 Anchorage AK
99503-2691 POC: Floyd J. Damron, P.E., Alaska Office Manager
(fdamron@ch2m.com), Tel (907) 278-2551 E-MAIL: Floyd J. Damron, P.E.,
Alaska Office Manager, fdamron@ch2m.com. PRIVATIZATION UNDER 10 USC
2688, UTILITY SYSTEMS: CONVEYANCE AUTHORITY AT KULIS AIR NATIONAL GUARD
BASE (ANCHORAGE INTERNATIONAL AIRPORT ANGB), ALASKA, DUE: 101599
POTENTIAL SOURCES SOUGHT PURPOSE: The Air Force seeks to identify
responsible potential sources and obtain information in regards to
privatization of utility systems in accordance with 10 USC 2688,
"Utility Systems: Conveyance Authority". The Commander of Kulis Air
National Guard Base is seeking interest and information specifically
for the potential privatization of the water, wastewater, and natural
gas utility systems at Kulis Air National Guard Base, Alaska.
OBJECTIVE: Should privatization result, the ownership of Kulis Air
National Guard Base's potable water, wastewater, and natural gas
utility systems, operation and maintenance, and obligation to continue
to provide utility service for an indefinite and ongoing period will
transfer to a utility service provider. All responsibility for
maintaining reliable utility service, including such items as
environmental compliance, maintenance costs, major system renovations,
construction, equipment, manpower, and overhead costs will become the
utility service provider's responsibility. It is intended that the
privatization will ultimately reduce the Air Force's life-cycle costs
for operating and maintaining utility systems and services. SYSTEM
DESCRIPTIONS: The following information provided is only an estimate
and is subject to change. Water -- Water is supplied to the Base by the
city through two 16-inch metered main city feeds. The Base water
distribution piping system includes approximately 15,200 feet of mostly
newer ductile iron pipe mains that have been installed since 1991.
Wastewater -- Wastewater is collected on-base in a gravity collection
system that discharges to a city-owned main that runs through the
facility. Wastewater treatment is provided by the city. The Base
collection system includes approximately 5,000 feet of 6-inch to 8-inch
sewer mains. The sewer collection system wasconstructed between the
1950s and 1990s and includes ductile iron, asbestos cement and cast
iron pipe. Natural Gas -The natural gas distribution system at Kulis
ANGB receives gas from Enstar through a gate station at 15 psig for
distribution throughout the base. There are no pressure reducing
stations in the system. The system has approximately 6,700 feet of PE
pipe. The pipe sizes range from 4-inches to 5/8-inches in diameter.
Annual consumption is approximately 39 million cubic feet. The primary
use of the gas is for heating purposes. PROCEDURES: This request to
interested parties is for gathering information and is a required
component of a systematic process to evaluate the interested parties
under the Air Force utilities privatization program. In order to
minimize costs both to potentially interested parties and to the
government, this notice is being issued to determine the interest and
feasibility of proceeding with a formal request for proposals. Should
insufficient credible interest be identified for a privatization
action, it is highly likely that no formal solicitation will be issued.
SHOULD INTEREST BE DETERMINED SUFFICIENT, A FORMAL REQUEST FOR
PROPOSALS MIGHT BE FORTHCOMING. Small Business interests shall note the
FAR Part 19 Standard Industrial Codes (SIC) and Size Standards for the
utility systems identified in this announcement. Some, all, or any
combination of the following may apply. SIC/SS: 4911/4Million (M)
Megawatt-hours, 4922/$5M, 4923/$5M, 4924/500, 4925/$5M, 4931/$5M,
4932/$5M, 4939/$5M, 4941/$5M, 4952/$5M, 4953/$6M, 4959/$5M, 4961/$9M,
4971/$5M. REQUESTED RESPONSE: Interested parties should provide a
statement of interest on company letterhead (not to exceed 20 pages in
length). The statement should include as a minimum the following
criteria: (1) specific utility system(s) of interest and desired
bundling/grouping of utilities to purchase; (2) capability and
experience in ownership, operation and maintenance of similar utility
systems; (3) financial capacity to purchase, expand, and operate the
utility systems; (4) statement detailing the understanding of the
obligation to serve in regards to continuous utility service; (5)
conceptual rate plan (excluding numerical analysis or proposed rates);
i.e., will charges for utility service be made from existing rates or
from rates developed specifically for service at the individual
base(s); (6) ideas regarding conjunctive metering and billing for
service on base (excluding numerical analysis or proposed rates); (7)
discussion of your conceptual basis (excluding numerical analysis or
proposed price) for a proposed purchase price (capitalized earnings
value, replacement cost new less depreciation, original cost less
depreciation, or other); (8) statement detailing your understanding of
applicable state and local utility laws and your compliance
capability; (9) statement detailing your understanding of any existing
franchises and your ability to provide service given these conditions;
(10) statement detailing your understanding of federal, territorial,
and local environmental laws and regulations and familiarity and
experience with environmental compliance procedures and regulations for
Alaska and the U. S. Environmental Protection Agency; and (11) business
size (large, small, small-disadvantaged; 8(a); women-owned). Elaborate
proposals or pricing information is neither required nor desired.
Under no circumstances will cost data for the existing systems be
provided. Any innovative and new conceptual ideas to achieve the stated
objective are encouraged. If a site visit and the provision of
additional data are later determined necessary, notification will be
provided by way of an amendment to this announcement. It should be
noted that the RFIs for different Air Force bases and utility systems
might be issued in the same time frame. A separate response to each RFI
is required. Please respond electronically as well as with hard copy.
The point of contact is CH2M HILL, 301 West Northern Lights Blvd. Suite
601 Anchorage AK 99503-2691 POC: Floyd J. Damron, P.E., Alaska Office
Manager (fdamron@ch2m.com), Tel (907) 278-2551. Posted 09/21/99
(W-SN382600). (0264) Loren Data Corp. http://www.ld.com (SYN# 0127 19990923\Y-0015.SOL)
Y - Construction of Structures and Facilities Index Page
|
|