Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF SEPTEMBER 29,1999 PSA#2443

Fleet and Industrial Supply Center, Puget Sound, Bldg 467 W Street, Code 200 Bid Desk, Bremerton, WA 98314-0051

61 -- STATIC FREQUENCY CONVERTER SOL N00406-99-R-5249 DUE 111799 POC Maureen Renville (360)476-7772 E-MAIL: Contracting Officer, maureen_renvill@puget.fisc.navy.mil. Static Frequency Converters (SFC) capable of converting Type I, 60 jertz (HZ), 440 volts, 3-phase power as defined in MIL-STD-1399 (NAVY) to 400 HZ power.b. This is a 100% Small Business Set-Aside. To be procured as an Indefinite Quantity, Indefinite Delivery Contract. Minimum requirement will be the 1st Article. Total quantity is one each 1st Article; 52 each as follows: 1st Option period (FY2002) -- 22 each; 2nd Option period (FY2003)- 18 each; 3rd Option period (FY2004)- 10 each; and 4th Option period (FY2005) -- 2 each. Unit shall be designed so that each can be paralleled with an identical SFC with an output of 10 KVA. Fuses shall be kept to a minimum consistent with protection of various components within the SFC. Circuitry shall be of solid state design. SFC shall use IGBT technology or newer. All electrical components including relays, switches and wiring shall conform to and be located in accordance with applicable NEMA, ANSI and NFPA standards for the intended application. A supply circuit disconnect device shall be provided and installed on the SFC. Main and auxillary controlcircuits shall operate on a circuit of 115 volts or less derived from isolation transformer(s) integral with the equipment. All exposed, non-current carring metal parts on the SFC shall be maintained at common, zero ground potential. None of the primary circuits in the equipment shall be connected to ground. Solid state design shall be employed throughout for electronic components. Performance requirements: a) The overall nput/output efficiency at rated load shall be 70%. b) The SFC will provide MIL-STD-1399 (NAVY) Type I power within the following parameters: OUTPUT power -- 120 V AC; NO OF PHASES-3; TYPE OF CONNECTION -- Delta; CONTINUOUS POWER OUTPUT RATING -- 5 k VA; OUTPUT FREQUENCY -- 400 Hz. The SFC shall operate satisfactorily under any of the following conditions: a) Ambient Temperature Range -- 0 to 55 degrees C; b) Ambient Humidity Range 0 to 95% relative humidity. MAXIMUM dimension including requiredshock mounts and cable pull boxes: Height -- 60'; Width -- 24"; Depth -- 38" (with max service envelope of 57'). FIRST ARTICLE TESTS to include the following: a) vibration IAW MIL-STD-167; b) shock IAW MIL-S-901; c) Electromagnetic interference characteristics IAW MIL-STD-461; d) Ferrous Magnetic Field Test and Stray Magnetic Field Test; e) 250-hour life test. Production Unit(s) test to include Operational Test and Manufacturing Reliability Test. Data Items to be provided are: a) First Article Test Procedures and Reports; b) Production Test Procedures and Reports; c) Engineering Drawings and Associated Lists (parts/tools); d) PTD documentation or Standard Commercial Manuals if information containedwithin meets or exceeds the PTD requirements. Delivery of First Article desired 90 days after date of contract. Inspection at source, inspection at destination, Puget Sound Naval Shipyard, Bremerton, WA 98314-5100. Notes 1,9,and 26 apply. All responsible sources may submit offer/bid which shall be considered by FISC Puget Sound. Telephone requests will not be honored. Fax requests to (360)476-2931 or e-mail bid_officer@puget.fisc.navy.mil. Posted 09/27/99 (W-SN385066). (0270)

Loren Data Corp. http://www.ld.com (SYN# 0248 19990929\61-0002.SOL)


61 - Electric Wire and Power and Distribution Equipment Index Page