COMMERCE BUSINESS DAILY ISSUE OF OCTOBER 28,1999 PSA#2464Commander, Lantnavfacengcom, 1510 Gilbert Street, Norfolk, VA
23511-2699 (attn: Code 0222) Z -- TARAWA TERRACE II HOUSING REPLACEMENT, MARINE CORPS BASE, CAMP
LEJUNE, NORTH CAROLINA SOL N62470-97-B-7111 DUE 120899 POC Printing
Assistant, Priscilla Schaefer, 757-444-5968 -- Contract Specialist,
Sharon A. Taylor, 757-322-8258 E-MAIL: Contract N62470-97-B-7111
Modification, TaylorSA@efdlant.navfac.navy.mil. Correction: This action
published in the CBD on 22 October 1999 is amended as follows: This
project solicits a Two Phase Design/Build construction contract for
demolition of existing housing and construction of 200-400 two and
three bedroom new townhouse units at the Tarawa Terrace II area of MCB
Camp Lejeune, North Carolina. Exterior living area to include privacy
fencing, exterior storage sheds and landscaping. Site improvements may
include modifications to existing infrastructure as required for
construction of the new family housing units. As part of the technical
proposal, a master development plan for the Tarawa Terrace I and II
1,845 unit complex shall be developed. New townhouse units will reflect
the scheme presented in the master plan. The contractor shall provide
all labor, supervision, engineering, materials, equipment, tools,
parts, supplies and transportation to perform all work described in the
specifications. Contract also includes a housing office and self-help
warehouse. Requirements for the technical Source Selection criteria
factors are as follows: PHASE ONE FACTORS: (1) Corporate Experience;
subfactors (1A) Relevant Experience (1A1) Construction Team; (1A2)
Design Team; and subfactors (1B) Key Personnel; (1B1) Construction
Team; (1B2) Design Team; (2) Past Performance; subfactors (2A) Teams
Past Performance; (2A1) Construction Team; (2A2) Design Team; and
subfactors (2B) Experience Modification Rating; (2B1) Construction
Team; (2B2) Design Team; (3) Small Business Subcontracting Effort;
sub-factor (3A) Past Performance. PHASE ONE EVALUATION CRITERIA WILL
ADDRESS TECHNICAL ONLY, PRICE WILL NOT BE A CONSIDERATION DURING THIS
PHASE. PHASE TWO FACTORS: (A) Small Business Subcontracting Effort,
subfactor (1) Subcontracting Plan Effort; (B) Technical Solutions;
subfactors (1) Design Solution Narratives; (2) Concept floor plans,
elevations, and site plans; (3) Master plan for Tarawa Terrace; (4)
Proposed schedule; and (5) sustainable Design Features; and (C) Price.
A maximum of five offerors selected during PHASE ONE will advance to
PHASE TWO. Offerors will be evaluated on both technical and price
proposals during this phase. Overall technical and price factors will
be equal in significance. The government reserves the right to reject
any or all proposals prior to award; to negotiate with any or all
proposers; to award the contract to other than the lowest total price;
and to award to the proposer submitting the proposal determined by the
government to be the most advantageous to the government. PROPOSERS ARE
ADVISED AN AWARD MAY BE MADE IN PHASE TWO WITHOUT DISCUSSION OR ANY
CONTACT CONCERNING THE PROPOSALS RECEIVED. Proposers should not assume
they will be contacted, or afforded the opportunity, to qualify,
discuss, or revise their proposals. However, the Government may contact
proposers for the purpose of clarifying aspects of their proposal. The
Government also reserves the right to enter into discussions if deemed
necessary, and if discussions are conducted the proposers will be
afforded theopportunity to revise their proposals. The Request for
Technical Proposals for PHASE ONE will be issued approximately 8
November 1999. The receipt date for PHASE ONE Technical Proposals is
approximately 8 December 1999 at 2:00 p.m. Price and technical
proposals for PHASE TWO will be requested after the competitive range
has been established. This solicitation is available in electronic
format only. All documents will be in the Adobe Acrobat PDF file format
on CD ROM. The free Acrobat Reader, required to view the PDF files, is
provided on the CD or can be downloaded from the Adobe website. A
charge will be made for each CD. The cost is $12.50 for the CD. This
price includes priority mail postage. These sets will be made available
upon receipt of a written request, and a non-refundable check or money
order made payable to the U.S. Treasury. Written requests shall be
sent to: DEFENSE AUTOMATED PRINTING SERVICE, ATTN: PRISCILLA SCHAEFER,
1641 MORRIS STREET, BUILDING KBB, NORFOLK, VIRGINIA 23511-2898. Please
state area code, telephone number, street address, nine-digit zip code
and whether you are participating as a prime or subcontractor. Any
inquiries regarding plans and specifications shall be directed to Ms.
Priscilla Schaefer at 757-444-5968. A copy of the planholder's list can
be obtained on the internet at www.norfolk.sebt.daps.mil. Technical
inquiries shall be faxed to 757-322-8264, Attention: Sharon A. Taylor,
Code 02223. The Estimated Cost Range is between $10,000,000 and
$25,000,000. The Standard Industrial Classification (SIC) Code for this
project is 1521 with a Size Standard of $17,000,000. This project is
not set aside for small business. Large businesses shall submit a
subcontracting plan prior to award of the contract. Funding for this
project is available in the amount of $24,000,000. Posted 10/26/99
(W-SN394972). (0299) Loren Data Corp. http://www.ld.com (SYN# 0107 19991028\Z-0006.SOL)
Z - Maintenance, Repair or Alteration of Real Property Index Page
|
|