Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF NOVEMBER 10,1999 PSA#2473

SA-ALC/Contracting Directorate/LDKSG; 485 Quentin Roosevelt Road Suite 12; Kelly AFB, TX 78241-6419

66 -- AUTOCOLLIMATOR/NSN 6650-01-201-7591/PN 142/13 SOL F41608-00-Q-13076 DUE 123099 POC The Point of Contact is Ron Carter, LDKSG, Phone: 210 925 4348, FAX: 210 925 6555, E-MAIL: ron.carter@kelly.af.mil E-MAIL: Send your E-Mail request to the POC, ron.carter@kelly.af.mil. Noun: Autocollimator; Qty: 7 ea; Deliv date: 31 Mar 2000; Applicable to the PMEL and other multiple uses; Approved Source: Taylor Hobson (CAGE: 64790); Predominant Material: Metal, Optical lens; Size: 10.5" L, 3" D, 7 lbs Function: the minimum requirement is for a single axis micrometer with 10 min of arc range and 0.5 sec accurancy over 1 min and 2 sec accuracy over 10 min. the linsturment may be rotated through 90 degrees to measure in the second plane perpendicular to the first. The 142/13 (TA51) microptic dual axis autocollimator includes the 142/76 leveling base, lamp with transformer and rheostat, storage case and any other items required for a complete item ready for use, except reflector. Unapproved sources shall include a source approval evaluation package with their quote. All potential offerors should contact the buyer/PCO identified in this notice for additional information and/or to communicate concerns, if any, concerning this acquisition. If your concerns are not satisfied by the contracting officer, an Ombudsman has been appointed to hear concerns from offerors or potential offerors during the proposal development phase of an acquisition. The Ombudsman does not diminish the authority of the program director or Contracting Officer, but communicates Contractor concerns, issues, disagreements, and recommendations to the appropriate Government personnel. When requested, the Ombudsman shall maintain strict confidentially as to the source of the concern. The Ombudsman does not participate in the evaluation of proposals or in the source selection process. Interested parties are invited to call the SA-ALC Acquisition Ombudsman at AC 210-925-5133 or send E-Mail to: ombudsman@www.kelly-afb.org. Buyer's name (point of contact listed above) should be included on all solicitation requests. In addition, please include a FSCM/cage code for mailing purposes. Posted 11/08/99 (D-SN399154). (0312)

Loren Data Corp. http://www.ld.com (SYN# 0209 19991110\66-0003.SOL)


66 - Instruments and Laboratory Equipment Index Page