Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF NOVEMBER 12,1999 PSA#2474

Fluor Daniel Fernald, P.O. Box 538704, Cincinnati, OH 45253-8704

Y -- CONSTRUCTION OF STRUCTURES AND FACILITIES -- MODULAR LABORATORY DUE 111799 POC James Reuter (513) 648-5166 Amended Submission No. 377892 Dated September 8, 1999. Summation of amendments: 1. Experience changed from 5 years to 3 years. 2. "Proposer and lower tier subcontractor" changed to "Proposer, lower tier subcontractor, and/or company representative." 3. Small business set-aside added. Fluor Daniel Fernald (FDF) and the Department of Energy (DOE) have prepared and approved a plan to construct a 4872 square foot modular laboratory at the Fernald Environmental Management Project (FEMP) located in Fernald, Ohio. In addition, the modular laboratory facility will utilize three existing DOE owned road transportable analytical laboratories (RTAL's) to provide analytical service to the site during final remediation activities. Work will include but is not limited to: site clearing and grubbing; excavation and installation of underground piping; foundation installation; design, system, fume hoods, case work, utility piping, and countertops; fire alarm installation, HEPA extension; communication systems including telephone, evacuation, and computer; utility piping installation; ramps, stairways, and walkway installation. Potential proposers must meet the pre-qualification criteria listed below: 1. (3) years experience in the set-up and installation of modular structures. 2. (3) years experience in the performance of government contracts ranging in price from 1-5 million dollars. 3. The proposer, lower tier subcontractor, and/or a company representative must be familiar with excavation and installation of foundations, sanitary sewer, lift stations, and domestic water. 4. The proposer, lower tier subcontractor, and/or a company representative must possess (3) years experience in the installation of 13.2KV overhead electric, transformers, pole lines, disconnects, fire alarm, and communications systems. 5. The proposer, lower tier subcontractor, and/or a company representative must possess (3) years experience in the design, fabrication, and installation of modular laboratory buildings including HVAC design, fume hood ventilation, case work and finishings, specification, HEPA Filter and installation of mechanical and utility systems. 6. The proposer shall be classified as a small business as this procurement will be a small business set-aside. 7. Safety Performance Information: A. Proposers and lower tier subcontractors shall have a record of good safety performance to be determined responsible and, therefore, eligible for any award on projects managed by Fluor Daniel at the Fernald Environmental Management Project in Fernald, Ohio. B. To be considered responsible, a proposer must be able to demonstrate to the satisfaction of Fluor Daniel that it has a record of safe performance as demonstrated by a current workers compensation insurance experience modification rate (EMR) of less than or equal to 1.)); or the trend for the past three years is downward and one of the past three years had an EMR greater than 1.15; or for proposers that are too small, too new or self-insured, has an OSHA recordable incident rate of less than or equal to 10 injuries and illnesses per 200,000 man ours for the past calendar year. Each proposer shall submit the information required with their qualifications. C. Firms who cannot meet the safety rates or special criteria described in paragraph B above, but nevertheless desire to submit their qualifications may do so on the following conditions: 1. Include a narrative statement as to the reason(s) for not being able to meet the criteria and request Fluor Daniel consideration of any special circumstances that relate to its rating. 2. Fluor Daniel will evaluate the firm's request for special consideration and acceptability of the bid. 3. The firm (proposer) agrees that the Fluor Daniel evaluation and decision as to acceptability for this solicitation is final and is not subject to discussions of any type between Fluor Daniel and the proposer and is not subject to any appeal or dispute. Proposer should send their resume of qualifications to: James Reuter, Fluor Daniel Fernald, P. O. Box 538704 Cincinnati, Ohio 45253 Telephone: (513) 648-5166 Posted 11/09/99 (W-SN399411). (0313)

Loren Data Corp. http://www.ld.com (SYN# 0129 19991112\Y-0007.SOL)


Y - Construction of Structures and Facilities Index Page