COMMERCE BUSINESS DAILY ISSUE OF NOVEMBER 19,1999 PSA#2479Department of Transportation, United States Coast Guard (USCG),
Commandant (G-ACS), U.S. Coast Guard Headquarters, 2100 Second St., SW,
Washington, DC, 20593-0001 J -- J-MAINTENACE AND SUPPORT SERVICES FOR THE INTEGRATED POWER PLANT
ABOARD THE USCGC HEALY SOL DTCG23-00-R-TBDHEALY POC Augustine Green,
Contract Specialist, Phone (202) 267-2530, Fax (202) 267-4019, Email
agreen@comdt.uscg.mil -- Donna Grimes, Contracting Officer, Phone (202)
267-0766, Fax (202) 267-4019, Email WEB: Visit this URL for the latest
information about this,
http://www.eps.gov/cgi-bin/WebObjects/EPS?ACode=P&ProjID=DTCG23-00-R-T
BDHEALY&LocID=14. E-MAIL: Augustine Green, agreen@comdt.uscg.mil. The
Coast Guard has a requirement to procure maintenance services for
maintaining the Integrated Power Plant (IPP) installed aboard the Coast
Guard_s Polar Icebreaker (USCGC Healy (WAGB-20)), as well as shore-side
support equipment. The maintenance support includes all management,
supervision, personnel, labor, material and equipment, which includes
technical representative visits or telephone consultations for
troubleshooting and repairing equipment via phone, facsimile, or
on-site visits (homeport and world wide, as required); configuration
management services; new/overhaul parts and replacement supply
(original equipment manufacturer or equal); and maintenance training.
The following list is not all inclusive, but covers the major IPP
components to be supported under this contract: Shipboard Equipment _
Main Generators-10,000 HP, Main Propulsion Cycloconverters 12 pulse,
Cycloconverter Transformers, Main Propulsion Motors-15,000 HP, Main
Motor Disconnect Units, High Voltage Switchgear and Control Units, S/S
Power Management and Distribution System-450V, S/S Motor Generator
Sets, S/S Transformers, Machinery Plant Control and Monitoring System
(MPCMS), Dynamic Positioning System (DPS), Oceanographic Winch Control
Systems, Trawl/Core Winch Control System, and Auxiliary Generator;
Shore-side Support Equipment _ Spare Propulsion Motor, 15,000 HP, Spare
Cycloconverter, MPCMS/DPS Training Console, Shore-side Special Purpose
Test Equipment and Shore-side CTES Equipment. The IPP is manufactured
by Alstom Drives and Control LTD (AD&CL) of Rugby, England. AD&CL also
has an office in Pittsburgh, PA. USCGC Healy_s homeport will be
Seattle, Washington. The Coast Guard needs maintenance support services
on or about 1 June 2000. The technical consultant must have at least 3
years hands-on experience in the troubleshooting, repair and
performance of preventative and corrective maintenance on equipment of
similar size and service to the Alstom equipment. The Coast Guard
anticipates a one-year contract with options to extend the contract not
to exceed nine additional years. The maintenance support contractor
shall maintain a quality program that complies with ISO-9001. All
interested parties must submit a capability statement that sufficiently
describes their qualifications, capabilities, and previous experience
relevant to fulfilling the above requirement. Capability statements
shall include evidence of at least five years experience/work on AD&CL
control systems with features/capability comparable to the systems to
be supported. This experience may be in system design, operation,
maintenance, and training or in any combination of these four
specialties. They must be intimately familiar with all components of
the HEALY systems listed and their function. Interested parties must
provide proof of access to AD&CL proprietary technical documentation on
systems hardware and software. Only partial technical
documentation/data is available to the Government. Access to AD&CL
documentation is required to enable tailoring/upgrade of MPCMS, DPS
software and/or hardware and replacement of technologically obsolescent
power plant components to meet future CG requirements. Parties must
also demonstrate the capability of accessing the ship's MPCMS/CTES from
a remote shore site and extracting data from MPCMS/CTES databases for
analysis and troubleshooting. This notice is not a solicitation nor is
a formal Request for Proposal available. Responses are due no later
than 15 days from the publication of this synopsis. In the absence of
responses for firms, which believe they have the capability to perform
this requirement, Coast Guard intends to negotiate with Alstom Drives
and Control LTD in Rugby, England, for the work described pursuant to
FAR 6.302-1(b)(1). Should the results of this synopsis justify a sole
source procurement as described in FAR 6.302-1, no other notice will
be published until award is made. All correspondence should be
addressed to: Commandant (G-ACS-5/AGS), 2100 Second Street SW,
Washington, DC 20593-0001_Note 22 applies. Signed: Donna Toliver
Grimes, Contracting Officer. Posted 11/17/99 (D-SN401343). (0321) Loren Data Corp. http://www.ld.com (SYN# 0043 19991119\J-0009.SOL)