Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF DECEMBER 7,1999 PSA#2490

NISE East Det. Norfolk, Contracts Division, Box 1376, Norfolk, VA 23501-1376

58 -- TRAVELING WAVE TUBE RF AMPLIFIER SOL N65236-00-R-1007 DUE 121199 POC L. Barnes (757)558-6631 E-MAIL: click here to contact the contracting officer via, barnesl@spawar.navy.mil. This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, or supplemented with additional information included in this notice. This announcement consititutes the only solicitation and a written solicitation will not be issued!! Solicitation N65236-00-R-1007 is issued as a request for proposal(RFP).!! This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 97-03.!! This is a competitive procurement under sic 3669. Logimetrics P/N A600/L-878A Traveling Wave Tube (TWT) RF Amplifier or equal. There is one contract line item clin 0001, 36 each Logimetrics model A600/L-878A or equal. Must be compatible with ANSRC-57(V) Digital Wideband Transmission System. Must have VSWR protection, front panel mounted Forward/Reflected power meter, internal safety interlock for any removable covers and RF safety interlock. RF Input/Output and AC connectors mounted on the rear of the unit. Broadband noise output less that -25dBm/MHz. Spurious noise output less than -40dBc at 30 MHz from any frequency in the band from 1350 to 1850 MHz. Principles of Operation: Operates on 115VAC, Single Phase, 50/60 Hz Power. Amplifies a 5 to 10 watt input FM signal to no less than 200 watts output over a frequency range of 1350 to 1850 MHz. Dimensions: Must be mountable in a 19" shipboard electronic equipment rack. No more than 14" high and 25" deep. Weight not to exceed 175 pounds. Must be air cooled and operate in a normal shipboard environment. Required delivery date is 30 Mar 2000; Place of delivery and acceptance is SPAWAR Systems Center Charleston, St. Juliens Creek Annex, Magazine Road, Bldg 59, Portsmouth, VA 23702; FOB: destination.!! Solicitation provision at FAR 52.212-1, Instruction to Offerors-Commercial Items (Oct 1995) is hereby incorporated by reference.!! A completed copy of the provision at 52.213-3, Offeror Representations and Certifications- Commercial Items, as well as 252.212-7000, Offeror Representations and Certifications-Commercial Items, and 252-225-7035, By American Act-North America Free Trade Agreement Implementation Act-Balance of Payment Program Certificate must be submitted with their offer.!! Clause 52.212-5, Contract Terms and Conditions Required to Implement Statutes or Executive Orders -- Commericial Items, is hereby incorporated by reference. The following paragraphs apply to this solicitation and any resultant contract (b)(2) 52.203-10, (b)(3) 52.219-8, (b)(6) 52.222-26, (b)(7) 52.222-35, (b)(8) 52.222-36, and (b)(9) 52.222-37.!! Clause 252.212.7001, Contract Terms and Conditions Required to Implement Statutes or Executive Orders applicable to Defense Acquisitions of Commercial Items, is hereby incorporated by reference, with additional DFAR clauses included in this solicitation and any resulting contract, as follows: 252-225-7036.!! Additional Terms and Conditions applicable to this procurement are: (i) Type of Contract: A firm fixed price contract under commercial acquisition procedures will be awarded.!! the Defense Priorities and Allocations Systems (DPAS) assigned rating for this procurement is unrated.!! Signed and dated offers (one original/three copies) must be submitted to Space and Naval Warfare Systems Center, St. Juliens Creek, P.O. Box 1376, Norfolk, VA 23501-1376, ATTN: L. Barnes (Code 1118) by close of business on December 11, 1999.!! See Note 22. Contact L. Barnes at 757-558-6631. Preliminary copies of Proposals may be faxed to (757)396-0714.!! Posted 12/03/99 (W-SN405570). (0337)

Loren Data Corp. http://www.ld.com (SYN# 0200 19991207\58-0007.SOL)


58 - Communication, Detection and Coherent Radiation Equipment Index Page