Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF DECEMBER 16,1999 PSA#2497

DOC; Mountain Administrative Support Center; Acquisition Management Division; 325 Broadway, MC3; Boulder, CO

66 -- 96 OZONESONDE SOL NRMAP1-171DT DUE 010300 POC Doris Turner, Purchasing Agent, 303-497-3872 or FAX: 303-497-3163 E-MAIL: NOAA; MASC Acquisition Management, Doris.P.Turner@noaa.gov. The National Oceanic and Atmospheric Administration (NOAA) proposes to negotiate on a sole source basis contract under the authority of 41 U.S.C. 253(c)(1) with ENSCI Inc. for 100 Ozonesonde Model 2Z with V2C Interface Boards with the following critical specifications: 1) Sensor for detecting ozone must be of the electrochemical concentration cell (ECC) type. 2) Pump must be non-reactive with ozone and capable of working in the altitude range of 0-35km. A thermistor for measuring pump temperature must be mounted in the pump. 3) Ozonesonde must be capable of measuring ozone with an accuracy and precision of 5 percent over the altitude range of 0-30km and for ozone mixing ratios of 0-15 parts per million = by volume. 4) Ozonesonde must provide an electronics interface with the Vaisala-80 radiosonde with the following capabilities: a) Capable of mounting within the chassis of = the ozonesonde and interconnecting with the sensor output and the pump thermistor with all connections provided. b) Provide powersource (battery) for interface board and pump operation. C) Capable of providing 1 second data output. D) Sensor current must be read with 12 bit accuracy. E) Be able to provide conversion of the Vaisala RS-80 pressure, temperature and humidity information as well as the ozonesonde sensor current and pump thermistor resistance = and produce a data stream that can be transmitted by the RS-80 radiosonde. F) Be compatible with the NOAA Climate Monitoring and Diagnostics Laboratory ozonesonde software and data processing routines. 5) Ozonesonde must be housed in a container that maintains the environmental conditions in the temperature range 10-30 degrees Celsius. 6) The ozonesonde and its container must weigh 1.5 kilograms or less. This procurement is being conducted per FAR Part = 13, Simplified Acquisition Procedures. This synopsis is issued for information only. No competitive solicitation is planned. No award will be made on the basis of requests in response to this notice. Information submitted in responseto this notice will be used solely to determine whether or not use of competitive procedures to fulfill this requirement would be in the Government=92s = best interest and must address qualifications pertinent to this requirement. Terms and Conditions and agency level protest procedures can be found on web site http://oamweb.osec.doc.gov/conops/#REFERENCE. Hard copy in full text available from office address and phone number listed in notice. Anticipated award date will be January 7, 2000. Posted 12/14/99 (D-SN408459). (0348)

Loren Data Corp. http://www.ld.com (SYN# 0229 19991216\66-0007.SOL)


66 - Instruments and Laboratory Equipment Index Page