Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF JANUARY 27,2000 PSA#2524

Officer in Charge of Construction, Naval Facilities Engineering Command, Contracts Marianas (Guam), PSC 455 Box 175, FPO 96540-2200

C -- ARCHITECT-ENGINEERING SERVICES FOR ASSESSMENT OF UNDERGROUND FUEL TANKS U-4 AND U-29 AT VARIOUS FUEL DEPARTMENT LOCATIONS, COMNAVMARIANAS, GUAM, M.I. SOL N62766-00-C-0010 DUE 022900 POC Ms. Julia Taitano, (671) 339-7467 or FAX (671) 339-4248 Architect-Engineer (A-E) services are requireed for Environmental Engineering Services Contract for assessment of underground fuel tanks U-4 and U-29, at various Fuel Department locations, COMNAVMARIANAS, Guam, M.I. The field work will include all required surveying, geological, soil boring, equipment cleaning, sampling, bore hole closure, waste (contaminated soils and water)handling and its disposal, laboratory testing, and other related work. The A-E will prepare the Corrective Action Plans, engineering consultation, reports and other documentation, and consultations with various Naval activities and other Government representatives (local and federa), and make oral, written and visual presentations of findings and recommendations. A-E guides for this contract shall include but not limited to the following: PACNAVFACENGCOM P-74, A-E Guide for Architect-Engineer Firms Performing Services for the Department of the Navy, November 1999; OPNAVINST 5090, 1B-CH2, Environmental and Natural Resources Program Manual, 9 Sep 1999; 40 CFR Parts 280; NAVFAC Guide Specification Section 01525, Safety Requirements; and, NAVFAC Guide Specification Section 01575, Temporary Environmental Controls. The Site Assessments will involve site characterizations and investigations, development of a plan for free product removal, and soil and ground water clean-up in accordance with 40 CFR 280 Subpart F. The assessments shall determine and include, the following: (1) horizontal and vertical extent of the contamination. (2) identity of the contaminants and their concentration. (3) sources of contamination. (4) impact of contamination on the soil, surface and ground water. (5) appropriate remediation technology to prevent the spread of contaminants and to protect human health and the environment. The determination of an appropriate remediation technology will be based upon the factors expressed in 40 CFR 280.65. The following criteria, in relative order of importance, will be used in the evaluation of A-E firms: (1) Professional qualifications of the staff (in-house and consultants). Specialized experience and technical competence of the proposed engineering/technical staff who will perform the work. For relevant jobs listed in Section 8 of Standard Form 255, A-E firm must provide the following for each listed job: (a) relevant professional qualifications of team member (i.e., relevant experience of project team leader, and similar recent projects completed); (b) performance rating; and (c) a reference list of contacts with telephone number. (2) Recent specialized experience of the firm and proposed consultants in the type of work required including experience in energy conservation, pollution prevention, waste reduction, and the use of recovered materials. List projects successfully completed in the last five years. (Do not list more than 10 projects). (3) Capacity to accomplish the work in the required time. Describe how work will be accomplished in the required time, including the composition of the team and availability of the staff. (4) Past performance on contracts with federal and local government agencies and private industry in terms of cost control, quality of work, and compliance with performance schedules. Describe quality control program with demonstrated result of reducing errors and/or omissions (provide name of key person responsible). (5) Location of firm in the general geographical area of the project and knowledge of the locality, including appropriate selection of construction materials and methods; provide, that there is an appropriate number of qulified firms therein for consideration. (6) Volume of work previously awarded to the firm by the Department of Defense during the last 12-month period. (7) Use of small or small disadvantaged or women-owned small business firms shall also be considered. Each firm's past performance and performance rating(s) will be reviewed during the evaluation process and can affect the selection outcome. IN BLOCK 10 OF THE STANDARD FORM (SF) 255 AND AN ADDENDUM THERETO, IF NECESSARY, STATE WHYYOUR FIRM IS SPECIALLY QUALIFIED BASED ON EACH OF THE ABOVE SELECTION EVALUATION CRITERIA. Show the office location where work will be done and describe the experience and location of those who will do the work. Additional information requested of applying firms: Indicate solicitation number in Block 2b, DUNS number (for address listed in Block 3) and TIN number in Block 3. For firms applying with multiple offices, indicate the office that completed each of the projects listed in Block 8 and list which office is under contract for any contracts listed in Block 9. Firm not providing the requested information in the format (i.e., not providing a brief description of the quality control plan, not listing which office of multiple office firms completed projects listed in Block 8, etc.) directed by this synopsis may be negatively evaluated under selection criteria (4). FIRMS MUST BE REGISTERED IN THE DEPARTMENT OF DEFENSE CENTRAL CONTRACTOR REGISTRATION DATABASE TO RECEIVE AWARD. Firms may obtain information on registration and annual confirmation requirements by calling 1-888-227-2423 or via the Internet at http://ccr.edi.disa.mil. The Standard Industrial Classification code for this solicitation is 8711 with a size standard of $2.5 MIL. A-E firms, which meet the requirements described in this announcement, are invited to submit completed SF 254 (unless already on file) and SF 255 to the Officer In Charge of Construction, NAVFACENGCOM Contracts, Marianas, PSC 455, Box 175, FPO AP 96540-2200; Location Address: Building 101, Ground Floor, U.S. Navy Public Works Center Guam Complex, Naval Activities, Guam 96910. Submissions of SFs 254/255 must be received and date/time stamped by the Contracting Officer on or before 29 February 2000 at 4:30 PM in order to be considered. Any submission received after 29 February 2000 at 4:30 PM will not be considered. Firms having a current SF 254 on file with this office may also be considred. This is not a request for proposal. Posted 01/25/00 (W-SN418931). (0025)

Loren Data Corp. http://www.ld.com (SYN# 0007 20000127\C-0002.SOL)


C - Architect and Engineering Services - Construction Index Page