COMMERCE BUSINESS DAILY ISSUE OF JANUARY 27,2000 PSA#2524Officer in Charge of Construction, Naval Facilities Engineering
Command, Contracts Marianas (Guam), PSC 455 Box 175, FPO 96540-2200 C -- ARCHITECT-ENGINEERING SERVICES FOR ASSESSMENT OF UNDERGROUND FUEL
TANKS U-4 AND U-29 AT VARIOUS FUEL DEPARTMENT LOCATIONS,
COMNAVMARIANAS, GUAM, M.I. SOL N62766-00-C-0010 DUE 022900 POC Ms.
Julia Taitano, (671) 339-7467 or FAX (671) 339-4248 Architect-Engineer
(A-E) services are requireed for Environmental Engineering Services
Contract for assessment of underground fuel tanks U-4 and U-29, at
various Fuel Department locations, COMNAVMARIANAS, Guam, M.I. The field
work will include all required surveying, geological, soil boring,
equipment cleaning, sampling, bore hole closure, waste (contaminated
soils and water)handling and its disposal, laboratory testing, and
other related work. The A-E will prepare the Corrective Action Plans,
engineering consultation, reports and other documentation, and
consultations with various Naval activities and other Government
representatives (local and federa), and make oral, written and visual
presentations of findings and recommendations. A-E guides for this
contract shall include but not limited to the following:
PACNAVFACENGCOM P-74, A-E Guide for Architect-Engineer Firms Performing
Services for the Department of the Navy, November 1999; OPNAVINST 5090,
1B-CH2, Environmental and Natural Resources Program Manual, 9 Sep 1999;
40 CFR Parts 280; NAVFAC Guide Specification Section 01525, Safety
Requirements; and, NAVFAC Guide Specification Section 01575, Temporary
Environmental Controls. The Site Assessments will involve site
characterizations and investigations, development of a plan for free
product removal, and soil and ground water clean-up in accordance with
40 CFR 280 Subpart F. The assessments shall determine and include, the
following: (1) horizontal and vertical extent of the contamination. (2)
identity of the contaminants and their concentration. (3) sources of
contamination. (4) impact of contamination on the soil, surface and
ground water. (5) appropriate remediation technology to prevent the
spread of contaminants and to protect human health and the environment.
The determination of an appropriate remediation technology will be
based upon the factors expressed in 40 CFR 280.65. The following
criteria, in relative order of importance, will be used in the
evaluation of A-E firms: (1) Professional qualifications of the staff
(in-house and consultants). Specialized experience and technical
competence of the proposed engineering/technical staff who will perform
the work. For relevant jobs listed in Section 8 of Standard Form 255,
A-E firm must provide the following for each listed job: (a) relevant
professional qualifications of team member (i.e., relevant experience
of project team leader, and similar recent projects completed); (b)
performance rating; and (c) a reference list of contacts with telephone
number. (2) Recent specialized experience of the firm and proposed
consultants in the type of work required including experience in energy
conservation, pollution prevention, waste reduction, and the use of
recovered materials. List projects successfully completed in the last
five years. (Do not list more than 10 projects). (3) Capacity to
accomplish the work in the required time. Describe how work will be
accomplished in the required time, including the composition of the
team and availability of the staff. (4) Past performance on contracts
with federal and local government agencies and private industry in
terms of cost control, quality of work, and compliance with performance
schedules. Describe quality control program with demonstrated result of
reducing errors and/or omissions (provide name of key person
responsible). (5) Location of firm in the general geographical area of
the project and knowledge of the locality, including appropriate
selection of construction materials and methods; provide, that there is
an appropriate number of qulified firms therein for consideration. (6)
Volume of work previously awarded to the firm by the Department of
Defense during the last 12-month period. (7) Use of small or small
disadvantaged or women-owned small business firms shall also be
considered. Each firm's past performance and performance rating(s) will
be reviewed during the evaluation process and can affect the selection
outcome. IN BLOCK 10 OF THE STANDARD FORM (SF) 255 AND AN ADDENDUM
THERETO, IF NECESSARY, STATE WHYYOUR FIRM IS SPECIALLY QUALIFIED BASED
ON EACH OF THE ABOVE SELECTION EVALUATION CRITERIA. Show the office
location where work will be done and describe the experience and
location of those who will do the work. Additional information
requested of applying firms: Indicate solicitation number in Block 2b,
DUNS number (for address listed in Block 3) and TIN number in Block 3.
For firms applying with multiple offices, indicate the office that
completed each of the projects listed in Block 8 and list which office
is under contract for any contracts listed in Block 9. Firm not
providing the requested information in the format (i.e., not providing
a brief description of the quality control plan, not listing which
office of multiple office firms completed projects listed in Block 8,
etc.) directed by this synopsis may be negatively evaluated under
selection criteria (4). FIRMS MUST BE REGISTERED IN THE DEPARTMENT OF
DEFENSE CENTRAL CONTRACTOR REGISTRATION DATABASE TO RECEIVE AWARD.
Firms may obtain information on registration and annual confirmation
requirements by calling 1-888-227-2423 or via the Internet at
http://ccr.edi.disa.mil. The Standard Industrial Classification code
for this solicitation is 8711 with a size standard of $2.5 MIL. A-E
firms, which meet the requirements described in this announcement, are
invited to submit completed SF 254 (unless already on file) and SF 255
to the Officer In Charge of Construction, NAVFACENGCOM Contracts,
Marianas, PSC 455, Box 175, FPO AP 96540-2200; Location Address:
Building 101, Ground Floor, U.S. Navy Public Works Center Guam Complex,
Naval Activities, Guam 96910. Submissions of SFs 254/255 must be
received and date/time stamped by the Contracting Officer on or before
29 February 2000 at 4:30 PM in order to be considered. Any submission
received after 29 February 2000 at 4:30 PM will not be considered.
Firms having a current SF 254 on file with this office may also be
considred. This is not a request for proposal. Posted 01/25/00
(W-SN418931). (0025) Loren Data Corp. http://www.ld.com (SYN# 0007 20000127\C-0002.SOL)